The modification of bone cut angle and joint line obliquity did not change the tibiofemoral kinematics and stability of knee joint after total knee arthroplasty

被引:0
作者
Minoda, Yukihide [1 ]
Sugama, Ryo [1 ]
Ohta, Yoichi [1 ]
Ohyama, Yohei [1 ]
Masuda, Sho [1 ]
Ikebuchi, Mitsuhiko [1 ]
Nakamura, Hiroaki [1 ]
机构
[1] Osaka Metropolitan Univ, Dept Orthopaed Surg, Grad Sch Med, 1-4-3 Asahi Machi Abeno Ku, Osaka 5458585, Japan
关键词
Total knee arthroplasty; Joint line obliquity; Tibiofemoral kinematics; ALIGNED TOTAL KNEE; VIVO FLUOROSCOPIC ANALYSIS; FOLLOW-UP; ALIGNMENT; OUTCOMES; STRESS; MOTION; TKA;
D O I
10.1007/s00402-023-04899-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionPrevious reports using cadaveric knees and musculoskeletal computer simulation have shown that kinematically aligned (KA) total knee arthroplasty (TKA) provides more natural and physiological tibiofemoral kinematic patterns than mechanically aligned (MA) TKA. These reports suggested that the modification of joint line obliquity improve the knee kinematics. This study aimed to determine whether joint line obliquity change the intraoperative tibiofemoral kinematics in TKA candidates with knee osteoarthritis.MethodsThirty consecutive knees with varus osteoarthritis that underwent TKA using a navigation system were evaluated. Two types of trial components were prepared: (1) MA TKA model: component trial in which articulating surface was parallel to the bone cut surface (2) KA TKA model: the femoral component trial, which mimicked the KA TKA method of Dossett et al. was designed 3 degrees valgus and 3 degrees internal rotation to the femoral bone cut surface, and the tibial component trial was designed 3 degrees varus to the tibial bone cut surface. These two trials were set on the same knees during the operation, and the tibiofemoral rotational kinematics and varus-valgus laxity were measured from 0 degrees to 120 degrees of knee flexion using a navigation system.ResultsThe joint gap was 20 +/- 2 mm and 3 degrees +/- 1 degrees varus in extension and 20 +/- 2 mm and 3 degrees +/- 1 degrees varus in flexion. The differences in femoral component rotation between KA TKA and MA TKA were not statistically significant for any knee flexion angle. The differences in varus-valgus laxity between KA TKA and MA TKA were also not statistically significant for any knee flexion angle.ConclusionAlthough the degree of joint line obliquity varies widely in various KA TKA methods, this study, which mimicked the method of Dossett et al. showed that the modification of joint line obliquity did not change the tibiofemoral kinematics and stability of the knee joint in TKA candidates with knee osteoarthritis.
引用
收藏
页码:6345 / 6351
页数:7
相关论文
共 24 条
[21]   Intraoperative Medial Pivot Affects Deep Knee Flexion Angle and Patient-Reported Outcomes After Total Knee Arthroplasty [J].
Nishio, Yusuke ;
Onodera, Tomohiro ;
Kasahara, Yasuhiko ;
Takahashi, Daisuke ;
Iwasaki, Norimasa ;
Majima, Tokifumi .
JOURNAL OF ARTHROPLASTY, 2014, 29 (04) :702-706
[22]   Long-term follow-up of a non-randomised prospective cohort of one hundred and ninety two total knee arthroplasties using the NexGen implant [J].
Panni, Alfredo Schiavone ;
Falez, Franceso ;
D'Apolito, Rocco ;
Corona, Katia ;
Perisano, Carlo ;
Vasso, Michele .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (06) :1155-1162
[23]   Why Are Total Knees Failing Today? Etiology of Total Knee Revision in 2010 and 2011 [J].
Schroer, William C. ;
Berend, Keith R. ;
Lombardi, Adolph V. ;
Barnes, C. Lowry ;
Bolognesi, Michael P. ;
Berend, Michael E. ;
Ritter, Merrill A. ;
Nunley, Ryan M. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :116-119
[24]   Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis [J].
Tsubosaka, Masanori ;
Ishida, Kazunari ;
Kodato, Kazuki ;
Shibanuma, Nao ;
Hayashi, Shinya ;
Kurosaka, Masahiro ;
Kuroda, Ryosuke ;
Matsumoto, Tomoyuki .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (02) :467-473