Effects of temperature and humidity ratio on the performance of desiccant dehumidification system under low-temperature regeneration

被引:6
作者
Yu, Hao [1 ]
Seo, Sang Won [1 ]
Miksik, Frantisek [2 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
Ng, Kim Choon [3 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] King Abdullah Univ Sci & Technol KAUST, Water Desalinat & Reuse Ctr WDRC, Thuwal 239556900, Saudi Arabia
关键词
Adsorption; Dehumidification; Desiccant; Low-temperature regeneration; Performance analysis; WATER-VAPOR; LIQUID DESICCANT; COOLING SYSTEM; SODIUM-SALT; SILICA-GEL; WASTE HEAT; ADSORPTION; ENERGY; ENVIRONMENT; SORBENTS;
D O I
10.1007/s10973-022-11368-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
The desiccant dehumidification system can separate the latent heat and sensible heat in the air-conditioning system and achieve energy savings by removing latent heat. Industrial waste heat and renewable energy could be utilized in desiccant dehumidification systems, where the desorption process can be performed below 70 degrees C. The vapor pressure and temperature of the regenerating air dictate the desorption process corresponding to the isotherm properties. This study has focused on the effects of various temperatures and humidity ratios of regeneration air on the performance of a desiccant dehumidifier using a polymer as an adsorbent. Experiments were performed using the regeneration air with the humidity ratios of 0.005 kg kg(-1), 0.010 kg kg(-1), 0.015 kg kg(-1), and 0.020 kg kg(-1), while the air temperatures were varied from 40 degrees C to 70 degrees C. The evaluation of this study employs the adsorption/desorption amount, average moisture removal capacity, and latent energy ratio (LER) of the regeneration process as key performance indexes. At the regeneration temperature of 68 degrees C, the peak desorption amount at the humidity ratio of 0.005 kg kg(-1) and 0.010 kg kg(-1) both reached 0.011 kg kg(-1). The results indicated that the higher desorption temperature led to a higher desorption amount. Besides, with the increased desorption temperature, the average moisture removal capacity increases. In contrast, the high humidity ratio of regeneration air resulted in a weak dehumidification ability. Lower regeneration temperature was difficult to apply to regenerate the polymer-based desiccant under a high-humidity-ratio atmosphere. To attain a high LER, a lower humidity ratio of dry air and regeneration temperature was preferred. The regeneration air with a humidity ratio of 0.020 kg kg(-1) is not suitable to apply in the dehumidification system in the temperature range of 40-70 degrees C.
引用
收藏
页码:3045 / 3058
页数:14
相关论文
共 50 条
  • [31] ENERGY ANALYSIS OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH VARIABLE TEMPERATURE AND HUMIDITY DESIGN
    Xu, Guiquan
    Pei, Qingqing
    Li, Fangyan
    Liao, Zhu
    Chen, Yujian
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1957 - 1964
  • [32] Photo-crosslinked nanofibrous membranes as advanced low-temperature regenerative desiccant
    Yao, Ye
    Dai, Li
    Jiang, Fengjing
    POLYMER TESTING, 2019, 78
  • [33] Experimental and numerical study on low temperature regeneration desiccant wheel: Parameter analysis with a comprehensive energy index
    Su, Xing
    Tian, Shaochen
    Shao, Xiaolu
    Zhang, Xu
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 120 : 237 - 247
  • [34] Performance analysis of a hybrid air-conditioning system dehumidified by liquid desiccant with low temperature and low concentration
    Chen, Yao
    Yin, Yonggao
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2014, 77 : 91 - 102
  • [35] Effects of temperature and humidity on the performance of a PECH polymer coated SAW sensor
    Pan, Yong
    Zhang, Lin
    Cao, Bingqing
    Xue, Xufeng
    Liu, Weiwei
    Zhang, Caihong
    Wang, Wen
    RSC ADVANCES, 2020, 10 (31) : 18099 - 18106
  • [36] The performance of a temperature cascaded cogeneration system producing steam, cooling and dehumidification
    Myat, Aung
    Thu, Kyaw
    Kim, Young-Deuk
    Choon, Ng Kim
    DESALINATION AND WATER TREATMENT, 2013, 51 (7-9) : 1915 - 1921
  • [37] Efficient removal of CO2 from indoor air using a polyethyleneimine-impregnated resin and its low-temperature regeneration
    Wang, Wenjing
    Liu, Fenglei
    Zhang, Qianxin
    Yu, Gang
    Deng, Shubo
    CHEMICAL ENGINEERING JOURNAL, 2020, 399
  • [38] The performance of a desiccant wheel air conditioning system with high-temperature chilled water from natural cold source
    Chen, Liu
    Tan, Yikun
    RENEWABLE ENERGY, 2020, 146 : 2142 - 2157
  • [39] Performance study of a constant temperature and humidity air-conditioning system with temperature and humidity independent control device
    Zhang, X. J.
    Xiao, F.
    Li, S.
    ENERGY AND BUILDINGS, 2012, 49 : 640 - 646
  • [40] Detailed experimental analysis of the energy performance of a desiccant wheel activated at low temperature
    Comino, F.
    Taboas, F.
    Peci, F.
    Ruiz de Adana, M.
    APPLIED THERMAL ENGINEERING, 2020, 178 (178)