Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch

被引:2
作者
Rasheed, Nabeel F. [1 ]
Stonebraker, Corinne [1 ]
Li, Zhaozhi [1 ]
Siddiqi, Umar [1 ]
Lee, Andy C. H. [1 ]
Li, Willa [1 ]
Lupo, Sydney [1 ]
Cruz, Jennifer [1 ]
Cohen, William G. [1 ]
Staub, Cathy [1 ]
Rodgers, Daniel [1 ]
Myren, Mark [1 ]
Combs, Pamela [1 ]
Jeevanandam, Valluvan [1 ]
Hibino, Narutoshi [1 ]
机构
[1] Univ Chicago, Dept Surg, Div Cardiothorac Surg, 1109 Ashley Lane, Inverness, IL 60010 USA
关键词
LONG-TERM SURVIVAL; IMPACT; SIZE; REGURGITATION; PERFORMANCE; MORTALITY;
D O I
10.1186/s13019-023-02260-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure- of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM). Methods We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques. Results A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044). Conclusions The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.
引用
收藏
页数:7
相关论文
共 31 条
[1]   Prosthesis size and long-term survival after aortic valve replacement [J].
Blackstone, EH ;
Cosgrove, DM ;
Jamieson, WRE ;
Birkmeyer, NJ ;
Lemmer, JH ;
Miller, DC ;
Butchart, EG ;
Rizzoli, G ;
Yacoub, M ;
Chai, AK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :783-796
[2]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[3]   Safety and Feasibility of a Nonpledgeted Suture Technique for Heart Valve Replacement [J].
Chan, Patrick G. ;
Chan, Ernest G. ;
Seese, Laura ;
Sultan, Ibrahim ;
Kilic, Arman ;
Gleason, Thomas G. ;
Chu, Danny .
JAMA SURGERY, 2019, 154 (03) :260-261
[4]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[5]   Importance of implant technique on risk of major paravatvutar teak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT) [J].
Englberger, L ;
Schaff, HV ;
Jamieson, WRE ;
Kennard, ED ;
Im, KA ;
Holubkov, R ;
Carrel, TP .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (06) :838-843
[6]  
Fernandez J, 1996, CIRCULATION, V94, P109
[7]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[8]   Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch [J].
Kim, Hyo-Hyun ;
Lee, Sak ;
Joo, Hyun-Chel ;
Kim, Jung-Hwan ;
Youn, Young-Nam ;
Yoo, Kyung-Jong ;
Lee, Seung-Hyun .
ANNALS OF THORACIC SURGERY, 2020, 109 (03) :661-667
[9]   Impact of prosthesis - Patient size on functional recovery after aortic valve replacement [J].
Koch, CG ;
Khandwala, F ;
Estafanous, FG ;
Loop, FD ;
Blackstone, EH .
CIRCULATION, 2005, 111 (24) :3221-3229
[10]   Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes [J].
Kodali, Susheel ;
Pibarot, Philippe ;
Douglas, Pamela S. ;
Williams, Mathew ;
Xu, Ke ;
Thourani, Vinod ;
Rihal, Charanjit S. ;
Zajarias, Alan ;
Doshi, Darshan ;
Davidson, Michael ;
Tuzcu, E. Murat ;
Stewart, William ;
Weissman, Neil J. ;
Svensson, Lars ;
Greason, Kevin ;
Maniar, Hersh ;
Mack, Michael ;
Anwaruddin, Saif ;
Leon, Martin B. ;
Hahn, Rebecca T. .
EUROPEAN HEART JOURNAL, 2015, 36 (07) :449-+