Off-Axis Loading Fixture for Spine Biomechanics: Combined Compression and Bending

被引:2
作者
Moore, Axel C. [1 ]
Holder, Dione A. [2 ]
Elliott, Dawn M. [2 ]
机构
[1] Univ Delaware, Dept Biomed Engn, STAR Hlth Sci Complex, Room 109 540 S Coll Ave, Newark, DE 19713 USA
[2] Univ Delaware, Dept Biomed Engn, Newark, DE 19713 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2023年 / 145卷 / 10期
关键词
biomechanics; multi-axis mechanics; functional spinal unit; spine biomechanics; intervertebral disc; MOTION SEGMENT STIFFNESS; LUMBAR SPINE; INTERVERTEBRAL DISC; INTRADISCAL PRESSURE; ROTATION; FREEDOM; DEGENERATION; FLEXIBILITY;
D O I
10.1115/1.4062780
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The spine is a multi-tissue musculoskeletal system that supports large multi-axial loads and motions during physiological activities. The healthy and pathological biomechanical function of the spine and its subtissues are generally studied using cadaveric specimens that often require multi-axis biomechanical test systems to mimic the complex loading environment of the spine. Unfortunately, an off-the-shelf device can easily exceed 200,000 USD, while a custom device requires extensive time and experience in mechatronics. Our goal was to develop a cost-appropriate compression and bending (flexion-extension and lateral bending) spine testing system that requires little time and minimal technical knowledge. Our solution was an off-axis loading fixture (OLaF) that mounts to an existing uni-axial test frame and requires no additional actuators. OLaF requires little machining, with most components purchased off-the-shelf, and costs less than 10,000 USD. The only external transducer required is a six-axis load cell. Furthermore, OLaF is controlled using the existing uni-axial test frame's software, while the load data is collected using the software included with the six-axis load cell. Here we provide the design rationale for how OLaF develops primary motions and loads and minimizes off-axis secondary constraints, verify the primary kinematics using motion capture, and demonstrate that the system is capable of applying physiologically relevant, noninjurious, axial compression and bending. While OLaF is limited to compression and bending studies it produces repeatable physiologically relevant biomechanics, with high quality data, and minimal startup costs.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] Fracture patterns of the adolescent porcine spine:: An experimental loading study in bending-compression
    Baranto, A
    Ekström, L
    Hellström, M
    Lundin, O
    Holm, S
    Swärd, L
    SPINE, 2005, 30 (01) : 75 - 82
  • [2] Failure tolerance of the human lumbar spine in dynamic combined compression and flexion loading
    Tushak, Sophia K.
    Donlon, John Paul
    Gepner, Bronislaw D.
    Chebbi, Aida
    Pipkorn, Bengt
    Hallman, Jason J.
    Forman, Jason L.
    Kerrigan, Jason R.
    JOURNAL OF BIOMECHANICS, 2022, 135
  • [3] Influence of off-axis loading of an anterior maxillary implant: A 3-dimensional finite element analysis
    Hsu, Ming-Lun
    Chen, Fang-Ching
    Kao, Hung-Chan
    Cheng, Cheng-Kung
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (02) : 301 - 309
  • [4] Expanded Combined Loading Injury Criterion for the Human Lumbar Spine Under Dynamic Compression
    Ortiz-Paparoni, Maria
    Op 't Eynde, Joost
    Eckersley, Christopher
    Morino, Concetta
    Abrams, Mitchell
    Pang, Derek
    Kait, Jason
    Pintar, Frank
    Yoganandan, Narayan
    Moore, Jason
    Barnes, David
    Loftis, Kathryn
    Bass, Cameron R.
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (11) : 3067 - 3077
  • [5] In the Rodent Tail Loading Model, Locations of Cancellous Tissue with High Mechanical Strain are not Affected by Small Off-axis Loads
    Goff, M. G.
    Chang, K. L.
    Litts, E. N.
    Hernandez, C. J.
    2013 39TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC 2013), 2013, : 92 - 93
  • [6] Strain energy density distribution of vertebral body of two motion segment model under combined compression and sagittal bending moment - An in vitro porcine spine biomechanical study
    Wang, JL
    Tsai, YC
    Yang, BD
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2004, 27 (06) : 927 - 934