3D assessment of the nasolabial region in cleft models comparing an intraoral and a facial scanner to a validated baseline

被引:9
作者
Olmos, Manuel [1 ]
Matta, Ragai [2 ]
Buchbender, Mayte [1 ]
Jaeckel, Fabian [1 ]
Nobis, Christopher-Philipp [1 ]
Weber, Manuel [1 ]
Kesting, Marco [1 ]
Lutz, Rainer [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Dept Oral & Cranio Maxillofacial Surg, Glueckstr 11, D-91054 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Prosthodont, Erlangen, Germany
关键词
ARCH IMPRESSIONS; ACCURACY; LIP; SYSTEMS; PLACEMENT;
D O I
10.1038/s41598-023-39352-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We aimed to validate the metric accuracy of a 3-dimensional (3D) facial scanner (FS) and an intraoral scanner (IOS) in capturing the nasolabial region in ex vivo unilateral cleft lip and palate (UCLP) models. The nasolabial region of 10 UCLP models was scanned using a 3D FS as well as an IOS and a previously validated stationary 3D scanner as a reference. Intraoral scan was performed directly on the UCLP models. In order to apply the FS on the models, they were embedded in a 3D printed sample face. Both test groups were aligned to the reference by applying a section-based best-fit algorithm. Subsequent analysis of the metric deviation from the reference was performed with a 3D analysis tool. Mean distance and integrated distance served as main parameters for surface and volume comparison. Point comparison served as an additional parameter. Statistical analysis was carried out using t-test for unconnected samples. Considering mean distance and integrated distance as main parameters for 3D evaluation of the scanner's accuracy, FS and IOS differ significantly in their metric precision in scanning the cleft model compared to the reference. The IOS proved to be significantly more accurate than the FS compared to the previously described stationary 3D scanner as reference and validated baseline. Further validation of the tested IOS and FS for 3D assessment of the nasolabial region is presented by adding the previously validated ATOS III Triple Scan blue light scanner as a reference. The IOS shows, compared to a validated baseline scan, significantly higher metric precision in experimental cleft model scanning. The collected data provides a basis for clinical application of the IOS for 3D assessment of the nasolabial region.
引用
收藏
页数:8
相关论文
共 37 条
[1]   Methods of assessment of cleft-related facial deformity: A review [J].
Al-Omari, I ;
Millett, DT ;
Ayoub, AF .
CLEFT PALATE-CRANIOFACIAL JOURNAL, 2005, 42 (02) :145-156
[2]   The Validation of an Innovative Method for 3D Capture and Analysis of the Nasolabial Region in Cleft Cases [J].
Ayoub, Ashraf ;
Khan, Adil ;
Aldhanhani, Ali ;
Alnaser, Hashim ;
Naudi, Kurt ;
Ju, Xiangyang ;
Gillgrass, Toby ;
Mossey, Peter .
CLEFT PALATE-CRANIOFACIAL JOURNAL, 2021, 58 (01) :98-104
[3]   3D Assessment of Lip Scarring and Residual Dysmorphology Following Surgical Repair of Cleft Lip and Palate: A Preliminary Study [J].
Ayoub, Ashraf ;
Bell, Aileen ;
Simmons, David ;
Bowman, Adrian ;
Brown, Denise ;
Lo, Tsz-Wai ;
Xiao, Yijun .
CLEFT PALATE-CRANIOFACIAL JOURNAL, 2011, 48 (04) :379-387
[4]  
Bajoghli Farshad, 2015, J Int Oral Health, V7, P12
[5]   Reliability of 3D Stereophotogrammetry for Measuring Postoperative Facial Swelling [J].
Buitenhuis, Margje B. ;
Klijn, Reinoud J. ;
Rosenberg, Antoine J. W. P. ;
Speksnijder, Caroline M. .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
[6]   Long-Term Outcomes for Adult Patients With Cleft Lip and Palate [J].
Connolly, Katharine A. ;
Kurnik, Nicole M. ;
Truong, Tuan A. ;
Muller, Cristiane ;
Beals, Patricia H. ;
Singh, Davinder J. ;
Beals, Stephen P. .
JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (07) :2048-2051
[7]   Validation of the Hubli Grading System for Assessing Unilateral and Bilateral Cleft Lip Outcomes [J].
Davis, Matthew J. ;
Volk, Angela S. ;
Desai, Priya K. ;
Rumprecht, Ewa ;
Hubli, Eric .
JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (06) :E580-E584
[8]  
de Andrade GS., 2022, J PROSTHET DENT, DOI [10.1016/j.prosdent.2022.05.001, DOI 10.1016/J.PROSDENT.2022.05.001]
[9]  
Ender A, 2019, INT J COMPUT DENT, V22, P11
[10]   An Innovative Assessment of the Dynamics of Facial Movements in Surgically Managed Unilateral Cleft Lip and Palate Using 4D Imaging [J].
Gattani, Shyam ;
Ju, Xiangyang ;
Gillgrass, Toby ;
Bell, Aileen ;
Ayoub, Ashraf .
CLEFT PALATE-CRANIOFACIAL JOURNAL, 2020, 57 (09) :1125-1133