Failure modes and effects analysis study for accelerator-based Boron Neutron Capture Therapy

被引:4
|
作者
Takemori, Mihiro [1 ,2 ,3 ]
Nakamura, Satoshi [1 ,3 ,4 ,9 ]
Sofue, Toshimitsu [5 ]
Ito, Mikiko [6 ]
Goka, Tomonori [5 ]
Miura, Yuki [7 ]
Iijima, Kotaro [1 ]
Chiba, Takahito [1 ,2 ]
Nakayama, Hiroki [1 ,2 ]
Nakaichi, Tetsu [1 ]
Mikasa, Shohei [1 ]
Takano, Yuki [1 ]
Kon, Mitsuhiro [1 ,5 ]
Shuto, Yasunori [1 ,5 ]
Urago, Yuka [1 ,2 ]
Nishitani, Masato [1 ,2 ]
Kashihara, Tairo [8 ]
Takahashi, Kana [8 ]
Murakami, Naoya [8 ]
Nishio, Teiji
Okamoto, Hiroyuki [1 ]
Chang, Weishan [2 ]
Igaki, Hiroshi [3 ,8 ]
机构
[1] Natl Canc Ctr, Div Radiat Safety & Qual Assurance, Chuo Ku, Tokyo, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Human Hlth Sci, Dept Radiol Sci, Arakawa Ku, Tokyo, Japan
[3] Natl Canc Ctr, Div Boron Neutron Capture Therapy, Exploratory Oncol Res & Clin Trial Ctr, Chuo Ku, Tokyo, Japan
[4] Osaka Univ, Grad Sch Med, Div Hlth Sci, Med Phys Lab, Suita, Osaka, Japan
[5] Natl Canc Ctr, Dept Radiol Technol, Chuo Ku, Tokyo, Japan
[6] Natl Canc Ctr, Dept Nursing, Chuo Ku, Tokyo, Japan
[7] Natl Canc Ctr Hosp East, Dept Radiol Technol, Kashiwa, Chiba, Japan
[8] Natl Canc Ctr, Dept Radiat Oncol, Chuo Ku, Tokyo, Japan
[9] 5-1-1 Tsukiji, Chuo Ku, Tokyo 1040045, Japan
关键词
boron neutron capture therapy (BNCT); failure mode and effects analysis (FMEA); specific FM; RADIATION-THERAPY; RECURRENT; HEAD;
D O I
10.1002/mp.16104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundBoron Neutron Capture Therapy (BNCT) has recently been used in clinical oncology thanks to recent developments of accelerator-based BNCT systems. Although there are some specific processes for BNCT, they have not yet been discussed in detail. PurposeThe aim of this study is to provide comprehensive data on the risk of accelerator-based BNCT system to institutions planning to implement an accelerator-based BNCT system. MethodsIn this study, failure mode and effects analysis (FMEA) was performed based on a treatment process map prepared for the accelerator-based BNCT system. A multidisciplinary team consisting of a medical doctor (MD), a registered nurse (RN), two medical physicists (MP), and three radiologic technologists (RT) identified the failure modes (FMs). Occurrence (O), severity (S), and detectability (D) were scored on a scale of 10, respectively. For each failure mode (FM), risk priority number (RPN) was calculated by multiplying the values of O, S, and D, and it was then categorized as high risk, very high risk, and other. Additionally, FMs were statistically compared in terms of countermeasures, associated occupations, and whether or not they were the patient-derived. ResultsThe identified FMs for BNCT were 165 in which 30 and 17 FMs were classified as high risk and very high risk, respectively. Additionally, 71 FMs were accelerator-based BNCT-specific FMs in which 18 and 5 FMs were classified as high risk and very high risk, respectively. The FMs for which countermeasures were "Education" or "Confirmation" were statistically significantly higher for S than the others (p = 0.019). As the number of BNCT facilities is expected to increase, staff education is even more important. Comparing patient-derived and other FMs, O tended to be higher in patient-derived FMs. This could be because the non-patient-derived FMs included events that could be controlled by software, whereas the patient-derived FMs were impossible to prevent and might also depend on the patient's condition. Alternatively, there were non-patient-derived FMs with higher D, which were difficult to detect mechanically and were classified as more than high risk. In O, significantly higher values (p = 0.096) were found for FMs from MD and RN associated with much patient intervention compared to FMs from MP and RT less patient intervention. Comparing conventional radiotherapy and accelerator-based BNCT, although there were events with comparable risk in same FMs, there were also events with different risk in same FMs. They could be related to differences in the physical characteristics of the two modalities. ConclusionsThis study is the first report for conducting a risk analysis for BNCT using FMEA. Thus, this study provides comprehensive data needed for quality assurance/quality control (QA/QC) in the treatment process for facilities considering the implementation of accelerator-based BNCT in the future. Because many BNCT-specific risks were discussed, it is important to understand the characteristics of BNCT and to take adequate measures in advance. If the effects of all FMs and countermeasures are discussed by multidisciplinary team, it will be possible to take countermeasures against individual FMs from many perspectives and provide BNCT more safely and effectively.
引用
收藏
页码:424 / 439
页数:16
相关论文
共 50 条
  • [21] A study on out-of-field leakage of an accelerator-based neutron beam for boron neutron capture therapy
    You, Zhen-Fan
    Huang, Chun-Kai
    Liu, Yen-Wan Hsueh
    FRONTIERS IN ONCOLOGY, 2024, 13
  • [22] Accelerator-based boron neutron capture therapy facility at the Helsinki University Hospital
    Porra, Liisa
    Seppala, Tiina
    Wendland, Lauri
    Revitzer, Hannu
    Joensuu, Heikki
    Eide, Paul
    Koivunoro, Hanna
    Smick, Noah
    Smick, Theodore
    Tenhunen, Mikko
    ACTA ONCOLOGICA, 2022, 61 (02) : 269 - 273
  • [23] Evaluation of moderator assemblies for use in an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1998, 123 (03) : 320 - 334
  • [24] Study of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapy
    Verdera, Antonia
    Torres-Sanchez, Pablo
    Praena, Javier
    Porras, Ignacio
    APPLIED RADIATION AND ISOTOPES, 2024, 212
  • [25] CONCEPTUAL DESIGN OF AN RFQ ACCELERATOR-BASED NEUTRON SOURCE FOR BORON NEUTRON-CAPTURE THERAPY
    WANGLER, TP
    STOVALL, JE
    BHATIA, TS
    WANG, CK
    BLUE, TE
    GAHBAUER, RA
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 678 - 680
  • [26] Design of an accelerator-based neutron source for neutron capture therapy
    Terlizzi, R.
    Colonna, N.
    Colangelo, P.
    Maiorana, A.
    Marrone, S.
    Raino, A.
    Tagliente, G.
    Variale, V.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S292 - S295
  • [27] Strategies for Preclinical Studies Evaluating the Biological Effects of an Accelerator-Based Boron Neutron Capture Therapy System
    Kondo, Natsuko
    Masutani, Mitsuko
    Imamichi, Shoji
    Matsumoto, Yoshitaka
    Nakai, Kei
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2023, 38 (03) : 173 - 183
  • [28] Implications of radiation microdosimetry for accelerator-based boron neutron capture therapy: a radiobiological perspective
    Fukunaga, Hisanori
    Matsuya, Yusuke
    Tokuuye, Koichi
    Omura, Motoko
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1111):
  • [29] Experimental verification of in-phantom calculations for an accelerator-based neutron source for boron neutron capture therapy
    Dobelbower, MC
    Vest, A
    Reed, MJ
    Blue, TE
    MEDICAL PHYSICS, 1999, 26 (03) : 376 - 380
  • [30] Development and application of neutron field optimization parameters for an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1996, 115 (01) : 100 - 113