Influence of dental implant/mini-implant design on stress distribution in overdentures: a systematic review

被引:1
作者
Rigotti, Renan Leonardi de Oliveira [1 ]
Tardelli, Juliana Dias Corpa [1 ]
Dos Reis, Andrea Candido [1 ]
da Valente, Mariana Lima Costa [1 ]
机构
[1] Univ Sao Paulo, Ribeirao Preto Dent Sch, Dept Dent Mat & Prosthodont, Ave Do Cafe S-N, BR-14040904 Ribeirao Preto, SP, Brazil
来源
ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG | 2024年 / 28卷 / 02期
基金
英国科研创新办公室;
关键词
Overdenture; Dental implants; Stress distribution; Finite element method;
D O I
10.1007/s10006-023-01177-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeCritically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?".MethodsThis systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters.ResultsSixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction).ConclusionIt can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.
引用
收藏
页码:515 / 527
页数:13
相关论文
共 50 条
  • [21] Investigation of the dental implant geometry effect on stress distribution at dental implant-bone interface
    Ghadiri, Majid
    Shafiei, Navvab
    Salekdeh, Sadegh Hemmati
    Mottaghi, Parya
    Mirzaie, Tahereh
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (02) : 335 - 343
  • [22] Systematic Review of Prosthetic Maintenance Requirements for Implant-Supported Overdentures
    Cehreli, Murat Cavit
    Karasoy, Durdu
    Kokat, Ali Murat
    Akca, Kivanc
    Eckert, Steven E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (01) : 163 - 180
  • [23] Comparative Study of the Influence of Dental Implant Design on the Stress and Strain Distribution using the Finite Element Method
    Sahai, Neha Srivastava
    Yadav, Divya
    Madhav, Srishti
    Kumar, Naveen
    Dubey, Anuradha
    Qadeer, Nazia
    Makkad, Ramanpal Singh
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2776 - S2778
  • [24] Biomechanical Aspects of Various Attachments for Implant Overdentures: A Review
    Mirchandani, Bharat
    Zhou, Ting
    Heboyan, Artak
    Yodmongkol, Sirasa
    Buranawat, Borvornwut
    POLYMERS, 2021, 13 (19)
  • [25] Influence of cortical bone quality on stress distribution in bone around dental implant
    Kitagawa, T
    Tanimoto, Y
    Nemoto, K
    Aida, M
    DENTAL MATERIALS JOURNAL, 2005, 24 (02) : 219 - 224
  • [26] Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study
    Soganci, Gokce
    Yazicioglu, Huseyin
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2016, 53 (01) : 73 - 83
  • [27] The Biomechanical Impact of Loss of an Implant in the Treatment with Mandibular Overdentures on Four Nonsplinted Mini Dental Implants: A Finite Element Analysis
    Teodorescu, Cristian
    Preoteasa, Elena
    Preoteasa, Cristina Teodora
    Murariu-Magureanu, Catalina
    Teodorescu, Ioana Monica
    MATERIALS, 2022, 15 (23)
  • [28] The Effect of Offset Implant Configuration on Bone Stress Distribution: A Systematic Review
    de Souza Batista, Victor Eduardo
    Santiago Junior, Joel Ferreira
    de Faria Almeida, Daniel Augusto
    de Toledo Piza Lopes, Leonardo Ferreira
    Verri, Fellippo Ramos
    Pellizzer, Eduardo Piza
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02): : 93 - 99
  • [29] Peri-implant mucosal response to implant-supported overdentures: A systematic review and meta-analysis
    Baskaradoss, Jagan Kumar
    Geevarghese, Amrita
    Baig, Mirza Rustum
    GERODONTOLOGY, 2021, 38 (01) : 27 - 40
  • [30] PATIENTS' SATISFACTION WITH CONVENTIONAL DENTURES AND MINI IMPLANT ANCHORED OVERDENTURES
    Preoteasa, Elena
    Marin, Mihaela
    Imre, Marina
    Lerner, Henriette
    Preoteasa, Cristina Teodora
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2012, 116 (01): : 310 - 316