Revisiting sample size planning for receiver operating characteristic studies: A confidence interval approach with precision and assurance

被引:4
作者
Shu, Di [1 ,2 ,3 ,6 ]
Zou, Guangyong [4 ,5 ]
机构
[1] Univ Penn, Perelman Sch Med, Dept Biostat Epidemiol & Informat, Philadelphia, PA USA
[2] Univ Penn, Perelman Sch Med, Dept Pediat, Philadelphia, PA USA
[3] Childrens Hosp Philadelphia, Clin Futures, Philadelphia, PA USA
[4] Western Univ, Schulich Sch Med & Dent, Dept Epidemiol & Biostat, London, ON, Canada
[5] Western Univ, Robarts Res Inst, London, ON, Canada
[6] Univ Penn, Perelman Sch Med, Dept Biostat Epidemiol & Informat, 423 Guardian Dr, Philadelphia, PA 19104 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Area under receiver operating characteristic curve; assurance probability; confidence interval; diagnostic study; sample size estimation; DIAGNOSTIC PERFORMANCE; CHARACTERISTIC CURVES; AREAS; DIFFERENCE; CHOICE;
D O I
10.1177/09622802231151210
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Estimation of areas under receiver operating characteristic curves and their differences is a key task in diagnostic studies. Here we develop closed-form sample size formulas for such studies with a focus on estimation rather than hypothesis testing, by explicitly incorporating pre-specified precision and assurance, with precision denoted by the lower limit of confidence interval and assurance denoted by the probability of achieving that lower limit. For sample size estimation purposes, we introduce a normality-based variance function for valid estimation allowing for unequal variances of observations in the disease and non-disease groups. Simulation results demonstrate that the proposed formulas produce empirical assurance probability close to the pre-specified assurance probability and empirical coverage probability close to the nominal level. Compared with a frequently used existing variance function, the proposed function provides more accurate and efficient sample size estimates. For an illustration of the proposed formulas, we present real-world worked examples. To facilitate implementation, we have developed an online calculator openly available at .
引用
收藏
页码:748 / 759
页数:12
相关论文
共 37 条
  • [1] [Anonymous], SAMPLE SIZE CALCULAT
  • [2] AREA ABOVE ORDINAL DOMINANCE GRAPH AND AREA BELOW RECEIVER OPERATING CHARACTERISTIC GRAPH
    BAMBER, D
    [J]. JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1975, 12 (04) : 387 - 415
  • [4] Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy
    Biglands, John D.
    Magee, Derek R.
    Sourbron, Steven P.
    Plein, Sven
    Greenwood, John P.
    Radjenovic, Aleksandra
    [J]. RADIOLOGY, 2015, 275 (02) : 393 - 402
  • [5] Confidence intervals for standardized linear contrasts of means
    Bonett, Douglas G.
    [J]. PSYCHOLOGICAL METHODS, 2008, 13 (02) : 99 - 109
  • [6] Bossuyt PM, 2015, BMJ-BRIT MED J, V351, DOI [10.1136/bmj.h5527, 10.1373/clinchem.2015.246280, 10.1148/radiol.2015151516]
  • [7] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [8] Partial AUC estimation and regression
    Dodd, LE
    Pepe, MS
    [J]. BIOMETRICS, 2003, 59 (03) : 614 - 623
  • [9] Relationship of Temporal Resolution to Diagnostic Performance for Dynamic Contrast Enhanced MRI of the Breast
    El Khouli, Riham H.
    Macura, Katarzyna J.
    Barker, Peter B.
    Habba, Mohamed R.
    Jacobs, Michael A.
    Bluemke, David A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 999 - 1004
  • [10] Sample size calculation should be performed for design accuracy in diagnostic test studies
    Flahault, A
    Cadilhac, M
    Thomas, G
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (08) : 859 - 862