Axial tension/compression and torsional loading of diamond and gyroid lattice structures for biomedical implants: Simulation and experiment

被引:23
|
作者
Timercan, Anatolie [1 ]
Terriault, Patrick [1 ]
Brailovski, Vladimir [1 ]
机构
[1] Ecole technol Super, Dept Mech Engn, 1100 Notre Dame West, Montreal, PQ H3C 1K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Lattice structure; Compression; Tension; Torsion; Numerical modeling; Experimental validation; TRABECULAR BONE; CORTICAL BONE; STRENGTH; SCAFFOLDS; DENSITY; DESIGN;
D O I
10.1016/j.matdes.2022.111585
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Lattice structures are increasingly used in biomedical implants, notably intervertebral cages, requiring a better understanding of their behavior for the different types of loading they undergo during application. Strut-based diamond and sheet-based gyroid structures with porosity levels ranging from 50 to 80 % and an identical pore size of 750 lm were manufactured from Ti6Al4V alloy, tested experimentally and sim-ulated numerically in axial tension/compression and in torsion to simulate flexion/extension, compres-sion and rotation of the human spine. The manufactured structures were within 5 % of the targeted porosity. However, numerical simulations overestimated the experimental apparent (effective) stiffness and strength of the structures by an average of 25 %, likely due to the presence in them of manufacturing defects, especially in the higher porosity lattices. Experimental and numerical results showed that the structures have quasi-identical mechanical properties in compression and in tension. However, a com-parison of the torsion and axial results indicated that conventional bulk material failure theories such as the von Mises limitation criterion do not apply to the apparent properties of lattice structures. Studied lattices exhibited adequate resistance for use in intervertebral cages, however their stiffness was greater than those of the vertebrae, while situated in the stiffness range of cortical bone.& COPY; 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:15
相关论文
共 6 条
  • [1] Energy absorption of diamond lattice cylindrical shells under axial compression loading
    Zhu, Huaiming
    Wang, Peng
    Wei, Dong
    Si, Jianfeng
    Wu, Yaozhong
    THIN-WALLED STRUCTURES, 2022, 181
  • [2] Energy absorption of diamond lattice cylindrical shells under axial compression loading
    Zhu, Huaiming
    Wang, Peng
    Wei, Dong
    Si, Jianfeng
    Wu, Yaozhong
    Thin-Walled Structures, 2022, 181
  • [3] Additive manufactured gyroid-based cell structures under compression: design, testing and simulation for biomedical applications
    Carlos Castro-Sandoval, Juan
    Chavez, Alfredo
    Corona-Castuera, Jorge
    Henao, John
    Antonio Rivera-Gil, Marco
    Poblano-Salas, Carlos A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (02) : 211 - 221
  • [4] A new form of equivalent stress for combined axial-torsional loading considering the tension-compression asymmetry of polymeric materials
    Zhang, Jianwei
    Jiang, Han
    Kang, Guozheng
    Jiang, Chengkai
    Lu, Fucong
    RSC ADVANCES, 2015, 5 (89): : 72780 - 72784
  • [5] Mechanical behavior and failure mode of body-centered cubic, gyroid, diamond, and Voronoi functionally graded additively manufactured biomedical lattice structures
    Cheloni, Joao Pedro M.
    Zluhan, Bruno
    Silveira, Marcio E.
    Fonseca, Eduardo B.
    Valim, Diego B.
    Lopes, Eder S. N.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 163
  • [6] Assessing the compressive and tensile properties of TPMS-Gyroid and stochastic Ti64 lattice structures: A study on laser powder bed fusion manufacturing for biomedical implants
    Araya, Miguel
    Jaskari, Matias
    Rautio, Timo
    Guillen, Teodolito
    Jarvenpaa, Antti
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2024, 9 (01):