Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials

被引:4
|
作者
Han, Xiaoxuan [1 ]
Zhao, Ruijie [1 ]
Tian, Yong [2 ,5 ]
Li, Yutong [1 ]
Chen, Xu-Wei [1 ]
Ma, Jiping [2 ]
Wang, Weiliang [2 ]
Zhang, Yanfeng [3 ,6 ]
Geng, Song [3 ]
Liu, Menglin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Dept Chem, Shenyang, Peoples R China
[2] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[3] Intelligent Policing Key Lab Sichuan Prov, Luzhou, Peoples R China
[4] Rizhao Custom, Rizhao, Peoples R China
[5] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[6] Intelligent Policing Key Lab Sichuan Prov, Luzhou 646000, Peoples R China
基金
中国国家自然科学基金;
关键词
bisphenols; building material; high performance-liquid chromatography; separation; ultraviolet detector; SOLID-PHASE EXTRACTION; UNITED-STATES; WATER SAMPLES; INDOOR DUST; ANALOGS; EXPOSURE; JAPAN; KOREA;
D O I
10.1002/jssc.202300006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100-5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma
    Ahmadi-Jouibari, Toraj
    Fattahi, Nazir
    Shamsipur, Mojtaba
    Pirsaheb, Meghdad
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 85 : 14 - 20
  • [2] A simple, sensitive high-performance liquid chromatography-ultraviolet method for the quantification of concentration and steady-state pharmacokinetics of itraconazole and hydroxyitraconazole
    Miura, M.
    Takahashi, N.
    Nara, M.
    Fujishima, N.
    Kagaya, H.
    Kameoka, Y.
    Saitoh, H.
    Tagawa, H.
    Sawada, K.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 432 - 439
  • [3] High performance liquid chromatography-ultraviolet photometric detection for the simultaneous determination of cephalosporins in human urine and bovine milk
    Cai Yu'e
    Cai Yaqi
    Mou Shifen
    Lu Yiqiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (06) : 745 - 748
  • [4] Quantitation of antioxidants in water samples using ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection
    Sobhi, Hamid Reza
    Kashtiaray, Amir
    Farahani, Hadi
    Farahani, Mohammad Reza
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 77 - 82
  • [5] SIMPLE MEASUREMENT OF CAPTOPRIL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    KLEIN, J
    COLIN, P
    SCHERER, E
    LEVY, M
    KOREN, G
    THERAPEUTIC DRUG MONITORING, 1990, 12 (01) : 105 - 110
  • [6] Determination of chloramphenicol and three tetracyclines by solid phase extraction and high performance liquid chromatography-ultraviolet detection
    Liu Hong
    Zhang Guo-Ping
    Liu Cong-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 315 - 319
  • [7] Simultaneous determination of tricarboxylic acid cycle metabolites by high-performance liquid chromatography with ultraviolet detection
    Shurubor, Yevgeniya I.
    Cooper, Arthur J. L.
    Isakova, Elena P.
    Deryabina, Yulia I.
    Beal, M. Flint
    Krasnikov, Boris F.
    ANALYTICAL BIOCHEMISTRY, 2016, 503 : 8 - 10
  • [8] Simultaneous determination of five systemic azoles in plasma by high-performance liquid chromatography with ultraviolet detection
    Gordien, Jean-Baptiste
    Pigneux, Arnaud
    Vigouroux, Stephane
    Tabrizi, Reza
    Accoceberry, Isabelle
    Bernadou, Jean-Marc
    Rouault, Audrey
    Saux, Marie-Claude
    Breilh, Dominique
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 932 - 938
  • [9] Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection
    de Andrade, MCC
    Di Marco, GS
    Felipe, CR
    Alfieri, F
    Júnior, HTS
    Pestana, JOM
    Casarini, DE
    TRANSPLANT INTERNATIONAL, 2005, 18 (03) : 354 - 359
  • [10] Trace determination of phthalate esters in river water by solvent sublation followed by high-performance liquid chromatography-ultraviolet detection
    Guo, Liu
    Dong, Huiru
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (05) : 357 - 365