Establishment of an institutional diagnostic reference level for vascular lower extremity computed tomography angiography

被引:2
|
作者
Sulieman, Abdelmoneim [1 ]
Alkhorayef, Mohammed [2 ]
Alkhaybari, Essam [3 ]
Jaafar, Rasha [4 ]
Elnour, Abdelrahman [5 ]
Almujally, Abdullah [6 ]
Babikir, Esameldeen [7 ]
Abuzaid, Mohamed [8 ]
Abuhadi, Nouf [9 ]
Salah, Hassan [10 ]
Bradley, David A. [11 ]
机构
[1] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Appl Med Sci, Radiol Sci Dept, POB 2477, Al Hasa 31982, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 10219, Riyadh 11433, Saudi Arabia
[3] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Alkharj 11942, Saudi Arabia
[4] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Basic Sci Dept, Khartoum, Sudan
[5] Natl Ribat Univ, Coll Radiol & Nucl Med, Khartoum, Sudan
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[7] Univ Bahrain, Coll Hlth & Sport Sci, Radiol Technol Program, POB 32038, Manama, Bahrain
[8] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah, U Arab Emirates
[9] Jazan Univ, Coll Appl Med Sci, Diagnost Radiog Technol Dept, Jazan, Saudi Arabia
[10] Inaya Med Coll, Dept Nucl Med Technol, POB 271 880, Riyadh 11352, Saudi Arabia
[11] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
CT angiography; Radiation risk; Diagnostic imaging; CT; ABDOMEN; CHEST; ACCURACY; EXPOSURE; ORGAN; SUDAN; RISK;
D O I
10.1016/j.radphyschem.2023.111460
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
About 70% of all collective doses from medical tests come from computed tomography (CT), the primary public radiation exposure source. Patients received higher doses during contrast-enhanced CT procedures (Angiography) than routine CT procedures. The current research aims to quantify the patients' radiation doses, estimate the cancer risk probability, and establish institutional diagnostic reference level (IDRL) during lower extremity angiography. One hundred eleven patients (61.3% male and 38.7% female) underwent contrast-enhanced CT procedures. A 160-Slice CT scanner was used for image acquisition for all patient populations. IDRL values were quantified based on the 3rd quartile value of the CT dose descriptors. All procedures were carried out at AlMoaallim Medical City, Khartoum, Sudan. A computer software (CT-Expo, ImPACT) was used to extrapolate the effective dosage per extremity CTA examination was estimated. The mean patient age (years) was 56.1 +/- 18 (18-82). The patient's radiation doses was quantified using volume CTDI and dose length product (DLP) to 7.3 +/- 2 (2.9-16.8) (mGy) and 3712 +/- 126 (279-8374) (mGy.cm), respectively. The average effective doses were 22 mSv (range: 1.7-50) per lower CT angiography for the lower extremity. The proposed IDRL for the VCTA procedure was 3562 mGy cm and 17 mGy for DLP and CTDIvol, respectively. The proposed IDRL is higher than the previously published studies; therefore, patient dose optimization is recommended.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Establishment of institutional diagnostic reference level for Computed Tomography dose on 160 slicer Computed Tomography scan at Lady Reading Hospital Peshawar
    Khan, Muhammad Imran
    Khan, Muhammad Zeeshan
    Afzal, Fariha
    Zenab
    Khan, Shandana
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 808 - 811
  • [2] Computed Tomographic Angiography as the Primary Diagnostic Modality in Penetrating Lower Extremity Vascular Injuries: A Level I Trauma Experience
    Wallin, Dina
    Yaghoubian, Arezou
    Rosing, David
    Walot, Irving
    Chauvapun, Joe
    de Virgilio, Christian
    ANNALS OF VASCULAR SURGERY, 2011, 25 (05) : 620 - 623
  • [3] Establishment of diagnostic reference levels in cardiac computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    Zaitoun, Maha
    Abdelrahman, Mostafa
    Brennan, Patrick
    Alewaidat, Haytham
    McEntee, Mark F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 181 - 186
  • [4] Establishment of institutional Diagnostic Reference Levels for Computed Tomography examination at the University of Ghana Medical Centre
    Issahaku, Shirazu
    Amoh, Simon Mensah
    Acquah, Isaac Kwesi
    Nunoo, George
    Sackey, Theophilus A.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1199 - 1207
  • [5] Establishment of diagnostic reference level for computed tomography of head pediatrics in Morocco: A pilot study
    Semghouli, Slimane
    Aabid, Mohammed
    Amaoui, Bouchra
    Choukri, Abdelmajid
    El Kharras, Abdennasser
    MATERIALS TODAY-PROCEEDINGS, 2022, 52 : 85 - 88
  • [6] Radiogenic risk assessment for abdominal vascular computed tomography angiography
    Sulieman, Abdelmoneim
    Adam, Hussein
    Mahmoud, M. Z.
    Hamid, O.
    Alkhorayef, Mohammed
    Bradley, David A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [7] Diagnostic reference levels for routine computed tomography angiography examinations: a systematic review
    Alhailiy, Ali Bahny
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [8] The development of a diagnostic reference level on patient dose for head computed tomography angiography examinations in Korea
    Cho, Pyong-Kon
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) : 505 - 509
  • [9] Diagnostic reference level for computed tomography abdominal examinations: A multicentre study
    Sulieman, A.
    Elnour, A.
    Mahmoud, M. Z.
    Alkhorayef, M.
    Hamid, O.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 174
  • [10] Abdomen and pelvis computed tomography procedure: Effective dose assessment and establishment of a local diagnostic reference level
    Almujally, Abdullah
    Alenezi, Saad
    Aldosary, Khalid Nasser
    Otayni, Ahmed
    Sulieman, Abdelmoneim
    Abdelghani, Amr
    Tamam, Nissren
    Mohtasib, Rafat
    Masawi, Ahmed
    Moftah, Belal
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 203