Technical Note: Dose voxel resolution determination for Monte Carlo electron beam simulation in thin targets

被引:1
|
作者
Insley, Benjamin Abraham [1 ]
Bartkoski, Dirk Alan [2 ]
Salehpour, Mohammad Reza [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 1420, 1400 Pressler St, Houston, TX 77030 USA
[2] Empyrean Med Syst Inc, Boca Raton, FL USA
关键词
dose modeling; electron beam simulation; error estimation; Geant4; Monte Carlo particle transport;
D O I
10.1002/mp.16344
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMonte Carlo particle simulation has become the primary tool for designing low-energy miniature x-ray tubes due to the difficulties of physically prototyping these devices and characterizing their radiation fields. Accurate simulation of electronic interactions within their targets is necessary for modeling both photon production and heat transfer. Voxel-averaging can conceal hot spots in the target heat deposition profile that can threaten the integrity of the tube. PurposeThis research seeks a computationally-efficient method of estimating voxel-averaging error in energy deposition simulations of electron beams penetrating thin targets to inform the appropriate scoring resolution for a desired accuracy level. MethodsAn analytical model to estimate voxel-averaging along the target depth was developed and compared to results from Geant4 via its wrapper, TOPAS. A 200 keV planar electron beam was simulated to impinge tungsten targets of thicknesses between 1.5- and 12.5-mu m${{\umu {\rm m}}}$. For each target, the model was used to calculate the energy deposition ratio between voxels of varying sizes centered on the longitudinal midpoint of the target. Model-calculated ratios were compared to simulation outputs to gauge the model's accuracy. Then, the model was used to approximate the error between the point value of electron energy deposition and a voxel-based measurement. ResultsThe model underestimates error to within 5% for targets less than 7.5-mu m${{\umu {\rm m}}}$ in thickness with increasing error for greater thicknesses. For the 1.5-mu m${{\umu {\rm m}}}$ target, calculations of the point-vs.-voxel energy deposition show an 11% averaging effect between the midpoint and a 1.5-mu m${{\umu {\rm m}}}$ voxel. Energy deposition profiles along the target depth were also calculated in the Monte Carlo for reference. ConclusionA simple analytical model was developed with reasonable accuracy to guide Monte Carlo users in estimating the appropriate depth-voxel size for thin-target x-ray tube simulations. This methodology can be adapted for other radiological contexts to increase robustness in point-value estimations.
引用
收藏
页码:4637 / 4644
页数:8
相关论文
共 50 条
  • [1] MONTE-CARLO ELECTRON TRAJECTORY SIMULATION OF BEAM SPREADING IN THIN FOIL TARGETS
    NEWBURY, DE
    MYKLEBUST, RL
    ULTRAMICROSCOPY, 1978, 3 (04) : 391 - 395
  • [2] Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets
    Rodriguez, Miguel
    Sempau, Josep
    Brualla, Lorenzo
    MEDICAL PHYSICS, 2015, 42 (06) : 2877 - 2881
  • [3] Dose distribution for electron beam using Monte Carlo simulation with GATE
    Leste, J.
    Chauvin, M.
    Younes, T.
    Vieillevigne, L.
    Bardies, M.
    Franceries, X.
    Ferrand, R.
    Pierrat, N.
    Bartolucci, L.
    Simon, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S967 - S968
  • [4] Automatic determination of primary electron beam parameters in Monte Carlo simulation
    Pena, Javier
    Gonzalez-Castano, Diego M.
    Gomez, Faustino
    Sanchez-Doblado, Francisco
    Hartmann, Guenther H.
    MEDICAL PHYSICS, 2007, 34 (03) : 1076 - 1084
  • [5] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Corp. Res. Proc. Technol. Laboratory, 3M Company, 3M Center, St. Paul, MN 55144-1000, United States
    不详
    不详
    Radiat. Phys. Chem., 5 (475-485):
  • [6] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [7] DETERMINATION OF PRIMARY ELECTRON BEAM PARAMETERS IN MONTE CARLO SIMULATION OF MEDICAL LINAC
    Vaezzadeh, S. A.
    Allahverdi, M.
    Nedaie, H. A.
    Yarahmadi, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S518 - S518
  • [8] Technical Note: A dose calculation framework for dynamic electron arc radiotherapy (DEAR) using VirtuaLinac Monte Carlo simulation tool
    Wang, Xiaorong
    Sawkey, Daren
    Wu, Qiuwen
    MEDICAL PHYSICS, 2020, 47 (01) : 164 - 170
  • [9] Electron beam commissioning for Monte Carlo dose calculation
    Deng, J
    Jiang, SB
    Pawlicki, T
    Li, JS
    Ma, CM
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 431 - 433
  • [10] Monte Carlo simulation of single beam dose profile
    LIU Xiaowei
    WEN Guanghao
    LI Mianfeng(Zhongshan University
    Nuclear Science and Techniques, 1999, (02) : 87 - 90