Dosimetric Parameters in Hypofractionated Stereotactic Radiotherapy for Brain Metastases: Do Flattening Filter-Free Beams Bring Benefits? A Preliminary Study

被引:1
作者
Ghemis, Diana M. [1 ,2 ]
Marcu, Loredana G. [1 ,3 ,4 ]
机构
[1] West Univ Timisoara, Fac Phys, Timisoara 300223, Romania
[2] MedEuropa, Oradea 410191, Romania
[3] Univ Oradea, Fac Informat & Sci, Oradea 410087, Romania
[4] Univ South Australia, Canc Res Inst, Adelaide 5001, Australia
关键词
hypofractionation; stereotactic radiotherapy; brain metastases; flattening filter-free beam; MODULATED ARC THERAPY; 5 DAILY FRACTIONS; RADIATION-THERAPY; RADIOSURGERY; SINGLE; CONFORMITY; NECROSIS; SURGERY; INDEX;
D O I
10.3390/cancers15030678
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The use of flattening filter-free beams (FFF) in stereotactic radiotherapy has increased in recent years due to their dosimetric and clinical benefits. This study evaluated and compared two treatment plans (one employing FFF beams and one with optimized flattened beams) for eighteen patients treated with hypofractionated stereotactic radiotherapy for brain metastasis. Physical and dosimetric parameters were analyzed, resulting in no significant differences regarding the number of monitor units, conformity index (p = 0.28), dose gradient index (p = 0.4) and dose to normal brain tissue (p = 0.51). The average difference in target coverage was 1.26%, with lower doses for treatment plans where FF beams were employed (p = 0.03). Beam on time was significantly reduced for FFF beams (p <= 0.001). Purpose: This study aimed to compare the dosimetric results of flattening filter-free (FFF) vs. flattened (FF) treatment plans for fractionated stereotactic radiotherapy (fSRT), with the goal to highlight potential advantages of FFF beams. Methods: A group of 18 patients with brain metastases treated with fSRT (30 Gy delivered in 5 fractions) were included. The dosimetric parameters evaluated were: (1) physical dosimetric parameters (number of monitor units (MUs), conformity index (CI), dose gradient index (DGI), beam on time (BOT)); (2) clinical dosimetric parameters pertaining to target volume (PTV) and organs at risk (OARs). Two treatment plans were performed for all patients: one used 6 MV FFF beams and the other used 6 MV flattened beams. Results: A slight increase in MUs was observed for the FFF mode (+23.3 MUs). The CI showed a difference of -2.7% for the FF plans (p = 0.28), correlated with a poorer coverage of the PTV. DGI values reported in terms of PTV are in line with international recommendations and showed a +1.9% difference for FFF plans. An average BOT of 90.3 s was reported for FFF plans, which was 2.3 times shorter than that required for FF plans delivery (p <= 0.001). A slight decrease of PTV coverage (-1.26%, p = 0.036) for FF plans can be considered relevant, but no other significant differences were observed between the two optimizations. No statistically significant benefit of using FFF beams to reduce V-20 for normal brain could be demonstrated. Conclusion: These dosimetric results encourage the implementation of fSRT with standard flattened beams in centers where FFF linacs are not available.
引用
收藏
页数:12
相关论文
共 31 条
[1]  
Ahmed Zain, 2014, CNS Oncol, V3, P199, DOI 10.2217/cns.14.18
[2]   Hypofractionated Stereotactic Radiotherapy in Five Daily Fractions for Post-Operative Surgical Cavities in Brain Metastases Patients With and Without Prior Whole Brain Radiation [J].
Al-Omair, Ameen ;
Soliman, Hany ;
Xu, Wei ;
Karotki, Aliaksandr ;
Mainprize, Todd ;
Nicolas Phan ;
Das, Sunit ;
Keith, Julia ;
Yeung, Robert ;
Perry, James ;
Tsao, May ;
Sahgal, Arjun .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) :493-499
[3]   Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial [J].
Andrews, DW ;
Scott, CB ;
Sperduto, PW ;
Flanders, AE ;
Gaspar, LE ;
Schell, MC ;
Werner-Wasik, M ;
Demas, W ;
Ryu, J ;
Bahary, JP ;
Souhami, L ;
Rotman, M ;
Mehta, MP ;
Curran, WJ .
LANCET, 2004, 363 (9422) :1665-1672
[4]   Dosimetric predictors of symptomatic radiation necrosis after five-fraction radiosurgery for brain metastases [J].
Andruska, Neal ;
Kennedy, William R. ;
Bonestroo, Liberty ;
Anderson, Rebecca ;
Huang, Yi ;
Robinson, Clifford G. ;
Abraham, Christopher ;
Tsien, Christina ;
Knutson, Nels ;
Rich, Keith M. ;
Spencer, Christopher ;
Huang, Jiayi .
RADIOTHERAPY AND ONCOLOGY, 2021, 156 :181-187
[5]   Brain metastasis [J].
Boire, Adrienne ;
Brastianos, Priscilla K. ;
Garzia, Livia ;
Valiente, Manuel .
NATURE REVIEWS CANCER, 2020, 20 (01) :4-11
[6]   Postoperative stereotactic radiosurgery compared with whole brain radiotherapy for resected metastatic brain disease (NCCTG N107C/CEC.3): a multicentre, randomised, controlled, phase 3 trial [J].
Brown, Paul D. ;
Ballman, Karla V. ;
Cerhan, Jane H. ;
Anderson, S. Keith ;
Carrero, Xiomara W. ;
Whitton, Anthony C. ;
Greenspoon, Jeffrey ;
Parney, Ian F. ;
Laack, Nadia N. I. ;
Ashman, Jonathan B. ;
Bahary, Jean-Paul ;
Hadjipanayis, Costas G. ;
Urbanic, James J. ;
Barker, Fred G., II ;
Farace, Elana ;
Khuntia, Deepak ;
Giannini, Caterina ;
Buckner, Jan C. ;
Galanis, Evanthia ;
Roberge, David .
LANCET ONCOLOGY, 2017, 18 (08) :1049-1060
[7]   Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial [J].
Chang, Eric L. ;
Wefel, Jeffrey S. ;
Hess, Kenneth R. ;
Allen, Pamela K. ;
Lang, Frederick F. ;
Kornguth, David G. ;
Arbuckle, Rebecca B. ;
Swint, J. Michael ;
Shiu, Almon S. ;
Maor, Moshe H. ;
Meyers, Christina A. .
LANCET ONCOLOGY, 2009, 10 (11) :1037-1044
[8]   Radiation necrosis following gamma knife surgery: a case-controlled comparison of treatment parameters and long-term clinical follow up [J].
Chin, LS ;
Ma, LJ ;
DiBiase, S .
JOURNAL OF NEUROSURGERY, 2001, 94 (06) :899-904
[9]   Planning study and dose measurements of intracranial stereotactic radiation surgery with a flattening filter-free linac [J].
Dzierma, Yvonne ;
Nuesken, Frank G. ;
Palm, Jan ;
Licht, Norbert P. ;
Ruebe, Christian .
PRACTICAL RADIATION ONCOLOGY, 2014, 4 (02) :E109-E116
[10]  
Elekta IMPAC Medical System Inc., 2015, LTGMON0510 EL IMPAC, P854