Magnetic chitosan-zeolite composite as an adsorbent in ultrasound-assisted magnetic solid phase extraction of tetracyclines in water samples

被引:15
作者
Lefatle, Mpho Charmaine [1 ,2 ]
Madikizela, Lawrence Mzukisi [3 ]
Pakade, Vusumzi Emmanuel [4 ]
Nomngongo, Philiswa Nosizo [1 ,2 ]
机构
[1] Univ Johannesburg, Dept Chem Sci, Doornfontein Campus, POB 17011, ZA-2028 Doornfontein, South Africa
[2] Univ Johannesburg, Natl Res Fdn South Afr Res Chair Initiat DSI NRF, Dept Sci & Innovat, ZA-2028 Doornfontein, South Africa
[3] Univ South Africa, Inst Nanotechnol & Water Sustainabil, Coll Sci Engn & Technol, ZA-1710 Roodepoort, South Africa
[4] Univ South Africa, Coll Sci, Dept Chem Engn & Technol, Florida Sci Campus, ZA-1710 Roodepoort, South Africa
基金
新加坡国家研究基金会;
关键词
Tetracyclines; Response surface methodology; Wastewater; Ultrasound-assisted magnetic solid phase extraction; Environmental monitoring; WASTE-WATER; FE3O4; NANOPARTICLES; SURFACE-WATER; ANTIBIOTICS; REMOVAL; RESIDUES; ADSORPTION; SORBENT; OXIDE;
D O I
10.1186/s40543-023-00394-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasound-assisted magnetic solid-phase extraction method was developed to pre-concentrate tetracyclines (TCs) in wastewater and river water. The magnetic chitosan-zeolite composite was used as an adsorbent. The morphological and structural properties of the adsorbent were characterised by various analytical techniques. The factors affecting the ultrasound-assisted magnetic solid-phase extraction method were optimised using a central composite design. A high performance liquid chromatography equipped with a photodiode array detector was used to quantify TCs in wastewater and river water samples. Under optimised parameters, the developed analytical approach gave acceptable linearity (LOQ-400 & mu;g L-1) with correlation coefficients exceeding 0.993, while the detection and quantitation limits ranged from 0.05-0.67 and 0.14-2.03 & mu;g L-1, respectively. Attained recoveries were 90-101%, with intraday and interday precision expressed as the relative standard deviation (%RSD) below 5%. Even though the target analytes (tetracycline, oxytetracycline and oxytetracycline) were not detected in environmental samples, the synthesised adsorbent was suitable for the isolation of TCs in a complex matrix resulting in an accurate, precise, rapid and sensitive analytical method.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Magnetic chitosan-zeolite composite as an adsorbent in ultrasound-assisted magnetic solid phase extraction of tetracyclines in water samples
    Mpho Charmaine Lefatle
    Lawrence Mzukisi Madikizela
    Vusumzi Emmanuel Pakade
    Philiswa Nosizo Nomngongo
    Journal of Analytical Science and Technology, 14
  • [2] Magnetic solid-phase extraction of tetracyclines using ferrous oxide coated magnetic silica microspheres from water samples
    Lian, Lili
    Lv, Jinyi
    Wang, Xiyue
    Lou, Dawei
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1534 : 1 - 9
  • [3] Magnetic hybrid support for ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from produced water
    Lima de Barros Gaetano, Vinicius Crispim
    Cunha, Graziele da Costa
    Matos Oliveira, Rhayza Victoria
    Alexandre, Marcelo da Rosa
    Cruz Romao, Luciane Pimenta
    MICROCHEMICAL JOURNAL, 2019, 146 : 1195 - 1203
  • [4] Dispersive magnetic solid phase extraction using octadecyl coated silica magnetite nanoparticles for the extraction of tetracyclines in water samples
    Kaewsuwan, Watchara
    Kanatharana, Proespichaya
    Bunkoed, Opas
    JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (09) : 957 - 965
  • [5] Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis
    Ibarra, Israel S.
    Rodriguez, Jose A.
    Miranda, Jose M.
    Vega, Marisol
    Barrado, Enrique
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (16) : 2196 - 2202
  • [6] Magnetic coffee residue as sorbent for magnetic solid-phase extraction and determination of titanium dioxide nanoparticles in water samples
    Firomesa, Hundera
    Amde, Meseret
    Bekana, Deribachew
    Temesgen, Ayalew
    CHEMICAL PAPERS, 2022, 76 (04) : 2267 - 2277
  • [7] Ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons from water samples with a magnetic polyaniline modified graphene oxide nanocomposite
    Manousi, N.
    Deliyanni, E. A.
    Rosenberg, E.
    Zachariadis, G. A.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1645
  • [8] Ultrasound-assisted magnetic solid phase extraction of lead and thallium in complex environmental samples using magnetic multi-walled carbon nanotubes/zeolite nanocomposite
    Gugushe, Aphiwe Siyasanga
    Mpupa, Anele
    Nomngongo, Philiswa N.
    MICROCHEMICAL JOURNAL, 2019, 149
  • [9] Ultrasound-assisted mixed hemimicelle magnetic solid phase extraction followed by high performance liquid chromatography for the quantification of atorvastatin in biological and aquatic samples
    Khoshhesab, Zahra Monsef
    Ayazi, Zahra
    Farrokhrouz, Zahra
    ANALYTICAL METHODS, 2016, 8 (24) : 4934 - 4940
  • [10] Ultrasound-assisted magnetic solid-phase extraction for the determination of some transition metals in Orujo spirit samples by capillary electrophoresis
    Pena Crecente, Rosa M.
    Gutierrez Lovera, Carlha
    Barciela Garcia, Julia
    Herrero Latorre, Carlos
    Garcia Martin, Sagrario
    FOOD CHEMISTRY, 2016, 190 : 263 - 269