Establishment of an institutional diagnostic reference level for vascular lower extremity computed tomography angiography

被引:2
|
作者
Sulieman, Abdelmoneim [1 ]
Alkhorayef, Mohammed [2 ]
Alkhaybari, Essam [3 ]
Jaafar, Rasha [4 ]
Elnour, Abdelrahman [5 ]
Almujally, Abdullah [6 ]
Babikir, Esameldeen [7 ]
Abuzaid, Mohamed [8 ]
Abuhadi, Nouf [9 ]
Salah, Hassan [10 ]
Bradley, David A. [11 ]
机构
[1] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Appl Med Sci, Radiol Sci Dept, POB 2477, Al Hasa 31982, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[3] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[4] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Basic Sci Dept, Khartoum, Sudan
[5] Natl Ribat Univ, Coll Radiol & Nucl Med, Khartoum, Sudan
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[7] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, POB 32038, Manama, Bahrain
[8] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah, U Arab Emirates
[9] Jazan Univ, Coll Appl Med Sci, Diagnost Radiog Technol Dept, Jazan, Saudi Arabia
[10] Inaya Med Coll, Dept Nucl Med Technol, POB 271 880, Riyadh 11352, Saudi Arabia
[11] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
CT angiography; Radiation risk; Diagnostic imaging; CT; ABDOMEN; CHEST; ACCURACY; EXPOSURE; ORGAN; SUDAN; RISK;
D O I
10.1016/j.radphyschem.2023.111460
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
About 70% of all collective doses from medical tests come from computed tomography (CT), the primary public radiation exposure source. Patients received higher doses during contrast-enhanced CT procedures (Angiography) than routine CT procedures. The current research aims to quantify the patients' radiation doses, estimate the cancer risk probability, and establish institutional diagnostic reference level (IDRL) during lower extremity angiography. One hundred eleven patients (61.3% male and 38.7% female) underwent contrast-enhanced CT procedures. A 160-Slice CT scanner was used for image acquisition for all patient populations. IDRL values were quantified based on the 3rd quartile value of the CT dose descriptors. All procedures were carried out at AlMoaallim Medical City, Khartoum, Sudan. A computer software (CT-Expo, ImPACT) was used to extrapolate the effective dosage per extremity CTA examination was estimated. The mean patient age (years) was 56.1 +/- 18 (18-82). The patient's radiation doses was quantified using volume CTDI and dose length product (DLP) to 7.3 +/- 2 (2.9-16.8) (mGy) and 3712 +/- 126 (279-8374) (mGy.cm), respectively. The average effective doses were 22 mSv (range: 1.7-50) per lower CT angiography for the lower extremity. The proposed IDRL for the VCTA procedure was 3562 mGy cm and 17 mGy for DLP and CTDIvol, respectively. The proposed IDRL is higher than the previously published studies; therefore, patient dose optimization is recommended.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] CT Angiography of Lower Extremity Vascular Bypass Grafts
    Toomay, Seth M.
    Dolmatch, Bart L.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 9 (04) : 172 - 179
  • [32] Establishment of multi-slice computed tomography (MSCT) reference level in Johor, Malaysia
    Karim, M. K. A.
    Hashim, S.
    Bakar, K. A.
    Muhammad, H.
    Sabarudin, A.
    Ang, W. C.
    Bahruddin, N. A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [33] Computed tomography scanning in the diagnosis of lower extremity phlebolymphedema
    Thaggard, David
    Powell, Thomas
    Jayaraj, Arjun
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2025, 13 (03)
  • [34] Computed tomography angiography is associated with low added utility for detecting clinically relevant vascular injuries among patients with extremity trauma
    Brian, Riley
    Bennett, Daniel J.
    Kim, Woon Cho
    Stein, Deborah M.
    TRAUMA SURGERY & ACUTE CARE OPEN, 2021, 6 (01)
  • [35] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Najafi, Mohsen
    Deevband, Mohammad Reza
    Ahmadi, Mohsen
    Kardan, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 603 - 609
  • [36] Establishment of Diagnostic Reference Levels and Evaluation of Radiation Dose in Double Phase Abdominopelvic Computed Tomography
    Keshtkar M.
    Iranian Journal of Medical Physics, 2023, 20 (02) : 80 - 86
  • [37] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [38] Diagnostic reference levels for common pediatric computed tomography studies: A retrospective study.
    Khafaji, Mawya
    Barnawi, Rashid
    Amoudi, Salma
    Gabbani, Hassan
    Alhazmi, Rayan
    Ahyad, Rayan
    Alsafi, Khalid
    Saeedi, Khuld
    Salah, Hassan
    Tamam, Nissren
    Bradley, David
    Albahiti, Sarah
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [39] Incidence and clinical impact of lower extremity vascular injuries in the setting of whole body computed tomography for trauma
    Weger, Kendal
    Hammer, Peter
    McKinley, Todd
    Steenburg, Scott
    EMERGENCY RADIOLOGY, 2021, 28 (02) : 265 - 272
  • [40] Effective radiation dose of three diagnostic tests in cardiology: Single photon emission computed tomography, invasive coronary angiography and cardiac computed tomography angiography
    Goncalves, Pedro de Araujo
    Sousa, Pedro Jeronimo
    Cale, Rita
    Marques, Hugo
    dos Santos, Miguel Borges
    Dias, Andre
    Dores, Helder
    Carvalho, Maria Salome
    Ventosa, Antonio
    Martins, Teresa
    Teles, Rui Campante
    Almeida, Manuel
    Mendes, Miguel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (12) : 981 - 986