The accuracy of the trifocal IOL calculation using equivalent K-readings and total corneal power in different zones

被引:1
|
作者
Shukhaev, Sergey Viktorovich [1 ]
Pustozerov, Evgenii [2 ]
Boiko, Ernest Vitalievich [1 ]
Kirillova, Olga Valerievna [1 ]
机构
[1] S Fyodorov Eye Microsurg Fed State Inst, Y Gasheka St 21, St Petersburg 192283, Russia
[2] Exposit Consulting Sp Zoo, Jana Heweliusza 11-819, PL-80890 Gdansk, Poland
关键词
Equivalent K-readings; Total keratometry; Keratometry zone; IOL calculation; PREDICTION ACCURACY; KERATOMETRY; OUTCOMES; TOPOGRAPHY;
D O I
10.1007/s00417-023-06198-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo identify the equivalent K-readings and total keratometry zones that is optimally suitable for calculating the IOL spheroequivalent according to 7 formulas.MethodsThe study included 40 patients (40 eyes) who underwent uneventful femtosecond laser-assisted cataract surgery and refractive lens exchange (RLE) with implantation of a trifocal diffractive IOL (PanOptix, Alcon inc.). Targeted emmetropia was achieved in all patients, no distance and near correction was needed. Retrospective IOL calculations were performed utilizing 7 formulas (SRK/T, Holladay 1 and 2, Haigis, Hoffer Q, Barrett Universal 2, Olsen) and Pentacam keratometry data: Holladay equivalent K-readings, total optical power by ray tracing (TCRP) centered on the apex and pupil in 10 zones (from 0.5 to 5 mm in 0.5 mm increments). For each formula/zone/map combination: postoperative predicted refraction (PPRs), mean absolute errors (MAEs), and median absolute errors (MedAEs) were analyzed.ResultsAccording to EKR, the Haigis formula showed the lowest error in the central zones up to 3.5 mm, the TCRP zone for Holladay I and II formulas 4.0-4.5 mm, for HofferQ and SRK/T formulas 4.5-5.0 mm, and for Olsen and Barrett II Universal-5 mm.ConclusionThe use of keratometry data (EKR, TCRP) in the formulas adapted to SimK, with the correct choice of the evaluation zone of keratometric data, will increase the chance of hitting the refractive target.
引用
收藏
页码:495 / 504
页数:10
相关论文
共 36 条
  • [1] The accuracy of the trifocal IOL calculation using equivalent K-readings and total corneal power in different zones
    Sergey Viktorovich Shukhaev
    Evgenii Pustozerov
    Ernest Vitalievich Boiko
    Olga Valerievna Kirillova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 495 - 504
  • [2] Accuracy of IOL power calculation using total keratometry versus regular keratometry
    Reus, N. J.
    ACTA OPHTHALMOLOGICA, 2020, 98 : 31 - 31
  • [3] ACCURACY OF TOTAL CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT TOTAL) COMPARED TO THE TOTAL CORNEAL POWER MEASURED USING 3 DIFFERENT YOMOGRAPHERS
    Alpins, Noel A. M.
    Randleman, Bradley
    Neyvas-Wallce, Anita
    Ong, James
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 51 - 51
  • [4] Accuracy of IOL Power Calculation Using the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL
    Vaiano, Agostino S.
    Hoffer, Kenneth J.
    Greco, Andrea
    Greco, Antonio
    D'Amico, Giovanni
    Pasqualitto, Valerio
    Carlevale, Carlo
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (07) : 472 - 476
  • [5] Comparison of the Accuracy of IOL Power Calculation Formulas for Pediatric Eyes in Children of Different Ages
    Kou, Jiaojiao
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Fu, Yana
    Zhao, Yun-e
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [6] Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK
    Galzignato, Alice
    Galvis, Virgilio
    Tello, Alejandro
    Urrea, Juan F. F.
    Hoffer, Kenneth J. J.
    Coutinho, Catarina P. P.
    Schiano-Lomoriello, Domenico
    Savini, Giacomo
    PHOTONICS, 2023, 10 (06)
  • [7] Refractive Accuracy of Barrett True-K vs Intraoperative Aberrometry for IOL Power Calculation in Post-Corneal Refractive Surgery Eyes
    Gouvea, Larissa
    Sioufi, Kareem
    Brown, Colin E.
    Waring, George
    Chamon, Wallace
    Rocha, Karolinne Maia
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4305 - 4315
  • [8] Differences Between Simulated Keratometry and Total Corneal Power in Eyes With Keratoconus and a Formula to Improve IOL Power Calculation Results
    Coutinho, Catarina P.
    Schiano-Lomoriello, Domenico
    Mazzotta, Cosimo
    Ferrise, Marco
    Hoffer, Kenneth J.
    Ribeiro, Filomena J.
    Dias, Joao Mendanha
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (04) : e253 - e259
  • [9] Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation
    Tamilarasi, S.
    Joseph, Ashalyne James
    Dandapani, Ramamurthy
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) : 582 - 586
  • [10] Prediction accuracy of IOL power calculation in patients with a large difference between conventional keratometry and total keratometry
    Hyon, Joon-Young
    Son, Yengwoo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)