This article reports breast cancer cell lines (Hs578T, MDA-MB-231, MCF-7, and T47D) and healthy breast cells (MCF-10A) detection based on the modulation of its electrical properties by deploying dual nanocavity engraved junctionless FET. The device has a dual gate to enhance gate control and has two nanocavities etched under both gates for breast cancer cell lines immobilization. As the cancer cells are immobilized in the engraved nanocavities, which were earlier filled with air, the dielectric constant of the nanocavities changes. This results in the modulation of the device's electrical parameters. This electrical parameters modulation is then calibrated to detect the breast cancer cell lines. The reported device demonstrates a higher sensitivity toward the detection of breast cancer cells. The JLFET device optimization is done for improving the performance by optimizing the nanocavity thickness and the SiO2 oxide length. The variation in the dielectric property of cell lines plays a key role in the detection technique of the reported biosensor. The sensitivity of the JLFET biosensor is analyzed in terms of Delta VTH, Delta I-ON, Delta g(m), and Delta SS. The reported biosensor shows the maximum sensitivity for T47D (kappa = 32) breast cancer cell line with Delta VTH = 0.800 V, Delta I-ON = 0.165 mA/mu m, Delta g(m) = 0.296 mA/V-mu m, and Delta SS = 5.41 mV/decade. Moreover, the effect of variation in the occupancy of the cavity by the immobilized cell lines has also been studied and analyzed. With increased cavity occupancy the variation in the device performance parameter enhances Further, the sensitivity of the proposed biosensor is compared with the existing biosensors and it is reported to be highly sensitive as compared to the existing biosensors. Hence, the device can be utilized for array based screening of cell lines of breast cancer and diagnosis with the benefit of easier fabrication and cost effectiveness of the device.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [1] Breast Cancer Detection Using Dual Nanocavities GaN Junctionless FinFET Biosensor
    Gupta, Shweta
    Pratap, Yogesh
    Gupta, Mridula
    SENSING AND IMAGING, 2025, 26 (01):
  • [2] Performance assessment of dielectrically modulated negative capacitance germanium source vertical tunnel FET biosensor for detection of breast cancer cell lines
    Vanlalawmpuia, K.
    Ghosh, Puja
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2023, 171
  • [3] Label-free detection of breast cancer cell lines using dopingless heterojunction TFET considering non-ideal hybridization issue
    Dewan, Basudha
    Chaudhary, Shalini
    Singh, Devenderpal
    Yadav, Menka
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2024, 302
  • [4] Extrachromosomal DNA in Breast Cancer Cell Lines: Detection and Characterization
    Irdianto, Shadira Anindieta
    Fadhillah, Fadhillah
    Lestari, Retno
    Fadilah, Fadilah
    Bowolaksono, Anom
    Dwiranti, Astari
    MICROSCOPY RESEARCH AND TECHNIQUE, 2024, : 1239 - 1247
  • [5] Highly Stable InSe-FET Biosensor for Ultra-Sensitive Detection of Breast Cancer Biomarker CA125
    Ji, Hao
    Wang, Zhenhua
    Wang, Shun
    Wang, Chao
    Zhang, Kai
    Zhang, Yu
    Han, Lin
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [6] Dual aptamer-functionalized silica nanoparticles for the highly sensitive detection of breast cancer
    Jo, Hunho
    Her, Jin
    Ban, Changill
    BIOSENSORS & BIOELECTRONICS, 2015, 71 : 129 - 136
  • [7] MicroRNA expression profiling of endocrine sensitive and resistant breast cancer cell lines
    Khajah, Maitham A.
    Al-Ateyah, Alyaa
    Luqmani, Yunus A.
    BIOCHEMISTRY AND BIOPHYSICS REPORTS, 2022, 31
  • [8] Dielectric Characterization of Breast Cancer Cell Lines Using Microwaves
    Jithin, Dwija
    Hussein, M. I.
    Awwad, Falah
    Irtini, Rabah
    2016 5TH INTERNATIONAL CONFERENCE ON ELECTRONIC DEVICES, SYSTEMS AND APPLICATIONS (ICEDSA), 2016,
  • [9] Non-invasive ultra-sensitive detection of breast cancer biomarker using cerium nanoparticle functionalized graphene oxide enabled impedimetric aptasensor
    Parihar, Arpana
    Vishwakarma, Preeti
    Prajapati, Pradeep
    Khan, Raju
    BIOSENSORS & BIOELECTRONICS, 2025, 268
  • [10] Effect of quercetin on doxorubicin cytotoxicity in sensitive and resistant human MCF7 breast cancer cell lines
    Aljabr, Bayan Almohammad
    Zihlif, Malek
    Abu-Dahab, Rana
    Zalloum, Hiba
    BIOMEDICAL REPORTS, 2024, 20 (04)