Magnetic chitosan-zeolite composite as an adsorbent in ultrasound-assisted magnetic solid phase extraction of tetracyclines in water samples

被引:15
|
作者
Lefatle, Mpho Charmaine [1 ,2 ]
Madikizela, Lawrence Mzukisi [3 ]
Pakade, Vusumzi Emmanuel [4 ]
Nomngongo, Philiswa Nosizo [1 ,2 ]
机构
[1] Univ Johannesburg, Dept Chem Sci, Doornfontein Campus, POB 17011, ZA-2028 Doornfontein, South Africa
[2] Univ Johannesburg, Natl Res Fdn South Afr Res Chair Initiat DSI NRF, Dept Sci & Innovat, ZA-2028 Doornfontein, South Africa
[3] Univ South Africa, Inst Nanotechnol & Water Sustainabil, Coll Sci Engn & Technol, ZA-1710 Roodepoort, South Africa
[4] Univ South Africa, Coll Sci, Dept Chem Engn & Technol, Florida Sci Campus, ZA-1710 Roodepoort, South Africa
基金
新加坡国家研究基金会;
关键词
Tetracyclines; Response surface methodology; Wastewater; Ultrasound-assisted magnetic solid phase extraction; Environmental monitoring; WASTE-WATER; FE3O4; NANOPARTICLES; SURFACE-WATER; ANTIBIOTICS; REMOVAL; RESIDUES; ADSORPTION; SORBENT; OXIDE;
D O I
10.1186/s40543-023-00394-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasound-assisted magnetic solid-phase extraction method was developed to pre-concentrate tetracyclines (TCs) in wastewater and river water. The magnetic chitosan-zeolite composite was used as an adsorbent. The morphological and structural properties of the adsorbent were characterised by various analytical techniques. The factors affecting the ultrasound-assisted magnetic solid-phase extraction method were optimised using a central composite design. A high performance liquid chromatography equipped with a photodiode array detector was used to quantify TCs in wastewater and river water samples. Under optimised parameters, the developed analytical approach gave acceptable linearity (LOQ-400 & mu;g L-1) with correlation coefficients exceeding 0.993, while the detection and quantitation limits ranged from 0.05-0.67 and 0.14-2.03 & mu;g L-1, respectively. Attained recoveries were 90-101%, with intraday and interday precision expressed as the relative standard deviation (%RSD) below 5%. Even though the target analytes (tetracycline, oxytetracycline and oxytetracycline) were not detected in environmental samples, the synthesised adsorbent was suitable for the isolation of TCs in a complex matrix resulting in an accurate, precise, rapid and sensitive analytical method.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Synthesis of a novel magnetic zeolite-hydroxyapatite adsorbent via microwave-assisted method for protein adsorption via magnetic solid-phase extraction
    Piri, Farhad
    Mollahosseini, Afsaneh
    Khadir, Ali
    Milani Hosseini, Mohamadreza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (07) : 1635 - 1648
  • [32] Carbon coated magnetic nanoparticles as a novel magnetic solid phase extraction adsorbent for simultaneous extraction of methamphetamine and ephedrine from urine samples
    Taghvimi, Arezou
    Hamishehkar, Hamed
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1041 : 113 - 119
  • [33] Ultrasound-assisted dispersive magnetic solid-phase extraction of cadmium, lead and copper ions from water and fruit juice samples using DABCO-based poly (ionic liquid) functionalized magnetic nanoparticles
    Sahebi, Hamed
    Fard, Sayyed Massoud Bahrololoomi
    Rahimi, Farnaz
    Jannat, Behrooz
    Sadeghi, Nafiseh
    FOOD CHEMISTRY, 2022, 396
  • [34] Ultrasound-assisted dispersive magnetic solid-phase extraction of cadmium, lead and copper ions from water and fruit juice samples using DABCO-based poly (ionic liquid) functionalized magnetic nanoparticles
    Sahebi, Hamed
    Massoud Bahrololoomi Fard, Sayyed
    Rahimi, Farnaz
    Jannat, Behrooz
    Sadeghi, Nafiseh
    Food Chemistry, 2022, 396
  • [35] Ultrasound-assisted extraction methods for the determination of organic contaminants in solid and liquid samples
    Perez, Rosa A.
    Albero, Beatriz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 166
  • [36] A uniform magnetic field assisted automated magnetic micro solid-phase extraction for the determination of trace molinate in water and rice samples
    Mohammadipour, Leila
    Jafari, Mohammad T.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [37] Preparation and characterization of magnetic carboxylated nanodiamonds for vortex-assisted magnetic solid-phase extraction of ziram in food and water samples
    Yilmaz, Erkan
    Soylak, Mustafa
    TALANTA, 2016, 158 : 152 - 158
  • [38] S-quinolin-2-yl-methyldithiocarbazate-based magnetic adsorbent for magnetic solid-phase extraction of heavy metals from water samples
    Rahman, Ahmad Jazmi Abdul
    Fiona, How N. -F
    Nasir, Mohd Hamzah Mohd
    Mohamad, Sharifah
    Yahaya, Noorfatimah
    Jajuli, Maizatul Najwa
    Miskam, Mazidatulakmam
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 101 (14) : 2069 - 2086
  • [39] Ultrasound-Assisted Extraction of Magnetic Material From Natural Iron Sand
    Istiningrum, Reni Banowati
    Pamungkas, Febria Lutfi Udin
    Santosa, Sri Juari
    Nuryono
    INTERNATIONAL CONFERENCE ON SCIENCE AND APPLIED SCIENCE (ICSAS2020), 2020, 2296
  • [40] Evaluation of ultrasound-assisted in situ sorbent formation solid-phase extraction method for determination of arsenic in water, food and biological samples
    Ezoddin, Maryam
    Majidi, Behrooz
    Abdi, Khosrou
    ENVIRONMENTAL TECHNOLOGY, 2015, 36 (11) : 1381 - 1388