Deep learning on lateral flow immunoassay for the analysis of detection data

被引:5
作者
Liu, Xinquan [1 ]
Du, Kang [2 ]
Lin, Si [1 ,3 ]
Wang, Yan [1 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin, Peoples R China
[2] Tianjin Boomscience Technol Co Ltd, Tianjin, Peoples R China
[3] Beijing Savant Biotechnol Co Ltd, Beijing, Peoples R China
关键词
lateral flow immunoassay; data processing; point of care testing; deep learning; convolutional neural network; U-Net model; CARE TESTING POCT; PEAK DETECTION; DIAGNOSIS; NETWORK;
D O I
10.3389/fncom.2023.1091180
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Lateral flow immunoassay (LFIA) is an important detection method in vitro diagnosis, which has been widely used in medical industry. It is difficult to analyze all peak shapes through classical methods due to the complexity of LFIA. Classical methods are generally some peak-finding methods, which cannot distinguish the difference between normal peak and interference or noise peak, and it is also difficult for them to find the weak peak. Here, a novel method based on deep learning was proposed, which can effectively solve these problems. The method had two steps. The first was to classify the data by a classification model and screen out double-peaks data, and second was to realize segmentation of the integral regions through an improved U-Net segmentation model. After training, the accuracy of the classification model for validation set was 99.59%, and using combined loss function (WBCE + DSC), intersection over union (IoU) value of segmentation model for validation set was 0.9680. This method was used in a hand-held fluorescence immunochromatography analyzer designed independently by our team. A Ferritin standard curve was created, and the T/C value correlated well with standard concentrations in the range of 0-500 ng/ml (R-2 = 0.9986). The coefficients of variation (CVs) were <= 1.37%. The recovery rate ranged from 96.37 to 105.07%. Interference or noise peaks are the biggest obstacle in the use of hand-held instruments, and often lead to peak-finding errors. Due to the changeable and flexible use environment of hand-held devices, it is not convenient to provide any technical support. This method greatly reduced the failure rate of peak finding, which can reduce the customer's need for instrument technical support. This study provided a new direction for the data-processing of point-of-care testing (POCT) instruments based on LFIA.
引用
收藏
页数:13
相关论文
共 50 条
[31]   Quantitative lateral flow immunoassay for rapid detection of procollagen type I N-terminal propeptide in the monitoring of osteoporosis treatment [J].
Chen, Chung-An ;
Chiu, Ping-Yeh ;
Huang, Tse-Hao ;
Ho, Natalie Yi-Ju ;
Kao, Fu-Cheng ;
Tsai, Tsung-Ting .
ANALYTICA CHIMICA ACTA, 2023, 1239
[32]   Deep learning for anomaly detection in log data: A survey [J].
Landauer, Max ;
Onder, Sebastian ;
Skopik, Florian ;
Wurzenberger, Markus .
MACHINE LEARNING WITH APPLICATIONS, 2023, 12
[33]   Deep learning for anomaly detection in log data: A survey [J].
Landauer, Max ;
Onder, Sebastian ;
Skopik, Florian ;
Wurzenberger, Markus .
MACHINE LEARNING WITH APPLICATIONS, 2023, 12
[34]   Anomaly Detection in Health Data Based on Deep Learning [J].
Han, Ning ;
Gao, Sheng ;
Li, Jin ;
Zhang, Xinming ;
Guo, Jun .
PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON NETWORK INFRASTRUCTURE AND DIGITAL CONTENT (IEEE IC-NIDC), 2018, :188-192
[35]   Redox Cycling Amplified Electrochemical Lateral-Flow Immunoassay: Toward Decentralized Sensitive Insulin Detection [J].
Nandhakumar, Ponnusamy ;
Martin, Cristina Munoz San ;
Arevalo, Beatriz ;
Ding, Shichao ;
Lunker, Mahika ;
Vargas, Eva ;
Djassemi, Omeed ;
Campuzano, Susana ;
Wang, Joseph .
ACS SENSORS, 2023, 8 (10) :3892-3901
[36]   Highly sensitive and selective lateral flow immunoassay based on magnetic nanoparticles for quantitative detection of carcinoembryonic antigen [J].
Liu, Fangming ;
Zhang, Honglian ;
Wu, Zhenhua ;
Dong, Haidao ;
Zhou, Lin ;
Yang, Dawei ;
Ge, Yuqing ;
Jia, Chunping ;
Liu, Huiying ;
Jin, Qinghui ;
Zhao, Jianlong ;
Zhang, Qiqing ;
Mao, Hongju .
TALANTA, 2016, 161 :205-210
[37]   Machine Learning Approach to Enhance the Performance of MNP?Labeled Lateral Flow Immunoassay [J].
Wenqiang Yan ;
Kan Wang ;
Hao Xu ;
Xuyang Huo ;
Qinghui Jin ;
Daxiang Cui .
Nano-Micro Letters, 2019, 11 (01) :132-146
[38]   Detection Method for Abnormal Flow Data in Power Business Based on Deep Learning [J].
Sun, Jinkai ;
Jiao, Guangxu ;
Zhang, Junwei ;
Yao, Junfeng ;
Xiao, Chun .
INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2024, 18 (03) :338-348
[39]   Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries [J].
Pilavaki, Evdokia ;
Demosthenous, Andreas .
SENSORS, 2017, 17 (11)
[40]   Alarm lateral flow immunoassay for detection of the total infection caused by the five viruses [J].
Safenkova, Irina V. ;
Panferov, Vasily G. ;
Panferova, Natalia A. ;
Varitsev, Yuri A. ;
Zherdev, Anatoly V. ;
Dzantiev, Boris B. .
TALANTA, 2019, 195 :739-744