Clinical and radiological outcomes and analysis of failures of modular revisions stems at long-term follow-up: a systematic review and meta-analysis

被引:0
作者
Saracco, Michela [1 ,4 ]
Ciriello, Vincenzo [2 ]
Fidanza, Andrea [3 ]
Logroscino, Giandomenico [3 ]
机构
[1] ASL Napoli 2 Nord, San Giovanni Dio Hosp, Dept Orthopaed & Trauma, Naples, Italy
[2] ASO S Croce & Carle, Dept Orthopaed & Trauma, Cuneo, Italy
[3] Univ Aquila, Dept Life Hlth & Environm Sci, Mininvas Orthopaed Surg, Laquila, Italy
[4] ASL Napoli 2 Nord, San Giovanni Dio Hosp, Dept Orthopaed & Trauma, Via Domenico Pirozzi, I-80020 Naples, Italy
来源
ANNALS OF JOINT | 2024年 / 9卷
关键词
Hip revision arthroplasty; modular revision stem; modularity; systematic review; TOTAL HIP-ARTHROPLASTY; FEMORAL REVISION; TITANIUM STEM; PROJECTIONS; KNEE; REPLACEMENT; PROSTHESIS; FIXATION;
D O I
10.21037/aoj-23-32
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Increasingly hip replacements at young age exposes the patient to an increased risk of failure of the implant over the years. In case of failure, revision specific stems were designed to overcome bone loss. Modularity of these devices is an important resource for the surgeon as they allow the new implant to be better adapted to the patient's anatomy. The purpose of this systematic review is to provide data about the outcome at long-term follow-up (>8 years) of hip modular revision femoral stems. Methods: This systematic review and meta-analysis were conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement guidelines. PubMed and Google Scholar databases were systematically and independently searched, according to the inclusion and exclusion criteria. Two reviewers performed the data extraction independently. In case of disagreement, the senior authors were sought to resolve the divergences. Quality of the involved studies was evaluated with National Institute for Health and Care Excellence (NICE) guidelines (eight-item list) and the Newcastle-Ottawa scale (NOS). Primary and secondary outcomes were evaluated. The statistical analysis of this meta-analysis was performed by using Excel Microsoft and the software STATA.Results: The primary outcome was the re-revision rate of modular revision stems at long-term follow-up. It ranged from 1.4% to 45.6%: random effect pooled estimate was 5.5% [95% confidence interval (CI): 4% to 7%], with a I2 of 12.3% (P=0.332). Mean Harris Hip Score (HHS) was 83 [min: 79; max: 87.6; standard deviation (SD): 3.55]. Secondary evaluated outcomes were: subsidence >5 mm, rate of periprosthetic infection or fractures (intra -and post-operative) and dislocations. The mean value for the NICE tool was 5.5 (SD: 1.13) and 7.3 (SD: 0.79) for the NOS tool. The survival rate was >90% at long-term follow-up (min: 60%; max: 97%).Conclusions: The modular femoral revision stems have demonstrated good long-term reliability and efficacy. This meta-analysis demonstrates that the re-revision rate after 8 years of follow-up is low and 90% of the implants did not fail.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 35 条
  • [1] Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty
    Abdel, Matthew P.
    Cottino, Umberto
    Larson, Dirk R.
    Hanssen, Arlen D.
    Lewallen, David G.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (10) : 873 - 881
  • [2] [Anonymous], RIAP REGISTRO ITALIA
  • [3] [Anonymous], HOME NATL JOINT REGI
  • [4] Clinical experience in femoral revision with the modular Profemur R stem
    Artiaco, Stefano
    Boggio, Frediano
    Titolo, Paolo
    Zoccola, Kristjian
    Bianchi, Pasquale
    Bellomo, Franco
    [J]. HIP INTERNATIONAL, 2011, 21 (01) : 39 - 42
  • [5] FRETTING CORROSION ACCELERATES CREVICE CORROSION OF MODULAR HIP TAPERS
    BROWN, SA
    FLEMMING, CAC
    KAWALEC, JS
    PLACKO, HE
    VASSAUX, C
    MERRITT, K
    PAYER, JH
    KRAAY, MJ
    [J]. JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) : 19 - 26
  • [6] Efe Turgay, 2011, J Arthroplasty, V26, DOI 10.1016/j.arth.2010.05.020
  • [7] Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors
    Falkenberg, Adrian
    Biller, Sara
    Morlock, Michael M.
    Huber, Gerd
    [J]. JOURNAL OF BIOMECHANICS, 2020, 98 (98)
  • [8] Hooper G, 2014, NEW ZEAL MED J, V127, P82
  • [9] The S-ROM hydroxyapatite proximally-coated modular femoral stem in revision hip replacement RESULTS OF 397 HIPS AT A MINIMUM TEN-YEAR FOLLOW-UP
    Imbuldeniya, A. M.
    Walter, W. K.
    Zicat, B. A.
    Walter, W. L.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (06) : 730 - 736
  • [10] Revision Hip Arthroplasty with A Modular Cementless Stem: Mid-Term Follow Up
    Jibodh, Stefan R.
    Schwarzkopf, Ran
    Anthony, Shawn G.
    Malchau, Henrik
    Dempsey, Kyle E.
    Estok, Daniel M., II
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (07) : 1167 - 1172