Evaluation of radon concentration measurements in water using the radon degassing method

被引:5
作者
Matsumoto, Maho [1 ]
Yasuoka, Yumi [1 ]
Takakaze, Yui [1 ]
Hosoda, Masahiro [2 ]
Tokonami, Shinji [3 ]
Iwaoka, Kazuki [4 ]
Mukai, Takahiro [5 ]
机构
[1] Kobe Pharmaceut Univ, Radioisotope Res Ctr, Higashinada Ku, 4-19-1 Motoyamakitamachi, Kobe, Hyogo 6588558, Japan
[2] Hirosaki Univ, Dept Radiat Sci, Grad Sch Hlth Sci, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
[3] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Measurement & Phys Dosimetry, 66-1 Hon Cho, Hirosaki, Aomri 0368564, Japan
[4] Natl Inst Quantum Sci & Technol, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[5] Kobe Pharmaceut Univ, Dept Biophys Chem, Higashinada Ku, 4-19-1 Motoyamakitamachi, Kobe, Hyogo 6588558, Japan
关键词
Degassing; Radon; Exposure control; In-situ field measurement;
D O I
10.1007/s10967-022-08698-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study was the first to determine the effectiveness of radon concentration measurement in water using the degassing method as a screening method based on the liquid scintillation counter method. The degassing method used two radon monitors (AlphaGUARD and RAD7) and two monitor-attached degassing devices (AquaKIT and RAD H2O). These were effective screening methods based on the WHO guideline value of 100 Bq L-1. The screening values confirmed that a combination of the AlphaGUARD and AquaKIT was preferred. The results are useful for radon measurement for exposure control in drinking water and environmental in-situ field measurement.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 24 条
[1]  
AARST and ANSI, 2015, PERF SPEC INSTR SYST
[2]  
Baskaran M, 2016, SPRINGER GEOCHEM, P1, DOI 10.1007/978-3-319-21329-3_1
[3]  
Bertin Technologies SAS (Saphymo GmbH), 2009, ALPHAGUARD REF PROF
[4]  
Durridge Company Inc, 2020, RAD H2O RAD WAT ACC
[5]  
EU (European Union), 2013, Off. J. Eur. Union L, V296, P12
[6]  
Haynes W.M., 2013, CRC Handbook of Chemistry and Physics, V93rd, p5
[7]   EVALUATION OF A RADON AIR MONITOR IN THE MEASUREMENT OF RADON CONCENTRATION IN WATER IN COMPARISON WITH A LIQUID SCINTILLATION COUNTER [J].
Higuchi, Shoko ;
Kamishiro, Yuuki ;
Ishihara, Maki ;
Yasuoka, Yumi ;
Mori, Yasunori ;
Hosoda, Masahiro ;
Iwaoka, Kazuki ;
Tokonami, Shinji ;
Takahashi, Rikiya ;
Janik, Miroslaw ;
Muto, Jun ;
Nagahama, Hiroyuki ;
Mukai, Takahiro .
RADIATION PROTECTION DOSIMETRY, 2019, 184 (3-4) :426-429
[8]  
International Organization for Standardization (ISO), 2020, 1316432020 SIST EN I
[9]  
Ishikawa Tetsuo, 2004, Radioisotopes, V53, P133
[10]  
Koike R, 2012, ANN REP NATL VET ASS, V50, P131