Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture

被引:1
|
作者
Kim, Jae Kwang [1 ]
Shin, Young Ho [1 ]
Kim, Minsoo [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Orthoped Surg, 88,Olymp Rd 43 Gil, Seoul 05505, South Korea
关键词
Volar locking plate; Distal radius fracture; Flexor tendon attrition; Ultrasound; HARDWARE REMOVAL; FIXATION; POSITION; RUPTURE; WRIST; TILT;
D O I
10.1007/s00402-022-04499-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction We classified the contact configuration between the volar prominence of volar locking plate (VLP) and flexor pollicis longus (FPL) tendon using ultrasound (US) into indentation contact and smooth contact, and investigated whether the contact configuration is associated with the flexor tendon attrition. Materials and methods Ninety-four patients who underwent VLP removal were included in this study. We assessed pain using visual analogue scale, grip strength, and Disabilities of the Arm, Shoulder and Hand score for clinical evaluations, radial inclination, palmar tilt, ulnar variance, and Soong classification for radiological evaluations, and contact configuration using US at 1 year after VLP fixation. After these evaluations, we removed the VLP with observation for the presence of fibrillation or wear of FPL tendon substance. Subsequently, we classified the patients into either of FPL attrition and FPL intact group. Results Twenty-eight patients had indentation contact configuration and 66 patients had smooth contact configuration. The kappa value for inter-observer reliability for the contact configuration was 0.78. Twelve patients were included in the FPL attrition group and 82 in the FPL intact group. There was no significant difference in clinical outcomes and Soong classification between the groups. However, palmar tilt of the flexor tendon attrition group was significantly lower than that of the flexor tendon intact group and the FPL attrition group showed significantly higher indentation contact configuration rate than the FPL intact group. FPL tendon attrition was diagnosed using the contact configuration on US with a sensitivity of 100% and specificity of 80%. Conclusion This study demonstrated that FPL tendon attrition was significantly associated with indentation contact on US with high sensitivity. Therefore, we recommend selective implant removal in patients with indentation contact configuration.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 50 条
  • [1] Ultrasonographic evaluation of contact configuration between flexor pollicis longus tendon and the volar prominence of volar plate in patients with distal radius fracture
    Jae Kwang Kim
    Young Ho Shin
    Minsoo Kim
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1103 - 1108
  • [2] Ultrasonographic movement of the flexor pollicis longus tendon before and after removal of a volar plate for the distal radius fracture
    Nanno, Mitsuhiko
    Kodera, Norie
    Tomori, Yuji
    Takai, Shinro
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01):
  • [3] Evaluation of Flexor Pollicis Longus Tendon Rupture after Treatment of Distal Radius Fracture with the Volar Plate
    Yamak, Kamil
    Karahan, Huseyin Gokhan
    Karatan, Berrak
    Kayali, Cemil
    Altay, Taskin
    JOURNAL OF WRIST SURGERY, 2020, 9 (03) : 219 - 224
  • [4] Positioning of a Volar Locking Plate with a Central Flexor Pollicis Longus Tendon Notch in Distal Radius Fractures
    Kaiser, Peter
    Gruber, Hannes
    Loth, Fanny
    Schmidle, Gernot
    Arora, Rohit
    Gabl, Markus
    JOURNAL OF WRIST SURGERY, 2019, 8 (06) : 482 - 488
  • [5] Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius
    Uemura, Takuya
    Okano, Tadashi
    Onode, Ema
    Yokoi, Takuya
    Shintani, Kosuke
    Okada, Mitsuhiro
    Nakamura, Hiroaki
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (04) : 647 - 651
  • [6] Effect of Distal Radius Volar Plate Position on Contact Pressure Between the Flexor Pollicis Longus Tendon and the Distal Plate Edge
    Tanaka, Yoshitaka
    Aoki, Mitsuhiro
    Izumi, Tomoki
    Fujimiya, Mineko
    Yamashita, Toshihiko
    Imai, Tomohito
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (11): : 1790 - 1797
  • [7] Changes in Distance Between the Flexor Pollicis Longus Tendon and Volar Locking Plate: An Ultrasonographic Study
    Oura, Keiichiro
    Matsumura, Nobumasa
    Noguchi, Ryosuke
    Fujiwara, Tatsuji
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (01): : 99e1 - 99e5
  • [8] Ultrasonographic evaluation of the distance between the flexor pollicis longus tendon and volar prominence of the plate as a function of volar plate positioning and pronator quadratus repair - A cadaver study
    Goorens, C. K.
    Van Royen, K.
    Grijseels, S.
    Provyn, S.
    De Mey, J.
    Scheerlinck, T.
    Goubau, J. F.
    HAND SURGERY & REHABILITATION, 2018, 37 (03) : 171 - 174
  • [9] Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate
    Wurtzel, Caroline N. Wolfe
    Burns, Geoffrey T.
    Zhu, Andy F.
    Ozer, Kagan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (12): : 996 - 1002
  • [10] Ultrasonic Evaluation of the Flexor Pollicis Longus Tendon Following Volar Plate Fixation for Distal Radius Fractures
    Kara, Adnan
    Celik, Haluk
    Bankaoglu, Mujdat
    Oc, Yunus
    Bulbul, Murat
    Sugun, Tahir Sadik
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (03): : 374 - 380