Influence of off-grid/grid-connected operation on stability of large-scale photovoltaic system

被引:3
|
作者
Fu, Yu [1 ]
Li, Wei [1 ]
Xiong, Nan [1 ]
Fang, Yang [1 ]
He, Xiaomeng [1 ]
Wang, Zufeng [1 ]
机构
[1] Guizhou Power Grid Co Ltd, Elect Power Res Inst, Guiyang 550002, Guizhou, Peoples R China
关键词
Photovoltaic penetration; Transmission line length; Renewables; Stability; ENERGY; GENERATION; SUPPORT;
D O I
10.1016/j.egyr.2023.04.234
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Off-grid or grid-connected operation of large-scale photovoltaic system may cause stability problems. When the system performs off-grid operation, energy storage, as balance node, regulates power and frequency, then also influences stability. Under grid-connected operation, the external power system balances power and frequency regulation, and energy storage only equilibrium wave power. Although a detailed model for a single photovoltaic generation system has been established, the connection of numerous photovoltaic units is difficult to model and simulate, and it can easily cause dimension disaster. In order to analyze stability effectively of off-grid/grid-connected operation of large-scale photovoltaic system, we first establish the equivalent model of a photovoltaic farm through the method of dynamic aggregation of wind turbines, and then obtain indicators affecting the stability considering the reactance matrix of the transmission line. When the real part of the oscillation mode sensitivity index is greater than zero, oscillation mode approaches the imaginary axis, indicating that the PV system stability deteriorates. Conversely, the PV system is regionally stable. Finally, the effects of the number of photovoltaic units and transmission line length on stability are theoretically analyzed, and the theoretical derivation is validated through simulations. More PV units and a longer transmission line increase the likelihood of instability through the sensitivity of the oscillation mode. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:904 / 910
页数:7
相关论文
共 50 条
  • [31] Performance analysis of a grid-connected photovoltaic park after 6 years of operation
    Roumpakias, Elias
    Stamatelos, Anastassios
    RENEWABLE ENERGY, 2019, 141 : 368 - 378
  • [32] Stability and performance analysis of a single-stage grid-connected photovoltaic system using describing function theory
    Hejri, Mohammad
    Mokhtari, Hossein
    Karimi, Soraya
    Azizian, Mohammadreza
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (09): : 1898 - 1916
  • [33] Design and operation optimization of city-level off-grid hydro-photovoltaic complementary system
    Zhang, Bo
    Qiu, Rui
    Liao, Qi
    Liang, Yongtu
    Ji, Haoran
    Jing, Rui
    APPLIED ENERGY, 2022, 306
  • [34] Full-order models and dynamic assessment of droop-controlled grid-connected and off-grid DC microgrids
    Silveira, Rafaela D.
    da Silva, Sergio A. O.
    Sampaio, Leonardo P.
    Machado, Sebastian de Jesus Manrique
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 64
  • [35] Separated Frequency Stability Analysis of Grid-connected PV System Affected by Weak Grid
    Liu J.
    Yu M.
    Xia Y.
    Wei W.
    Dianwang Jishu/Power System Technology, 2020, 44 (01): : 86 - 95
  • [36] Stability Analysis of Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Cheng, Lin
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1514 - 1518
  • [37] Sizing a grid-connected photovoltaic system under economic and environmental uncertainties
    Attia, Ahmed M.
    Darghouth, Mohamed N.
    Ghaithan, Ahmed M.
    Mohammed, Awsan
    SOLAR ENERGY, 2023, 265
  • [38] Improvement of the integration of a grid-connected wind-photovoltaic hybrid system
    Abbassi, Rabeh
    Hammami, Manel
    Chebbi, Souad
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND SOFTWARE APPLICATIONS (ICEESA), 2013, : 1 - 5
  • [39] Fault Diagnosis in a Grid-Connected Photovoltaic System by Applying a Signal Approach
    Gonzalez, Mario
    Raison, Bertrand
    Bacha, Seddik
    Bun, Long
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 1354 - 1359
  • [40] An improved model and performance analysis for grid-connected photovoltaic system in Oman
    Al-Shahri, Omar A.
    Ismail, Firas B.
    Al-Muhsen, Nizar F. O.
    Al-Bazi, Ammar
    Hannan, M. A.
    HELIYON, 2022, 8 (12)