Ultra Sensitive Breast Cancer Cell Lines Detection Using Dual Nanocavities Engraved Junctionless FET

被引:10
|
作者
Priyadarshani, Kumari Nibha [1 ]
Singh, Sangeeta [1 ]
机构
[1] Natl Inst Technol Patna, Dept Elect & Commun Engn, Patna 800005, Bihar, India
关键词
Breast cancer; biosensor; junctionless FET; breast cell lines (MCF-10A; Hs578T; MDA-MB-231; MCF-7; and T47D); HIGH-PERFORMANCE; MAMMOGRAPHY; TISSUES; DESIGN; MOSFET; MODEL; RISK; TFET;
D O I
10.1109/TNB.2023.3246106
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article reports breast cancer cell lines (Hs578T, MDA-MB-231, MCF-7, and T47D) and healthy breast cells (MCF-10A) detection based on the modulation of its electrical properties by deploying dual nanocavity engraved junctionless FET. The device has a dual gate to enhance gate control and has two nanocavities etched under both gates for breast cancer cell lines immobilization. As the cancer cells are immobilized in the engraved nanocavities, which were earlier filled with air, the dielectric constant of the nanocavities changes. This results in the modulation of the device's electrical parameters. This electrical parameters modulation is then calibrated to detect the breast cancer cell lines. The reported device demonstrates a higher sensitivity toward the detection of breast cancer cells. The JLFET device optimization is done for improving the performance by optimizing the nanocavity thickness and the SiO2 oxide length. The variation in the dielectric property of cell lines plays a key role in the detection technique of the reported biosensor. The sensitivity of the JLFET biosensor is analyzed in terms of Delta VTH, Delta I-ON, Delta g(m), and Delta SS. The reported biosensor shows the maximum sensitivity for T47D (kappa = 32) breast cancer cell line with Delta VTH = 0.800 V, Delta I-ON = 0.165 mA/mu m, Delta g(m) = 0.296 mA/V-mu m, and Delta SS = 5.41 mV/decade. Moreover, the effect of variation in the occupancy of the cavity by the immobilized cell lines has also been studied and analyzed. With increased cavity occupancy the variation in the device performance parameter enhances Further, the sensitivity of the proposed biosensor is compared with the existing biosensors and it is reported to be highly sensitive as compared to the existing biosensors. Hence, the device can be utilized for array based screening of cell lines of breast cancer and diagnosis with the benefit of easier fabrication and cost effectiveness of the device.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [11] Modelling the role of dual specificity phosphatases in herceptin resistant breast cancer cell lines
    Buiga, Petronela
    Elson, Ari
    Tabernero, Lydia
    Schwartz, Jean-Marc
    COMPUTATIONAL BIOLOGY AND CHEMISTRY, 2019, 80 : 138 - 146
  • [12] Ultra-sensitive dengue NS1 protein detection via asymmetric source-drain, heterojunction and dual-dielectric cavities in a uniform tunnel FET biosensor
    Kumar, T. Ranjith
    Priya, G. Lakshmi
    RESULTS IN ENGINEERING, 2024, 24
  • [13] Detection of base sequence changes in the CEBPD gene in human breast cancer cell lines and primary breast cancer isolates
    Tang, DH
    DeWille, J
    MOLECULAR AND CELLULAR PROBES, 2003, 17 (01) : 11 - 14
  • [14] The Effects of Eribulin on Breast Cancer Microenvironment Identified Using Eribulin-resistant Breast Cancer Cell Lines
    Goto, Wataru
    Kashiwagi, Shinichiro
    Asano, Yuka
    Takada, Koji
    Takahashi, Katsuyuki
    Fujita, Hisakazu
    Takashima, Tsutomu
    Shibutani, Masatsune
    Amano, Ryosuke
    Tomita, Shuhei
    Hirakawa, Kosei
    Ohira, Masaichi
    ANTICANCER RESEARCH, 2019, 39 (08) : 4031 - 4041
  • [15] Ultra-sensitive detection of hydrogen peroxide and levofloxacin using a dual-functional fluorescent probe
    Shi, Yongqiang
    Wu, Qicong
    Li, Wenting
    Lin, Lei
    Qu, Fangfang
    Shen, Chenjia
    Wei, Yuzhen
    Nie, Pengcheng
    He, Yong
    Feng, Xuping
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 432
  • [16] Ultra Sensitive Label-Free Detection of Biomolecules Using Vertically Extended Drain Double Gate Si0.5Ge0.5 Source Tunnel FET
    Priyadarshani, Kumari Nibha
    Singh, Sangeeta
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2021, 20 (04) : 480 - 487
  • [17] Detection of Oncological Cell for Breast Cancer by using SPR Technology
    Savitha
    Rao, Srinivas
    Sharan, Preeta
    PROCEEDINGS OF THE 10TH INDIACOM - 2016 3RD INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT, 2016, : 2747 - 2749
  • [18] Detection of circulating tumour cells on mRNA levels with established breast cancer cell lines
    Zebisch, Michael
    Koelbl, Alexandra C.
    Andergassen, Ulrich
    Hutter, Stephan
    Neugebauer, Julia
    Engelstzaedter, Verena
    Guenthner-Biller, Maria
    Jeschke, Udo
    Friese, Klaus d
    Rack, Brigitte
    BIOMEDICAL REPORTS, 2013, 1 (02) : 231 - 234
  • [19] Comparative study of Junctionless and Inverted Mode FinFET for detection of breast cancer cell HS578t at microwave frequency
    Sehgal, Himani Dua
    Pratap, Yogesh
    Kabra, Sneha
    2022 IEEE 3RD INTERNATIONAL CONFERENCE ON VLSI SYSTEMS, ARCHITECTURE, TECHNOLOGY AND APPLICATIONS, VLSI SATA, 2022,
  • [20] Gene expression of cytokeratin 19 and its molecular detection in human breast cancer cell lines
    Uawisetwathana, Umaporn
    Rodpai, Ekkarat
    Moongkarndi, Primchanien
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 25 - 31