Effects of temperature and humidity ratio on the performance of desiccant dehumidification system under low-temperature regeneration

被引:6
作者
Yu, Hao [1 ]
Seo, Sang Won [1 ]
Miksik, Frantisek [2 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
Ng, Kim Choon [3 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] King Abdullah Univ Sci & Technol KAUST, Water Desalinat & Reuse Ctr WDRC, Thuwal 239556900, Saudi Arabia
关键词
Adsorption; Dehumidification; Desiccant; Low-temperature regeneration; Performance analysis; WATER-VAPOR; LIQUID DESICCANT; COOLING SYSTEM; SODIUM-SALT; SILICA-GEL; WASTE HEAT; ADSORPTION; ENERGY; ENVIRONMENT; SORBENTS;
D O I
10.1007/s10973-022-11368-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
The desiccant dehumidification system can separate the latent heat and sensible heat in the air-conditioning system and achieve energy savings by removing latent heat. Industrial waste heat and renewable energy could be utilized in desiccant dehumidification systems, where the desorption process can be performed below 70 degrees C. The vapor pressure and temperature of the regenerating air dictate the desorption process corresponding to the isotherm properties. This study has focused on the effects of various temperatures and humidity ratios of regeneration air on the performance of a desiccant dehumidifier using a polymer as an adsorbent. Experiments were performed using the regeneration air with the humidity ratios of 0.005 kg kg(-1), 0.010 kg kg(-1), 0.015 kg kg(-1), and 0.020 kg kg(-1), while the air temperatures were varied from 40 degrees C to 70 degrees C. The evaluation of this study employs the adsorption/desorption amount, average moisture removal capacity, and latent energy ratio (LER) of the regeneration process as key performance indexes. At the regeneration temperature of 68 degrees C, the peak desorption amount at the humidity ratio of 0.005 kg kg(-1) and 0.010 kg kg(-1) both reached 0.011 kg kg(-1). The results indicated that the higher desorption temperature led to a higher desorption amount. Besides, with the increased desorption temperature, the average moisture removal capacity increases. In contrast, the high humidity ratio of regeneration air resulted in a weak dehumidification ability. Lower regeneration temperature was difficult to apply to regenerate the polymer-based desiccant under a high-humidity-ratio atmosphere. To attain a high LER, a lower humidity ratio of dry air and regeneration temperature was preferred. The regeneration air with a humidity ratio of 0.020 kg kg(-1) is not suitable to apply in the dehumidification system in the temperature range of 40-70 degrees C.
引用
收藏
页码:3045 / 3058
页数:14
相关论文
共 50 条
  • [21] Performance comparison of different working pairs on a liquid desiccant dehumidification system with vacuum regeneration
    Cheng X.
    Yin Y.
    Che C.
    Huagong Xuebao/CIESC Journal, 2023, 74 (08): : 3494 - 3501
  • [22] Performance of a temperature and humidity independent control air-conditioning system based on liquid desiccant for industrial environments
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Qinling
    Zhang, Tao
    ENERGY AND BUILDINGS, 2020, 214
  • [23] Polyamide 6-LiCl nanofibrous membrane as low-temperature regenerative desiccant with improved stability
    Jiang, Fengjing
    Dai, Li
    Yao, Ye
    NANOTECHNOLOGY, 2018, 29 (18)
  • [24] Hybrid liquid desiccant air-conditioning system combined with marine aerosol removal driven by low-temperature heat source
    Dai, Yuze
    Liu, Feng
    Sui, Jun
    Wang, Dandan
    Han, Wei
    Jin, Hongguang
    APPLIED ENERGY, 2020, 275
  • [25] Research on temperature and humidity independent control system based on liquid desiccant
    Zhang Yinghua
    Tian Yuan
    Huang Zhian
    Zhao Qian
    Gao Yukun
    2013 FOURTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND ENGINEERING APPLICATIONS, 2013, : 515 - 518
  • [26] A review of photovoltaic thermal (PV/T) heat utilisation with low temperature desiccant cooling and dehumidification
    Guo, Jinyi
    Lin, Simao
    Bilbao, Jose I.
    White, Stephen D.
    Sproul, Alistair B.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 1 - 14
  • [27] Research of Low-temperature Regeneration of Waste EPDM
    Wang, Chuansheng
    Xie, Qingguo
    Bian, Huiguang
    PROGRESS IN POLYMER PROCESSING, 2012, 501 : 311 - 315
  • [28] Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature
    Ruivo, Celestino R.
    Goldsworthy, Mark
    Intini, Manuel
    ENERGY, 2014, 68 : 765 - 772
  • [29] Experimental study on combined low temperature regeneration of liquid desiccant and evaporative cooling by ultrasonic atomization
    Arun, B. S.
    Mariappan, V
    Maisotsenko, Valeriy
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 : 100 - 109
  • [30] Cyclic steady state performance of adsorption chiller with low regeneration temperature zeolite
    Qian, Suxin
    Gluesenkamp, Kyle
    Hwang, Yunho
    Radermacher, Reinhard
    Chun, Ho-Hwan