Ultra Sensitive Breast Cancer Cell Lines Detection Using Dual Nanocavities Engraved Junctionless FET

被引:10
|
作者
Priyadarshani, Kumari Nibha [1 ]
Singh, Sangeeta [1 ]
机构
[1] Natl Inst Technol Patna, Dept Elect & Commun Engn, Patna 800005, Bihar, India
关键词
Breast cancer; biosensor; junctionless FET; breast cell lines (MCF-10A; Hs578T; MDA-MB-231; MCF-7; and T47D); HIGH-PERFORMANCE; MAMMOGRAPHY; TISSUES; DESIGN; MOSFET; MODEL; RISK; TFET;
D O I
10.1109/TNB.2023.3246106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article reports breast cancer cell lines (Hs578T, MDA-MB-231, MCF-7, and T47D) and healthy breast cells (MCF-10A) detection based on the modulation of its electrical properties by deploying dual nanocavity engraved junctionless FET. The device has a dual gate to enhance gate control and has two nanocavities etched under both gates for breast cancer cell lines immobilization. As the cancer cells are immobilized in the engraved nanocavities, which were earlier filled with air, the dielectric constant of the nanocavities changes. This results in the modulation of the device's electrical parameters. This electrical parameters modulation is then calibrated to detect the breast cancer cell lines. The reported device demonstrates a higher sensitivity toward the detection of breast cancer cells. The JLFET device optimization is done for improving the performance by optimizing the nanocavity thickness and the SiO2 oxide length. The variation in the dielectric property of cell lines plays a key role in the detection technique of the reported biosensor. The sensitivity of the JLFET biosensor is analyzed in terms of Delta VTH, Delta I-ON, Delta g(m), and Delta SS. The reported biosensor shows the maximum sensitivity for T47D (kappa = 32) breast cancer cell line with Delta VTH = 0.800 V, Delta I-ON = 0.165 mA/mu m, Delta g(m) = 0.296 mA/V-mu m, and Delta SS = 5.41 mV/decade. Moreover, the effect of variation in the occupancy of the cavity by the immobilized cell lines has also been studied and analyzed. With increased cavity occupancy the variation in the device performance parameter enhances Further, the sensitivity of the proposed biosensor is compared with the existing biosensors and it is reported to be highly sensitive as compared to the existing biosensors. Hence, the device can be utilized for array based screening of cell lines of breast cancer and diagnosis with the benefit of easier fabrication and cost effectiveness of the device.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [21] Comparison of normal and breast cancer cell lines using proteome, genome, and interactome data
    Patwardhan, AJ
    Strittmatter, EF
    Camp, DG
    Smith, RD
    Pallavicini, MG
    JOURNAL OF PROTEOME RESEARCH, 2005, 4 (06) : 1952 - 1960
  • [22] Sensitive Detection of Cell Surface Membrane Proteins in Living Breast Cancer Cells Using Multicolor Fluorescence Microscopy with a Plasmonic Chip
    Tawa, Keiko
    Yamamura, Shohei
    Sasakawa, Chisato
    Shibata, Izumi
    Kataoka, Masatoshi
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (44) : 29893 - 29898
  • [23] Confocal Imaging Using Ultra Wideband Antenna Array on Si Substrates for Breast Cancer Detection
    Kubota, Shinichi
    Xiao, Xia
    Sasaki, Nobuo
    Kayaba, Yasuhisa
    Kimoto, Kentaro
    Moriyama, Wataru
    Kozaki, Takahiro
    Hanada, Maiko
    Kikkawa, Takamaro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (09)
  • [24] Cell-based quantification of biomarkers from an ultra-fast microfluidic immunofluorescent staining: application to breast cancer cell lines
    Migliozzi, D.
    Nguyen, H. T.
    Gijs, M. A. M.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XVI, 2018, 10491
  • [25] Sensitive detection of human breast cancer cells based on aptamer-cell-aptamer sandwich architecture
    Zhu, Xiaoli
    Yang, Jinghua
    Liu, Min
    Wu, Yao
    Shen, Zhongming
    Li, Genxi
    ANALYTICA CHIMICA ACTA, 2013, 764 : 59 - 63
  • [26] Ultra-sensitive and ultra-fast detection of whole unlabeled living cancer cell responses to paclitaxel with a graphene-based biosensor
    Wang, Yijia
    Zhang, Shiwu
    Xu, Ting
    Zhang, Tonglin
    Mo, Yuru
    Liu, Jun
    Yan, Liqun
    Xing, Fei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 263 : 417 - 425
  • [27] Interreader Scoring Variability in an Observer Study Using Dual-Modality Imaging for Breast Cancer Detection in Women with Dense Breasts
    Drukker, Karen
    Horsch, Karla J.
    Pesce, Lorenzo L.
    Giger, Maryellen L.
    ACADEMIC RADIOLOGY, 2013, 20 (07) : 847 - 853
  • [28] Optimized Intelligent Classifier for Early Breast Cancer Detection Using Ultra-Wide Band Transceiver
    Halim, Ahmad Ashraf Abdul
    Andrew, Allan Melvin
    Mustafa, Wan Azani
    Yasin, Mohd Najib Mohd
    Jusoh, Muzammil
    Veeraperumal, Vijayasarveswari
    Abd Rahman, Mohd Amiruddin
    Zamin, Norshuhani
    Mary, Mervin Retnadhas
    Khatun, Sabira
    DIAGNOSTICS, 2022, 12 (11)
  • [29] Co-Encapsulation of Simvastatin and Doxorubicin into pH-Sensitive Liposomes Enhances Antitumoral Activity in Breast Cancer Cell Lines
    Duarte, Jaqueline Aparecida
    Gomes, Eliza Rocha
    De Barros, Andre Luis Branco
    Leite, Elaine Amaral
    PHARMACEUTICS, 2023, 15 (02)
  • [30] MEMS based highly sensitive dual FET gas sensor using graphene decorated Pd-Ag alloy nanoparticles for H2 detection
    Sharma, Bharat
    Kim, Jung-Sik
    SCIENTIFIC REPORTS, 2018, 8