The establishment of national diagnostic reference levels for adult SPECT-CT in Saudi Arabia

被引:3
作者
Al-Qahtani, Saeed Mueed [1 ]
Alidasroos, Moaaz Aqeel [2 ]
Alkhybari, Essam M. [3 ]
Althomali, Marwan Ahmed [1 ]
Alomari, Ali Hamed [4 ]
Bawazeer, Omemh Abdullah [1 ]
Hawsawi, Hassan B. [5 ]
Aamry, Ali Ibrahim [6 ]
Asiri, Jaber Abdulwahab [6 ]
Aloufi, Azzam Abdulaziz [7 ]
Aljehani, Amr Dakhilallah [8 ]
Al-Osaimi, Maram Bandar [9 ]
Alosaimi, Areej Khalid [10 ]
Alsulami, Anwar Khalaf [11 ]
Sabi, Ahmed Yahya [12 ]
Kamli, Talal Mosa [13 ]
Sulieman, Abdelmoneim Adam [3 ]
Ajlouni, Abdul-Wali [1 ]
机构
[1] Umm Al Qura Univ, Coll Appl Sci, Phys Dept, Mecca, Saudi Arabia
[2] Directorate Hlth Affairs, Dept Maintenance, Mecca, Saudi Arabia
[3] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Dept Radiol & Med Imaging, Alkharj, Saudi Arabia
[4] Umm Al Qura Univ, Al Qunfudah Univ Coll, Phys Dept, Mecca, Saudi Arabia
[5] King Abdullah Med City, Adm Med Phys, Mecca, Saudi Arabia
[6] King Saud Med City, Nucl Med Dept, Riyadh, Saudi Arabia
[7] King Abdulaziz Specialist Hosp, Med Phys Dept, Taif, Saudi Arabia
[8] King Fahad Armed Forces Hosp, Med Phys Dept, Jeddah, Saudi Arabia
[9] King Faisal Med Complex, Nucl Med Dept, Taif, Saudi Arabia
[10] King Faisal Med City, Med Phys Dept, Abha, Saudi Arabia
[11] King Fahad Hosp, Nucl Med Dept, Jeddah, Saudi Arabia
[12] King Fahad Cent Hosp, Nucl Med Dept, Jazan, Saudi Arabia
[13] King Fahd Cent Hosp, Nucl Med Dept, Madinah, Saudi Arabia
关键词
national diagnostic reference level; NDRL; nuclear medicine; SPECT-CT; radiation exposure; NUCLEAR-MEDICINE;
D O I
10.1088/1361-6498/ace452
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims to introduce national diagnostic reference levels (NDRLs) for adult hybrid single photon emission computed tomography (SPECT-CT) in nuclear medicine (NM) departments in the Kingdom of Saudi Arabia. The administered activity (AA) of radiopharmaceuticals, volume-weighted computed tomography dose index (CTDIvol) and dose length product (DLP) for ten hybrid SPECT/CT examinations were collected and analysed for one year. The median of AA, CTDIvol and DLP for each dose quantity was derived and the suggested national DRLs were determined based on the 75(th) percentile for all identified SPECT-CT examinations. A comparison of the defined adult NDRLs in Saudi Arabia with the published data of other countries was performed. Although there are no significant variations of the proposed NDRL of AA between countries, the proposed NDRLs of the integrated CT metrics exceed the published data in most procedures. NM departments are urged to consider optimisation for both image quality and radiation protection.
引用
收藏
页数:7
相关论文
共 29 条
[1]   The 2020 national diagnostic reference levels for nuclear medicine in Japan [J].
Abe, Koichiro ;
Hosono, Makoto ;
Igarashi, Takayuki ;
Iimori, Takashi ;
Ishiguro, Masanobu ;
Ito, Teruo ;
Nagahata, Tomomasa ;
Tsushima, Hiroyuki ;
Watanabe, Hiroshi .
ANNALS OF NUCLEAR MEDICINE, 2020, 34 (11) :799-806
[2]  
Administration of Radioactive Substances Advisory Committee, 2023, NOT GUID CLIN ADM RA
[3]   Role of Reference Levels in Nuclear Medicine: A Report of the SNMMI Dose Optimization Task Force [J].
Alessio, Adam M. ;
Farrell, Mary Beth ;
Fahey, Frederic H. .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (12) :1960-1964
[4]   DETERMINING AND UPDATING PET/CT AND SPECT/CT DIAGNOSTIC REFERENCE LEVELS: A SYSTEMATIC REVIEW [J].
Alkhybari, Essam M. ;
McEntee, Mark F. ;
Brennan, Patrick C. ;
Willowson, Kathy P. ;
Hogg, Peter ;
Kench, Peter L. .
RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) :532-545
[5]   National Diagnostic Reference Levels for Nuclear Medicine in Kuwait [J].
Alnaaimi, Meshari A. ;
Alduaij, Mousa A. ;
Shenawy, Faisal A. ;
Algaily, Musab M. ;
Mohammedzein, Talal S. ;
Alkandri, Farida A. ;
Shaban, Mohammed O. ;
Alenezi, Saud A. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2022, 50 (01) :54-59
[6]  
[Anonymous], 2014, REPORT CRITICAL RAW
[7]   A Nordic survey of CT doses in hybrid PET/CT and SPECT/CT examinations [J].
Bebbington, Natalie A. ;
Haddock, Bryan T. ;
Bertilsson, Henrik ;
Hippelainen, Eero ;
Husby, Ellen M. ;
Tunninen, Virpi, I ;
Soderberg, Marcus .
EJNMMI PHYSICS, 2019, 6 (01)
[8]   US PET/CT and Gamma Camera Diagnostic Reference Levels and Achievable Administered Activities for Noncardiac Nuclear Medicine Studies [J].
Becker, Murray D. ;
Butler, Priscilla F. ;
Siam, Mazen ;
Gress, Dustin A. ;
Ghesani, Munir ;
Harkness, Beth A. ;
Yoo, Don C. ;
Oates, M. Elizabeth .
RADIOLOGY, 2019, 293 (01) :203-211
[9]   Adult Gamma Camera Myocardial Perfusion Imaging: Diagnostic Reference Levels and Achievable Administered Activities Derived From ACR Accreditation Data [J].
Becker, Murray D. ;
Butler, Priscilla F. ;
Bhargavan-Chatfield, Mythreyi ;
Harkness, Beth A. ;
Metter, Darlene ;
MacFarlane, Carolyn Richards ;
Ghesani, Munir ;
Wilcox, Pamela ;
Oates, M. Elizabeth .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (06) :688-695
[10]  
Beveridge T., 2019, AUSTR DIAGNOSTIC REF