Predictive Value of Eosinophil Cationic Protein in Nasal Secretions in Eosinophilic Chronic Rhinosinusitis

被引:4
|
作者
Jin, Jing [1 ,2 ]
Guo, Bei [3 ]
Zhang, Wei [1 ,2 ]
Chen, Jian-jun [4 ]
Deng, Yu-qing [1 ,2 ]
Xiang, Rong [2 ]
Tan, Lu [1 ,2 ]
Liu, Pei-qiang [1 ,2 ]
Zheng, Li [1 ,2 ]
Chen, Zhe [5 ]
Tao, Ze-zhang [1 ,2 ]
Xu, Yu [1 ,2 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Otolaryngol Head & Neck Surg, 238 Jiefang Rd, Wuhan 430060, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Res Inst Otolaryngol Head & Neck Surg, Wuhan, Peoples R China
[3] Cent Hosp Wuhan, Dept Otolaryngol, Wuhan, Peoples R China
[4] Tongji Med Coll, Union Hosp, Dept Otolaryngol Head & Neck Surg, Wuhan, Peoples R China
[5] Wuhan Univ, Zhongnan Hosp, Dept Otolaryngol Head & Neck Surg, Wuhan 430060, Peoples R China
基金
中国国家自然科学基金;
关键词
eosinophil; eosinophil cationic protein; eosinophilic chronic rhinosinusitis with nasal polyps; nasal secretions; receiver operating characteristic curves; ALLERGIC RHINITIS; INFLAMMATORY MEDIATORS; MAST-CELLS; MUCOSA; POLYPOSIS; ENDOTYPES; PATTERNS; MARKERS; DISEASE; SERUM;
D O I
10.1002/lary.30692
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: To investigate the value of secretions Eosinophilic cationic protein (ECP) detection in the diagnosis of endotypes of Chronic rhinosinusitis (CRS) and its correlation with clinical symptoms, so as to provide guidance for the clinical application of EOS and ECP detection in secretions. Methods: Patients' nasal secretions and polyps (or middle turbinate for control) were collected and their EOS% and ECP levels were measured. Correlation analysis was performed for EOS% and ECP levels in secretions and tissues, respectively. The correlation between secretions EOS% and ECP and clinical symptom scores (symptomatic visual analog scale (VAS) scores, Lanza-kennedy scores from nasal endoscopy and Lund-Mackay scores from sinus CT) was further analyzed. Receiver operating characteristic curves were used to assess the predictive potential of EOS% and ECP in nasal secretions. Results: Eosinophilic chronic rhinosinusitis (ECRS) patients had higher concentrations of ECP in nasal secretions than healthy subjects and NECRS (non-eosinophilic CRS) (p < 0.0001;0.0001); EOS% in nasal secretions was higher in ECRS than healthy subjects (p = 0.0055), but the differences between ECRS and NECRS were not statistically significant (p = 0.0999). Correlation analysis showed that tissue EOS% was correlated with ECP concentration and EOS% in nasal secretions (R = 0.5943;0.2815). There was a correlation between EOS% in secretions with a total LM score (R = 0.3131); ECP concentration in secretions with a total LK score (R = 0.3792). To diagnose ECRS, the highest area under the curve (0.8230) was determined for ECP in secretions; the highest area under the curve (0.6635) was determined for EOS% in secretions. Conclusion: Measurement of ECP in nasal secretions is useful for non-invasive diagnosis of ECRS.
引用
收藏
页码:3304 / 3312
页数:9
相关论文
共 50 条
  • [21] The effect of short-term immunotherapy with molecular standardized grass and rye allergens on eosinophil cationic protein and tryptase in nasal secretions
    Klimek, L
    Wolf, H
    Mewes, T
    Dormann, D
    Reske-Kunz, A
    Schnitker, J
    Mann, W
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : 47 - 53
  • [22] Immunoglobulins in nasal secretions of patients with allergic rhinitis and chronic rhinosinusitis
    Chung-Han Hsin
    Chia-Tung Shun
    Chia-Ming Liu
    European Archives of Oto-Rhino-Laryngology, 2008, 265 : 539 - 542
  • [23] Dysregulated Maresin Concentrations in Plasma and Nasal Secretions From Patients With Chronic Rhinosinusitis
    Beegun, Issa
    Koenis, Duco S.
    Alusi, Ghassan
    Dalli, Jesmond
    FRONTIERS IN IMMUNOLOGY, 2021, 12
  • [24] Cell activation markers in Rhintis and Rhinosinusitis .1. Eosinophil cationic protein
    Klimek, L
    Rasp, G
    LARYNGO-RHINO-OTOLOGIE, 1996, 75 (11) : 665 - 670
  • [25] Subclassification of Chronic Rhinosinusitis With Nasal Polyp Based on Eosinophil and Neutrophil
    Ikeda, Katsuhisa
    Shiozawa, Akihito
    Ono, Noritsugu
    Kusunoki, Takeshi
    Hirotsu, Mikio
    Homma, Hirotomo
    Saitoh, Tatsuya
    Murata, Junko
    LARYNGOSCOPE, 2013, 123 (11) : E1 - E9
  • [26] Diagnostic Value of a Novel Eosinophil Cationic Protein-Myeloperoxidase Test Paper Before and After Treatment for Allergic Rhinitis
    Xi, Yang
    Deng, Yu-Qin
    Li, Han-Da
    Jiao, Wo-Er
    Chen, Jin
    Chen, Jian-Jun
    Tao, Ze-Zhang
    JOURNAL OF ASTHMA AND ALLERGY, 2022, 15 : 1005 - 1019
  • [27] Eosinophil Peroxidase: A Biomarker for Eosinophilic Chronic Rhinosinusitis Agnostic of Polyp Status
    Idler, Beau M.
    Iijima, Koji
    Ochkur, Sergei I.
    Jacobsen, Elizabeth A.
    Rank, Matthew A.
    Kita, Hirohito
    Lal, Devyani
    LARYNGOSCOPE, 2024, 134 (01) : 69 - 78
  • [28] Investigation of the Value of T2 Mapping in the Prediction of Eosinophilic Chronic Rhinosinusitis With Nasal Polyps
    Wang, Yuchen
    Lou, Hongfei
    Xian, Mu
    Cui, Jing
    Piao, Yingshi
    Wang, Chengshuo
    Zhang, Luo
    Xian, Junfang
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (02) : 329 - 336
  • [29] Macrophage Inflammatory Protein-1 Production and Eosinophil Infiltration in Chronic Rhinosinusitis With Nasal Polyps
    Peric, Aleksandar
    Baletic, Nenad
    Sotirovic, Jelena
    Spadijer-Mirkovic, Cveta
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2015, 124 (04) : 266 - 272
  • [30] Determinants of eosinophil cationic protein in nasal lavages in children
    Wojnarowski, C
    Studnicka, M
    Kühr, J
    Koller, DY
    Haschke, N
    Gartner, C
    Renz, S
    Frischer, T
    CLINICAL AND EXPERIMENTAL ALLERGY, 1998, 28 (03) : 300 - 305