Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture

被引:1
作者
Kim, Jae Kwang [1 ]
Shin, Young Ho [1 ]
Kim, Minsoo [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Orthoped Surg, 88,Olymp Rd 43 Gil, Seoul 05505, South Korea
关键词
Volar locking plate; Distal radius fracture; Flexor tendon attrition; Ultrasound; HARDWARE REMOVAL; FIXATION; POSITION; RUPTURE; WRIST; TILT;
D O I
10.1007/s00402-022-04499-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction We classified the contact configuration between the volar prominence of volar locking plate (VLP) and flexor pollicis longus (FPL) tendon using ultrasound (US) into indentation contact and smooth contact, and investigated whether the contact configuration is associated with the flexor tendon attrition. Materials and methods Ninety-four patients who underwent VLP removal were included in this study. We assessed pain using visual analogue scale, grip strength, and Disabilities of the Arm, Shoulder and Hand score for clinical evaluations, radial inclination, palmar tilt, ulnar variance, and Soong classification for radiological evaluations, and contact configuration using US at 1 year after VLP fixation. After these evaluations, we removed the VLP with observation for the presence of fibrillation or wear of FPL tendon substance. Subsequently, we classified the patients into either of FPL attrition and FPL intact group. Results Twenty-eight patients had indentation contact configuration and 66 patients had smooth contact configuration. The kappa value for inter-observer reliability for the contact configuration was 0.78. Twelve patients were included in the FPL attrition group and 82 in the FPL intact group. There was no significant difference in clinical outcomes and Soong classification between the groups. However, palmar tilt of the flexor tendon attrition group was significantly lower than that of the flexor tendon intact group and the FPL attrition group showed significantly higher indentation contact configuration rate than the FPL intact group. FPL tendon attrition was diagnosed using the contact configuration on US with a sensitivity of 100% and specificity of 80%. Conclusion This study demonstrated that FPL tendon attrition was significantly associated with indentation contact on US with high sensitivity. Therefore, we recommend selective implant removal in patients with indentation contact configuration.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 50 条
  • [21] Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture
    Cho, Chul-Hyun
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    CLINICS IN ORTHOPEDIC SURGERY, 2012, 4 (04) : 325 - 328
  • [22] The Effect of Plate Design on the Flexor Pollicis Longus Tendon After Volar Locked Plating of Distal Radial Fractures
    Stepan, Jeffrey G.
    Marshall, Danielle C.
    Wessel, Lauren E.
    Endo, Yoshimi
    Miller, Theodore T.
    Sacks, Hayley A.
    Weiland, Andrew J.
    Fufa, Duretti T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (17) : 1586 - 1592
  • [23] Transverse ultrasound assessment of the flexor pollicis longus tendon movement on the distal radius during wrist and finger motion in distal radius fracture with volar plating
    Mitsuhiko Nanno
    Norie Kodera
    Yuji Tomori
    Shinro Takai
    Journal of Medical Ultrasonics, 2016, 43 : 29 - 36
  • [24] Late rupture of Flexor Pollicis Longus tendon 10 years after volar buttress plate fixation of a distal radius fracture : A case report
    Monda, Maureen K.
    Ellis, Allun
    Karmani, Shuaib
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (04): : 549 - 551
  • [25] Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study
    Sato, Kotaro
    Kikuchi, Yuki
    Mimata, Yoshikuni
    Murakami, Kenya
    Takahashi, Gaku
    Doita, Minoru
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2019, 20 (01)
  • [26] How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicus longus tendon: a biomechanical investigation
    Matityahu, A. M.
    Lapalme, S. N.
    Seth, A.
    Marmor, M. T.
    Buckley, J. M.
    Lattanza, L. L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (02) : 144 - 150
  • [27] Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report
    Klug, Raymond A.
    Press, Cyrus M.
    Gonzalez, Mark H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 984 - 988
  • [28] Outcomes of Flexor Pollicis Longus Reconstruction for Volar Plate Related Ruptures
    Macken, Arno A.
    Lans, Jonathan
    Ozkan, Sezai
    Kramer, Simon
    Jupiter, Jesse B.
    Chen, Neal C.
    JOURNAL OF HAND AND MICROSURGERY, 2023, 15 (03) : 212 - 218
  • [29] Reducing the risk of flexor pollicis longus tendon rupture after volar plate fixation for distal radius fractures: validation of the tendon irritation test
    Suganuma S.
    Tada K.
    Tsuchiya H.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (8) : 1425 - 1429
  • [30] Rupture of the Flexor Pollicis Longus Tendon Involved between the Radial Shaft and the Volar Locking Plate
    Hiraishi, Yuri
    Kimura, Hiroo
    Suzuki, Taku
    Matsumura, Noboru
    Iwamoto, Takuji
    Matsumoto, Morio
    Nakamura, Masaya
    JOURNAL OF WRIST SURGERY, 2023, 12 (06) : 540 - 542