Establishment of an institutional diagnostic reference level for vascular lower extremity computed tomography angiography

被引:2
|
作者
Sulieman, Abdelmoneim [1 ]
Alkhorayef, Mohammed [2 ]
Alkhaybari, Essam [3 ]
Jaafar, Rasha [4 ]
Elnour, Abdelrahman [5 ]
Almujally, Abdullah [6 ]
Babikir, Esameldeen [7 ]
Abuzaid, Mohamed [8 ]
Abuhadi, Nouf [9 ]
Salah, Hassan [10 ]
Bradley, David A. [11 ]
机构
[1] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Appl Med Sci, Radiol Sci Dept, POB 2477, Al Hasa 31982, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[3] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[4] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Basic Sci Dept, Khartoum, Sudan
[5] Natl Ribat Univ, Coll Radiol & Nucl Med, Khartoum, Sudan
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[7] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, POB 32038, Manama, Bahrain
[8] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah, U Arab Emirates
[9] Jazan Univ, Coll Appl Med Sci, Diagnost Radiog Technol Dept, Jazan, Saudi Arabia
[10] Inaya Med Coll, Dept Nucl Med Technol, POB 271 880, Riyadh 11352, Saudi Arabia
[11] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
CT angiography; Radiation risk; Diagnostic imaging; CT; ABDOMEN; CHEST; ACCURACY; EXPOSURE; ORGAN; SUDAN; RISK;
D O I
10.1016/j.radphyschem.2023.111460
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
About 70% of all collective doses from medical tests come from computed tomography (CT), the primary public radiation exposure source. Patients received higher doses during contrast-enhanced CT procedures (Angiography) than routine CT procedures. The current research aims to quantify the patients' radiation doses, estimate the cancer risk probability, and establish institutional diagnostic reference level (IDRL) during lower extremity angiography. One hundred eleven patients (61.3% male and 38.7% female) underwent contrast-enhanced CT procedures. A 160-Slice CT scanner was used for image acquisition for all patient populations. IDRL values were quantified based on the 3rd quartile value of the CT dose descriptors. All procedures were carried out at AlMoaallim Medical City, Khartoum, Sudan. A computer software (CT-Expo, ImPACT) was used to extrapolate the effective dosage per extremity CTA examination was estimated. The mean patient age (years) was 56.1 +/- 18 (18-82). The patient's radiation doses was quantified using volume CTDI and dose length product (DLP) to 7.3 +/- 2 (2.9-16.8) (mGy) and 3712 +/- 126 (279-8374) (mGy.cm), respectively. The average effective doses were 22 mSv (range: 1.7-50) per lower CT angiography for the lower extremity. The proposed IDRL for the VCTA procedure was 3562 mGy cm and 17 mGy for DLP and CTDIvol, respectively. The proposed IDRL is higher than the previously published studies; therefore, patient dose optimization is recommended.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Quality of referrals for lower extremity ultrasonography and computed tomography pulmonary angiography and associations with positive findings of venous thromboembolism
    Naimi, S.
    Odegaard, K. J.
    Jenssen, K. K.
    Lauritzen, P. M.
    RADIOGRAPHY, 2024, 30 (03) : 799 - 805
  • [22] Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 983 - 991
  • [23] Comparison of the 64-and 80-detector row computed tomography among the CT number and radiation dose during lower extremity computed tomography angiography
    Moriwake, Ryo
    Masuda, Takanori
    Yamamoto, Akira
    Ikenaga, Hiroyuki
    Yoshida, Koji
    Takei, Yasutaka
    Yao, Daiki
    Ono, Atsushi
    Hiratsuka, Junichi
    Tamada, Tsutomu
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (04) : 356 - 362
  • [24] Prospective Evaluation of Multidetector Computed Tomography for Extremity Vascular Trauma
    Inaba, Kenji
    Branco, Bernardino C.
    Reddy, Sravanthi
    Park, John J.
    Green, Donald
    Plurad, David
    Talving, Peep
    Lam, Lydia
    Demetriades, Demetrios
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04): : 808 - 814
  • [25] National diagnostic reference level initiative for computed tomography examinations in Kenya
    Korir, Geoffrey K.
    Wambani, Jeska S.
    Korir, Ian K.
    Tries, Mark A.
    Boen, Patrick K.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (02) : 242 - 252
  • [26] Diagnostic and Prognostic Value of Coronary Computed Tomography Angiography in Patients with Severe Calcification
    Diaz-Anton, Belen
    Solis, Jorge
    Diaz Morales, Roberto
    Lopez-Melgar, Beatriz
    Barrio, Patricia
    Moreno, Andrea
    Unzue, Leire
    Alvarez-Vieitez, Antonio
    Medina, Juan
    Garcia, Eulogio
    Parra Jimenez, Francisco Javier
    Fernandez-Friera, Leticia
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2021, 14 (01) : 131 - 139
  • [27] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [28] ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
    Zamani, Hamed
    Masjedi, Hamidreza
    Omidi, Reza
    Hosein Zare, Mohammad
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 222 - 231
  • [30] Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland
    Deleu, Marine
    Dagassan, Dorothea
    Berg, Isabelle
    Bize, Julie
    Dula, Karl
    Lenoir, Vincent
    Ott, Barbara
    Ott, Julien G.
    Verdun, Francis R.
    Weber, Robert
    Ziglinas, Panagiotis
    Zingariello, Cesare
    Merce, Marta Sans
    DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)