Identification of broken conductor faults in interconnected transmission systems based on discrete wavelet transform

被引:1
|
作者
Rashad, Basem Abd-Elhamed [1 ]
Ibrahim, Doaa K. [2 ]
Gilany, Mahmoud I. [2 ]
Abdelhamid, Ahmed Sayed [1 ]
Abdelfattah, Wael [1 ]
机构
[1] El Shorouk Acad, Higher Inst Engn El Shorouk City, Dept Elect Power & Machines Engn, Cairo, Egypt
[2] Cairo Univ, Fac Engn, Dept Elect Power Engn, Giza, Egypt
来源
PLOS ONE | 2024年 / 19卷 / 01期
关键词
LINE; SCHEME;
D O I
10.1371/journal.pone.0296773
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Interconnected transmission systems are increasingly spreading out in HV networks to enhance system efficiency, decrease reserve capacity, and improve service reliability. However, the protection of multi-terminal lines against Broken Conductor Fault (BCF) imposes significant difficulties in such networks as the conventional distance relays cannot detect BCF, as the BCF is not associated with a significant increase in current or reduction in voltage Traditionally, the earth fault relays in transmission lines may detect such fault; Nonetheless, it suffers from a long delay time. Moreover, many of the nearby earth fault relays detect the BCF causing unnecessary trips and badly affecting the system stability. In this article, a novel single-end scheme based on extracting transient features from current signals by discrete wavelet transform (DWT) is proposed for detecting BCFs in interconnected HV transmission systems. The suggested scheme unit (SSU) is capable of accurately detecting all types of BCFs and shunt high impedance faults (SHIFs). It also adaptively calculates the applied threshold values. The accurate selectivity in multi-terminal lines is achieved based on a fault directional element by analyzing transient power polarity. The SSU discriminates between internal/external faults effectively utilizing the time difference observed between the first spikes of aerial and ground modes in the current signals. Different fault scenarios have been simulated on the IEEE 9-Bus, 230 kV interconnected system. The achieved results confirm the effectiveness, robustness, and reliability of SSU in detecting correctly BCFs as well as the SHIFs within only 24.5 ms. The SSU has confirmed its capability to be implemented in interconnected systems without any requirement for communication or synchronization between the SSU installed in multi-terminal lines.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Classification of Lightning and Faults in Transmission Line Systems Using Discrete Wavelet Transform
    Chiradeja, Pathomthat
    Ngaopitakkul, Atthapol
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [2] Detection of Transmission Line Faults Using Discrete Wavelet Transform
    Devi, Suman
    Swarnkar, Nagendra K.
    Ola, Sheesh Ram
    Mahela, Om Prakash
    2016 CONFERENCE ON ADVANCES IN SIGNAL PROCESSING (CASP), 2016, : 133 - 138
  • [3] The Application of Discrete Wavelet Transform to Classification of Power Transmission System Faults
    Matarweh, Julie
    Mustaklem, Reziq
    Saleem, Anas
    Mohamed, Omar
    2019 IEEE JORDAN INTERNATIONAL JOINT CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION TECHNOLOGY (JEEIT), 2019, : 699 - 704
  • [4] Transmission Line Faults Detection, Classification, and Location Using Discrete Wavelet Transform
    Saravanababu, K.
    Balakrishnan, P.
    Sathiyasekar, K.
    2013 INTERNATIONAL CONFERENCE ON POWER, ENERGY AND CONTROL (ICPEC), 2013, : 233 - 238
  • [5] Faults Detection and Classification of HVDC Transmission Lines of using Discrete Wavelet Transform
    Saleem, Umar
    Arshad, Usman
    Masood, Bilal
    Gul, Talha
    Khan, Waheeed Aftab
    Ellahi, Manzoor
    2018 INTERNATIONAL CONFERENCE ON ENGINEERING & EMERGING TECHNOLOGIES (ICEET), 2018, : 99 - 104
  • [6] Real-Time Classification of Transmission Line Faults Based on Maximal Overlap Discrete Wavelet Transform
    Costa, F. B.
    Souza, B. A.
    Brito, N. S. D.
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [7] Discrete wavelet transform and support vector machine-based parallel transmission line faults classification
    Saber, Ahmed
    Emam, Ahmed
    Amer, Rabah
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 11 (01) : 43 - 48
  • [8] Discrete Wavelet Transform Based Fault Analysis and Identification in Flexible HVDC Transmission System
    Zhou, ZhiGuo
    Jin, QiYing
    Zhang, Yi
    PROCEEDINGS OF THE 2015 INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS, 2015, 40 : 799 - 803
  • [9] Identification of Faults in PV Array using Maximal Overlap Discrete Wavelet Transform
    Sreelakshmy, J.
    Kumar, B. Pradeep
    Ilango, G. Saravana
    Nagamani, C.
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [10] Discrete wavelet transform and probabilistic neural networks algorithm for identification of fault locations on transmission systems
    Ngaopitakkul, A
    Kunakorn, A
    Bunjongjit, S
    2004 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - POWERCON, VOLS 1 AND 2, 2004, : 270 - 274