Comparative experimental study of the biomechanical properties of retrograde tibial nailing and distal tibia plate in distal tibia fracture

被引:0
作者
Lin, Xuping [1 ,2 ]
Zhang, Cong [2 ]
Yang, Yanfang [3 ]
Yang, Wencheng [1 ]
Wang, Xiaomeng [1 ]
Lu, Haichuan [1 ]
Liu, Qingjun [2 ]
机构
[1] Fujian Med Univ, Dept Spinal Surg, Longyan Affiliated Hosp 1, Longyan, Peoples R China
[2] Xiamen Univ, Dept Orthoped Surg, Affiliated Dongnan Hosp, Zhangzhou, Peoples R China
[3] Fujian Med Univ, Shengli Clin Med Coll, Fuzhou, Peoples R China
关键词
distal tibia fracture; internal fixation; retrograde tibial nailing; distal tibia plate; biomechanics; FIXATION; OSTEOSYNTHESIS;
D O I
10.3389/fbioe.2024.1322043
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: A biomechanical comparative analysis was conducted to evaluate the retrograde tibial nailing (RTN) and distal tibia plate techniques for the treatment of distal tibia fractures.Methods: Fourteen fresh adult tibia specimens were selected, consisting of seven males and seven females aged 34-55 years. The specimens were randomly divided into two groups (Group A and Group B) using a numerical table method, with seven specimens in each group. Group A underwent internal fixation of distal tibial fractures using RTN, while Group B received internal fixation using a plate. The axial compression properties of the specimens were tested in the neutral positions under pressures of 100, 200, 300, 400, and 500 N. Additionally, the torsional resistance of the two groups was assessed by subjecting the specimens to torques of 1.0, 2.0, 3.0, 4.0, and 5.0 N m.Results: At pressures of 400 and 500 N, the axial compression displacement in Group A (1.11 +/- 0.06, 1.24 +/- 0.05) mm was significantly smaller than that in Group B (1.21 +/- 0.08, 1.37 +/- 0.11) mm (p = 0.023, 0.019). Moreover, at a pressure of 500 N, the axial compression stiffness in Group A (389.24 +/- 17.79) N/mm was significantly higher than that of the control group (362.37 +/- 14.44) N/mm (p = 0.010). When subjected to torques of 4 and 5 N m, the torsion angle in Group A (2.97 degrees +/- 0.23 degrees, 3.41 degrees +/- 0.17 degrees) was significantly smaller compared to Group B (3.31 degrees +/- 0.28 degrees, 3.76 degrees +/- 0.20 degrees) (p = 0.035, 0.004). Furthermore, at a torque of 5 N m, the torsional stiffness in Group A (1.48 +/- 0.07) N m/degrees was significantly higher than that in Group B (1.36 +/- 0.06) N center dot m/degrees (p = 0.003).Conclusion: The results obtained from the study demonstrate that the biomechanical performance of RTN outperforms that of the distal tibial plate, providing valuable biomechanical data to support the clinical implementation of RTN.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis
    Cunningham, Daniel J.
    Lawrence, Joshua E.
    Kovvur, Murali
    Turner, Kristin E.
    Oppizzi, Giovanni
    Xu, Dali
    Zhang, Li-Qun
    Johnson, Daniel J.
    Mittwede, Peter
    Sepehri, Aresh
    Brand, Jordan
    O'Toole, Robert, V
    Gage, Mark J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [42] Unlocked and locked elastic stable intramedullary nailing in an ovine tibia fracture model: A biomechanical study
    Berger, Leopold
    Fischerauer, Stefan
    Weiss, Barbara
    Celarek, Anna
    Castellani, Christoph
    Weinberg, Annelie-Martina
    Tschegg, Elmar
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 40 : 267 - 274
  • [43] Entrapment of the anterior tibial artery in a distal tibial fracture after intramedullary nailing
    Labler, L
    Wedler, V
    Mica, L
    Trentz, O
    UNFALLCHIRURG, 2006, 109 (02): : 156 - 159
  • [44] Entrapment of the anterior tibial artery in a distal tibial fracture after intramedullary nailing
    Labler L.
    Wedler V.
    Mica L.
    Trentz O.
    Der Unfallchirurg, 2006, 109 (2): : 156 - 159
  • [45] A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures
    Daolagupu, Arup K.
    Mudgal, Ashwani
    Agarwala, Vikash
    Dutta, Kaushik K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (03) : 292 - 298
  • [46] Reconstruction of bone defect with allograft and retrograde intramedullary nail for distal tibia osteosarcoma
    Xu, Leilei
    Zhou, Jin
    Wang, Zhou
    Xiong, Jin
    Qiu, Yong
    Wang, Shoufeng
    FOOT AND ANKLE SURGERY, 2018, 24 (02) : 149 - 153
  • [47] Treatment of distal tibia end fractures by minimally invasive plate osteosynthesis
    Quang-Tri Le
    Ngoc-Thanh Do
    Minh-Hoang Nguyen
    Huu-Hung Phan
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 : 33 - 36
  • [48] Finite element analysis of the stability of AO/OTA 43-C1 type distal tibial fractures treated with distal tibia medial anatomic plate versus anterolateral anatomic plate
    Oken, O. Fuad
    Yildirim, A. Ozgur
    Asilturk, Mehmet
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (05) : 404 - 408
  • [49] Reconstruction of distal tibia fractures using a posterolateral approach and a blade plate
    Sheerin, DV
    Turen, CH
    Nascone, JW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (04) : 247 - 252
  • [50] Factors influencing interlocking screw failure in unreamed small diameter nails - A biomechanical study using a distal tibia fracture model
    Weninger, Patrick
    Schueller, Michael
    Jamek, Michael
    Stanzl-Tschegg, Stefanie
    Redl, Heinz
    Tschegg, Elmar K.
    CLINICAL BIOMECHANICS, 2009, 24 (04) : 379 - 384