Automated and subjective refraction with monofocal, multifocal, and EDOF intraocular lenses: review

被引:13
作者
Bellucci, Carlo [1 ]
Mora, Paolo [1 ]
Tedesco, Salvatore Antonio [1 ]
Gandolfi, Stefano [1 ]
Bellucci, Roberto [2 ]
机构
[1] Univ Hosp Parma, Ophthalmol Unit, Parma, Italy
[2] Vista Vis Clin, Verona, Italy
关键词
EXTENDED DEPTH; AUTOREFRACTION; REPEATABILITY; AGREEMENT; IMPLANTATION; PERFORMANCE; ABERROMETRY; EXPERIENCE; VALIDITY; VISION;
D O I
10.1097/j.jcrs.0000000000001186
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Automated refraction (Scheiner principle) is universally used to start a visual examination. Although the results are reliable in eyes implanted with monofocal intraocular lenses (IOLs), they may be less precise with multifocal (mIOL) or extended depth-of- focus (EDOF) IOLs and can even indicate a refractive error that does not clinically exist. Autorefractor results with monofocal, multifocal, and EDOF IOLs were investigated through literature search analyzing the papers reporting the difference between automated and clinical refraction. The average difference ranged between -0.50 diopter (D) and -1.00 D with most mIOL and EDOF IOLs. The differences in astigmatism were generally much lower. Autorefractors using infrared light cannot measure eyes with high technology IOLs precisely because of the influence of the refractive or of the diffractive near add. The systematic error induced with some IOLs should be mentioned in the IOL label to prevent possible inappropriate refractive procedures to treat apparent myopia. Copyright (c) 2023 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:642 / 648
页数:7
相关论文
共 50 条
[1]  
Akil Handan, 2015, Korean J Ophthalmol, V29, P178, DOI 10.3341/kjo.2015.29.3.178
[2]   Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Koopman, Bram ;
Weeber, Henk ;
Auffarth, Gerd U. ;
Piers, Patricia A. .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) :520-+
[3]   Validity of automated refraction after segmented refractive multifocal intraocular lens implantation [J].
Albarran-Diego, Cesar ;
Munoz, Gonzalo ;
Rohrweck, Stephanie ;
Garcia-Lazaro, Santiago ;
Ricardo Albero, Jose .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (11) :1728-1733
[4]   PSEUDOACCOMMODATION WITH THE 3M DIFFRACTIVE MULTIFOCAL INTRAOCULAR-LENS - A REFRACTION STUDY OF 52 SUBJECTS [J].
BELLUCCI, R ;
GIARDINI, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01) :32-35
[5]   Clinical and aberrometric evaluation of a new extended depth-of-focus intraocular lens based on spherical aberration [J].
Bellucci, Roberto ;
Cargnoni, Miriam ;
Bellucci, Carlo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (07) :919-926
[6]   A New Extended Depth of Focus Intraocular Lens Based on Spherical Aberration [J].
Bellucci, Roberto ;
Curatolo, Maria C. .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (06) :389-+
[7]  
Bennett Jeffrey R, 2015, J Optom, V8, P109, DOI 10.1016/j.optom.2014.11.001
[8]   Autorefraction after implantation of diffractive multifocal intraocular lenses [J].
Bissen-Miyajima, Hiroko ;
Minami, Keiichiro ;
Yoshino, Mami ;
Nishimura, Mariko ;
Oki, Shinchi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :553-556
[9]   Impact of Decentration and Tilt on Spherical, Aberration Correcting, and Specific Aspherical Intraocular Lenses: An Optical Bench Analysis [J].
Borkenstein, Andreas F. ;
Borkenstein, Eva-Maria ;
Luedtke, Holger ;
Schmid, Ruediger .
OPHTHALMIC RESEARCH, 2022, 65 (04) :425-436
[10]   The repeatability of automated and clinician refraction [J].
Bullimore, MA ;
Fusaro, RE ;
Adams, CW .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (08) :617-622