Impedance-Readout Integrated Circuits for Electrical Impedance Spectroscopy: Methodological Review

被引:5
|
作者
Cheon, Song-, I [1 ]
Choi, Haidam [1 ]
Kang, Hyoju [2 ]
Suh, Ji-Hoon [1 ]
Park, Seonghyun [1 ]
Kweon, Soon-Jae [2 ]
Je, Minkyu [1 ]
Ha, Sohmyung [3 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Sch Elect Engn, Daejeon 34141, South Korea
[2] Catholic Univ Korea, Sch Informat Commun & Elect Engn, Bucheon 14662, South Korea
[3] New York Univ Abu Dhabi, Div Engn, Abu Dhabi 129188, U Arab Emirates
[4] NYU, Tandon Sch Engn, New York, NY 10003 USA
关键词
Integrated circuits; Impedance; Frequency measurement; Impedance measurement; Throughput; Electrodes; Demodulation; Accuracy; bio-impedance; demodulation; dynamic range; electrode; frequency range; impedance; measurement speed; noise; power consumption; spectroscopy; throughput; BIOIMPEDANCE MEASUREMENT; TOMOGRAPHY SOC; ANALYZER; BODY; CANCELLATION; ELECTRODE; ACCURACY; SENSORS; SYSTEM; CHIP;
D O I
10.1109/TBCAS.2023.3319212
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This review article provides a comprehensive overview of impedance-readout integrated circuits (ICs) for electrical impedance spectroscopy (EIS) applications. The readout IC, a crucial component of on-chip EIS systems, significantly affects key performance metrics of the entire system, such as frequency range, power consumption, accuracy, detection range, and throughput. With the growing demand for portable, wearable, and implantable EIS systems in the Internet-of-Things (IoT) era, achieving high energy efficiency while maintaining a wide frequency range, high accuracy, wide dynamic range, and high throughput has become a focus of research. Furthermore, to enhance the miniaturization and convenience of EIS systems, many emerging systems utilize two-electrode or dry electrode configurations instead of the conventional four-electrode configuration with wet electrodes for impedance measurement. In response to these trends, various technologies have been developed to ensure reliable operations even at two- or dry-electrode interfaces. This article reviews the principles, advantages, and disadvantages of techniques employed in state-of-the-art impedance-readout ICs, aiming to achieve high energy efficiency, wide frequency range, high accuracy, wide dynamic range, low noise, high throughput, and/or high input impedance. The thorough review of these advancements will provide valuable insights into the future development of impedance-readout ICs and systems for IoT and biomedical applications.
引用
收藏
页码:215 / 232
页数:18
相关论文
共 50 条
  • [41] A Low Cost Impedance Measurement Method for Integrated Circuits
    Couraud, Benoit
    Vauche, Remy
    Deleruyelle, Thibaut
    Kussener, Edith
    2015 IEEE 16TH INTERNATIONAL CONFERENCE ON COMMUNICATION TECHNOLOGY (ICCT), 2015, : 13 - 16
  • [43] Impedance spectroscopy for detection of mold in archives with an integrated reference measurement
    Vinayaka, P. Papireddy
    Van den Driesche, S.
    Janssen, S.
    Frodl, M.
    Blank, R.
    Cipriani, F.
    Lang, W.
    Vellekoop, M. J.
    BIO-MEMS AND MEDICAL MICRODEVICES II, 2015, 9518
  • [44] Impedance spectroscopy at semiconductor electrodes: Review and recent developments
    Gomes, WP
    Vanmaekelbergh, D
    ELECTROCHIMICA ACTA, 1996, 41 (7-8) : 967 - 973
  • [45] Linking the Intrinsic Electrical Response of Ferroelectric Devices to Material Properties by Means of Impedance Spectroscopy
    Benatti, Lorenzo
    Vecchi, Sara
    Puglisi, Francesco Maria
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2023, 23 (03) : 309 - 316
  • [46] Identifying Equivalent Circuits of Electrochemical Impedance Spectroscopy Using CNN-LSTM
    Yang, Chang-jiang
    Gao, Bo-bin
    Chang, Jun
    Zhang, Li-hua
    ECS ADVANCES, 2025, 4 (01):
  • [47] Optimization of a Lab on a Chip for Electrical Impedance Spectroscopy Parallel Annulus Test Cell for Electrical Impedance Spectroscopy to minimize uncertainty during measurement
    Ghanshyam, Manjari Jyoti
    Paulson, Kevin
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 763 - 768
  • [48] Assessment of carbon steel microbiologically induced corrosion by electrical impedance spectroscopy
    David A. Miranda
    S. A. Jaimes
    J. M. Bastidas
    Journal of Solid State Electrochemistry, 2014, 18 : 389 - 398
  • [49] Electrical impedance spectroscopy characterisation of conducting membranes I. Theory
    Chilcott, TC
    Chan, M
    Gaedt, L
    Nantawisarakul, T
    Fane, AG
    Coster, HGL
    JOURNAL OF MEMBRANE SCIENCE, 2002, 195 (02) : 153 - 167
  • [50] Kinetics of polymerization of polypyrrole in dielectric matrices probed by electrical impedance spectroscopy
    de Oliveira, HP
    de Melo, CP
    SYNTHETIC METALS, 2006, 156 (2-4) : 215 - 218