Sphygmomanometer Dynamic Pressure Measurement Using a Condenser Microphone

被引:0
作者
Tomazini, Zan [1 ]
Gersak, Gregor [1 ]
Begus, Samo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
RF microphone; blood pressure; low frequency; oscillometric; BP simulator; CALIBRATION; HYPERTENSION;
D O I
10.3390/s23198340
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a worldwide need to improve blood pressure (BP) measurement error in order to correctly diagnose hypertension. Cardiovascular diseases cause 17.9 million deaths annually and are a substantial monetary strain on healthcare. The current measurement uncertainty of 3 mmHg should be improved upon. Dynamic pressure measurement standards are lacking or non-existing. In this study we propose a novel method of measuring air pressure inside the sphygmomanometer tubing during BP measurement using a condenser microphone. We designed, built, and tested a system that uses a radiofrequency (RF) modulation method to convert changes in capacitance of a condenser microphone into pressure signals. We tested the RF microphone with a low-frequency (LF) sound source, BP simulator and using a piezoresistive pressure sensor as a reference. Necessary tests were conducted to assess the uncertainty budget of the system. The RF microphone prototype has a working frequency range from 0.5 Hz to 280 Hz in the pressure range from 0 to 300 mmHg. The total expanded uncertainty (k = 2, p = 95.5%) of the RF microphone was 4.32 mmHg. The proposed method could establish traceability of BP measuring devices to acoustic standards described in IEC 61094-2 and could also be used in forming dynamic BP standards.
引用
收藏
页数:15
相关论文
共 40 条
[11]  
G.R.A.S Low-Frequency Calibrator Type 42AE, About us
[12]  
Gerak G., 2021, Meas. Sens, V18, P100260, DOI [10.1016/j.measen.2021.100260, DOI 10.1016/J.MEASEN.2021.100260]
[13]   A procedure for evaluation of non-invasive blood pressure simulators [J].
Gersak, Gregor ;
Zemva, Ales ;
Drnovsek, Janko .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (12) :1221-1228
[14]  
grasacoustics, Frequency Range of a Microphone
[15]  
Hjelmgren J., 2002, Dynamic Measurement of PressureA Literature Survey, V34
[16]   Hypertension and cardiovascular risk: General aspects [J].
Kjeldsen, Sverre E. .
PHARMACOLOGICAL RESEARCH, 2018, 129 :95-99
[17]  
Lewis J., Understanding Microphone Sensitivity
[18]  
Lia JF, 1996, J ACOUST SOC AM, V99, P969, DOI 10.1121/1.414625
[19]   The meaning of blood pressure [J].
Magder, S. .
CRITICAL CARE, 2018, 22
[20]   THE NORMAL BLOOD PRESSURE RANGE AND ITS CLINICAL IMPLICATIONS [J].
MASTER, AM ;
DUBLIN, LI ;
MARKS, HH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1950, 143 (17) :1464-1470