Biomechanical comparative study of midline cortical vs. traditional pedicle screw trajectory in osteoporotic bone

被引:1
作者
Schleifenbaum, Stefan [1 ,2 ]
Vogl, Ann-Cathrin [1 ,2 ]
Heilmann, Robin [1 ,2 ]
von der Hoeh, Nicolas Heinz [1 ]
Heyde, Christoph-Eckhard [1 ,2 ]
Jarvers, Jan-Sven [1 ]
机构
[1] Univ Leipzig, Dept Orthoped Trauma & Plast Surg, Liebigstr 20, D-04103 Leipzig, Germany
[2] ZESBO Zent Erforschung Stuetz & Bewegungsorgane, Semmelweisstr 14, D-04103 Leipzig, Germany
关键词
Cortical bone trajectory (CBT); Biomechanical analysis; MC; Osteoporosis; Patient-specific placement guide; POLYMETHYLMETHACRYLATE AUGMENTATION; SURGICAL-TREATMENT; FIXATION STRENGTH; SPINE; OUTCOMES;
D O I
10.1186/s12891-023-06502-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionIn lumbar spinal stabilization pedicle screws are used as standard. However, especially in osteoporosis, screw anchorage is a problem. Cortical bone trajectory (CBT) is an alternative technique designed to increase stability without the use of cement. In this regard, comparative studies showed biomechanical superiority of the MC (midline cortical bone trajectory) technique with longer cortical progression over the CBT technique. The aim of this biomechanical study was to comparatively investigate the MC technique against the not cemented pedicle screws (TT) in terms of their pullout forces and anchorage properties during sagittal cyclic loading according to the ASTM F1717 test.MethodsFive cadavers (L1 to L5), whose mean age was 83.3 +/- 9.9 years and mean T Score of -3.92 +/- 0.38, were dissected and the vertebral bodies embedded in polyurethane casting resin. Then, one screw was randomly inserted into each vertebra using a template according to the MC technique and a second one was inserted by freehand technique with traditional trajectory (TT). The screws were quasi-static extracted from vertebrae L1 and L3, while for L2, L4 and L5 they were first tested dynamically according to ASTM standard F1717 (10,000 cycles at 1 Hz between 10 and 110 N) and then quasi-static extracted. In order to determine possible screw loosening, there movements were recorded during the dynamic tests using an optical measurement system.ResultsThe pull-out tests show a higher pull-out strength for the MC technique of 555.4 +/- 237.0 N compared to the TT technique 448.8 +/- 303.2 N. During the dynamic tests (L2, L4, L5), 8 out of the 15 TT screws became loose before completing 10,000 cycles. In contrast, all 15 MC screws did not exceed the termination criterion and were thus able to complete the full test procedure. For the runners, the optical measurement showed greater relative movement of the TT variant compared to the MC variant. The pull-out tests also revealed that the MC variant had a higher pull-out strength, measuring at766.7 +/- 385.4 N, while the TT variant measured 637.4 +/- 435.6 N.ConclusionThe highest pullout forces were achieved by the MC technique. The main difference between the techniques was observed in the dynamic measurements, where the MC technique exhibited superior primary stability compared to the conventional technique in terms of primary stability. Overall, the MC technique in combination with template-guided insertion represents the best alternative for anchoring screws in osteoporotic bone without cement.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Augmentation of Pedicle Screw Stability With Calcium Sulfate Cement in Osteoporotic Sheep Biomechanical and Screw-bone Interfacial Evaluation
    Liu, Da
    Lei, Wei
    Wu, Zi-xiang
    Gao, Ming-xuan
    Wan, Shi-yong
    Fu, Suo-chao
    Shi, Lei
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (04): : 235 - 241
  • [22] Isthmus-guided Cortical Bone Trajectory for Pedicle Screw Insertion
    Iwatsuki, Koichi
    Yoshimine, Toshiki
    Ohnishi, Yu-ichiro
    Ninomiya, Kosi
    Ohkawa, Toshika
    ORTHOPAEDIC SURGERY, 2014, 6 (03) : 244 - 248
  • [23] Biomechanical evaluation of lumbar pedicle screws in spondylolytic vertebrae: comparison of fixation strength between the traditional trajectory and a cortical bone trajectory
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Asazuma, Takashi
    Chiba, Kazuhiro
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (06) : 910 - 915
  • [24] Biomechanical Fixation Properties of the Cortical Bone Trajectory in the Osteoporotic Lumbar Spine
    Li, Hui-Min
    Zhang, Ren-Jie
    Gao, Hai
    Jia, Chong-Yu
    Xing, Tao
    Zhang, Jian-Xiang
    Dong, Fu-Long
    Shen, Cai-Liang
    WORLD NEUROSURGERY, 2018, 119 : E717 - E727
  • [25] Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws
    Chen, Yi-Long
    Chen, Wen-Chuan
    Chou, Chi-Wei
    Chen, Jou-Wen
    Chang, Chia-Ming
    Lai, Yu-Shu
    Cheng, Cheng-Kung
    Wang, Shih-Tien
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1416 - 1420
  • [26] A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation
    Fu, Suochao
    Zhang, Yu
    Ai, Fuzhi
    Wang, Jianhua
    Wu, Zenghui
    Ma, Xiangyang
    Wu, Zixiang
    Wang, Zheng
    Lei, Wei
    Xia, Hong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [27] Biomechanical Evaluation of a Novel Fenestrated Pedicle Screw Augmented With Bone Cement in Osteoporotic Spines
    Pare, Philippe E.
    Chappuis, James L.
    Rampersaud, Raja
    Agarwala, Amit O.
    Perra, Joseph H.
    Erkan, Serkan
    Wu, Chunhui
    SPINE, 2011, 36 (18) : E1210 - E1214
  • [28] Cortical bone trajectory screws used to save failed traditional trajectory screws in the osteoporotic lumbar spine and vice versa: a human cadaveric biomechanical study
    Zhang, Ren-Jie
    Li, Hui-Min
    Gao, Hai
    Jia, Chong Yu
    Xing, Tao
    Dong, Fu-Long
    Shen, Cai-Liang
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 30 (06) : 759 - 766
  • [29] Comparative Study of Cortical Bone Trajectory-Pedicle Screw (Cortical Screw) Versus Conventional Pedicle Screw in Single-Level Posterior Lumbar Interbody Fusion: A 2-Year Post Hoc Analysis from Prospectively Randomized Data
    Lee, Gun Woo
    Ahn, Myun-Whan
    WORLD NEUROSURGERY, 2018, 109 : E194 - E202
  • [30] Comparative clinical efficacy and safety of cortical bone trajectory screw fixation and traditional pedicle screw fixation in posterior lumbar fusion: a systematic review and meta-analysis
    Wang, Jizhou
    He, Xiaoqi
    Sun, Tianwei
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1678 - 1689