Ultra Sensitive Breast Cancer Cell Lines Detection Using Dual Nanocavities Engraved Junctionless FET

被引:10
|
作者
Priyadarshani, Kumari Nibha [1 ]
Singh, Sangeeta [1 ]
机构
[1] Natl Inst Technol Patna, Dept Elect & Commun Engn, Patna 800005, Bihar, India
关键词
Breast cancer; biosensor; junctionless FET; breast cell lines (MCF-10A; Hs578T; MDA-MB-231; MCF-7; and T47D); HIGH-PERFORMANCE; MAMMOGRAPHY; TISSUES; DESIGN; MOSFET; MODEL; RISK; TFET;
D O I
10.1109/TNB.2023.3246106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article reports breast cancer cell lines (Hs578T, MDA-MB-231, MCF-7, and T47D) and healthy breast cells (MCF-10A) detection based on the modulation of its electrical properties by deploying dual nanocavity engraved junctionless FET. The device has a dual gate to enhance gate control and has two nanocavities etched under both gates for breast cancer cell lines immobilization. As the cancer cells are immobilized in the engraved nanocavities, which were earlier filled with air, the dielectric constant of the nanocavities changes. This results in the modulation of the device's electrical parameters. This electrical parameters modulation is then calibrated to detect the breast cancer cell lines. The reported device demonstrates a higher sensitivity toward the detection of breast cancer cells. The JLFET device optimization is done for improving the performance by optimizing the nanocavity thickness and the SiO2 oxide length. The variation in the dielectric property of cell lines plays a key role in the detection technique of the reported biosensor. The sensitivity of the JLFET biosensor is analyzed in terms of Delta VTH, Delta I-ON, Delta g(m), and Delta SS. The reported biosensor shows the maximum sensitivity for T47D (kappa = 32) breast cancer cell line with Delta VTH = 0.800 V, Delta I-ON = 0.165 mA/mu m, Delta g(m) = 0.296 mA/V-mu m, and Delta SS = 5.41 mV/decade. Moreover, the effect of variation in the occupancy of the cavity by the immobilized cell lines has also been studied and analyzed. With increased cavity occupancy the variation in the device performance parameter enhances Further, the sensitivity of the proposed biosensor is compared with the existing biosensors and it is reported to be highly sensitive as compared to the existing biosensors. Hence, the device can be utilized for array based screening of cell lines of breast cancer and diagnosis with the benefit of easier fabrication and cost effectiveness of the device.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [41] Characterization of RNA in exosomes secreted by human breast cancer cell lines using next-generation sequencing
    Jenjaroenpun, Piroon
    Kremenska, Yuliya
    Nair, Vrundha M.
    Kremenskoy, Maksym
    Joseph, Baby
    Kurochkin, Igor V.
    PEERJ, 2013, 1
  • [42] Sialic Acid as a Biomarker Studied in Breast Cancer Cell Lines In Vitro Using Fluorescent Molecularly Imprinted Polymers
    El-Schich, Zahra
    Zhang, Yuecheng
    Goransson, Tommy
    Dizeyi, Nishtman
    Persson, Jenny L.
    Johansson, Emil
    Caraballo, Remi
    Elofsson, Mikael
    Shinde, Sudhirkumar
    Sellergren, Borje
    Wingren, Anette Gjorloff
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [43] Biological purging of breast cancer cell lines using a replication-competent oncolytic virus in human stem cell autografts
    Thirukkumaran, CM
    Luider, JM
    Stewart, DA
    Alain, T
    Russell, JA
    Auer, IA
    Forsyth, P
    Morris, DG
    BONE MARROW TRANSPLANTATION, 2005, 35 (11) : 1055 - 1064
  • [44] Detection of an estrogen derivative in two breast cancer cell lines using a single core multimodal probe for imaging (SCoMPI) imaged by a panel of luminescent and vibrational techniques
    Clede, Sylvain
    Lambert, Francois
    Sandt, Christophe
    Kascakova, Slavka
    Unger, Miriam
    Harte, Etienne
    Plamont, Marie-Aude
    Saint-Fort, Renette
    Deniset-Besseau, Ariane
    Gueroui, Zoher
    Hirschmugl, Carol
    Lecomte, Sophie
    Dazzi, Alexandre
    Vessieres, Anne
    Policar, Clotilde
    ANALYST, 2013, 138 (19) : 5627 - 5638
  • [45] Synergistic inhibition of breast cancer cell lines with a dual inhibitor of EGFR-HER-2/neu and a Bcl-2 inhibitor
    Witters, Lois M.
    Witkoski, Amy
    Planas-Silva, Maricarmen D.
    Berger, Mark
    Viallet, Jean
    Lipton, Allan
    ONCOLOGY REPORTS, 2007, 17 (02) : 465 - 469
  • [46] Novel breast cancer detection system combining both thermoacoustic (TA) and photoacoustic (PA) tomography using carbon nanotubes (CNTs) as a dual contrast agent
    Pramanik, Manojit
    Ku, Geng
    Li, Changhui
    Swierczewska, Magdalena
    Green, Danielle
    Sitharaman, Balaji
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2009, 2009, 7177
  • [47] An amplification strategy using DNA-Peptide dendrimer probe and mass spectrometry for sensitive MicroRNA detection in breast cancer
    Liu, Liang
    Kuang, Yuqiong
    Yang, Hong
    Chen, Yun
    ANALYTICA CHIMICA ACTA, 2019, 1069 : 73 - 81
  • [48] Effect of γ-linolenic acid on cellular uptake of structurally related anthracyclines in human drug sensitive and multidrug resistant bladder and breast cancer cell lines
    Davies, CL
    Loizidou, M
    Cooper, AJ
    Taylor, I
    EUROPEAN JOURNAL OF CANCER, 1999, 35 (10) : 1534 - 1540
  • [49] Dissection of signaling pathways in fourteen breast cancer cell lines using reverse-phase protein lysate microarray
    Akkiprik, Mustafa
    Nicorici, Daniel
    Cogdell, David
    Jia, Yu Jack
    Hategan, Andrea
    Tabus, Ioan
    Yli-Harja, Olli
    Yu, Dihua
    Sahin, Aysegul
    Zhang, Wei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (06) : 543 - 551
  • [50] Breast cancer mitotic cell detection using cascade convolutional neural network with U-Net
    Lu, Xi
    You, Zejun
    Sun, Miaomiao
    Wu, Jing
    Zhang, Zhihong
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2020, 18 (01) : 673 - 695