Use of some amino acid potentiometric biosensors as detectors in ion chromatography

被引:7
作者
Isildak, Omer [1 ]
Gunes, Gazi [1 ]
Ozbek, Oguz [2 ]
机构
[1] Tokat Gaziosmanpasa Univ, Fac Sci & Arts, Dept Chem, TR-60250 Tokat, Turkiye
[2] Zonguldak Bulent Ecevit Univ, Sci & Technol Applicat & Res Ctr, TR-67600 Zonguldak, Turkiye
关键词
Amino acid; Potentiometry; Ion chromatography; Biosensor; SELECTIVE ELECTRODES; ELECTROPHORESIS; CAPILLARY;
D O I
10.1007/s11696-023-02706-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, composite amino acid-sensitive potentiometric biosensors in microsizes were prepared and used as detectors in ion chromatography (IC). First, ammonium-selective electrodes were prepared, and their potentiometric behavior was tested. Then, the L-amino acid oxidase (L-AAO) enzyme was attached to the surface of the ammonium-selective potentiometric electrodes with glutaraldehyde crosslinker. The potentiometric behavior of the prepared biosensors against different L-amino acids was investigated. The biosensors exhibited ideal potentiometric responses to some of the L-amino acids. Biosensors with the ideal potentiometric behavior were placed in the moving medium flow cell together with the Ag/AgCl reference electrode. This flow cell was placed at the exit of the column in the ion chromatographic system, allowing it to function as a detector. The chromatograms were obtained by injecting free amino acids into the prepared chromatography-potentiometry hybrid system. The obtained results showed that the prepared biosensors can be used as detectors in chromatography and as detectors in the determination of free amino acids.
引用
收藏
页码:3317 / 3325
页数:9
相关论文
共 25 条
[1]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[2]   Analytical strategies for the determination of amino acids: Past, present and future trends [J].
Ferre, Sabrina ;
Gonzalez-Ruiz, Victor ;
Guillarme, Davy ;
Rudaz, Serge .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1132
[3]   Gas Chromatography-Mass Spectrometry Method for the Determination of Free Amino Acids as Their Dimethyl-tert-butylsilyl (TBDMS) Derivatives in Animal Source Food [J].
Jimenez-Martin, Estefania ;
Ruiz, Jorge ;
Perez-Palacios, Trinidad ;
Silva, Antonio ;
Antequera, Teresa .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (10) :2456-2463
[4]   Accurate and efficient amino acid analysis for protein quantification using hydrophilic interaction chromatography coupled tandem mass spectrometry [J].
Kambhampati, Shrikaar ;
Li, Jia ;
Evans, Bradley S. ;
Allen, Doug K. .
PLANT METHODS, 2019, 15 (1)
[5]   Simple extraction procedure for free amino acids determination in selected gluten-free flour samples [J].
Kowalska, Sylwia ;
Szlyk, Edward ;
Jastrzebska, Aneta .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2022, 248 (02) :507-517
[6]   Rapid determination of amino acids by capillary electrophoresis without preliminary derivatization [J].
Manaenkov, OV ;
Sidorov, AI ;
Sul'man, EM .
JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (10) :979-982
[7]  
Mehrotra Parikha, 2016, J Oral Biol Craniofac Res, V6, P153, DOI 10.1016/j.jobcr.2015.12.002
[8]   Diagnostic biosensors in medicine - A review [J].
Metkar, Sanjay Kisan ;
Girigoswami, Koyeli .
BIOCATALYSIS AND AGRICULTURAL BIOTECHNOLOGY, 2019, 17 :271-283
[9]   Potentiometric PVC Membrane Sensor for the Determination of Anti-Epileptic Drug Levetiracetam in Pharmaceutical Formulations [J].
Ozbek, Oguz ;
Isildak, Omer .
CHEMISTRYSELECT, 2022, 7 (03)
[10]   A potentiometric sensor for the determination of potassium in different baby follow-on milk, water, juice and pharmaceutical samples [J].
Ozbek, Oguz .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 115