Variability in Cardiopulmonary Exercise Testing Biologic Controls

被引:1
|
作者
DeCato, Thomas W. [1 ,2 ,3 ,7 ]
Haverkamp, Hans C. [4 ]
Gooding, Thomas [4 ]
Collingridge, Dave S. [5 ]
Hegewald, Matthew J. [5 ,6 ]
机构
[1] Harbor UCLA Med Ctr, Div Resp & Crit Care Physiol & Med, Torrance, CA USA
[2] Harbor UCLA Med Ctr, Lundquist Inst Biomed Innovat, Torrance, CA USA
[3] Washington State Univ, Elson S Floyd Coll Med, Dept Med Educ & Clin Sci, Spokane, WA USA
[4] Washington State Univ, Elson S Floyd Coll Med, Dept Nutr & Exercise Physiol, Spokane, WA USA
[5] Intermt Med Ctr, Pulm & Crit Care Med, Murray, UT USA
[6] Univ Utah, Div Resp Crit Care & Occupat Pulm Med, Salt Lake City, UT USA
[7] Harbor UCLA Med Ctr, 1000 W Carson St,CDCRC Box 402, Torrance, CA 90509 USA
关键词
cardiopulmonary exercise testing; CPET; biocontrol; quality control; REFERENCE VALUES; QUALITY-CONTROL;
D O I
10.4187/respcare.10022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Cardiopulmonary exercise testing is an increasingly common test and is consid-ered the accepted standard for assessing exercise capacity. Quantifying variability is important to assess the instrument for quality control purposes. Though guidelines recommend biologic control testing, there are minimal data on how to do it. We sought to describe variability for oxygen con-sumption (VO2), carbon dioxide production (VCO2), and minute ventilation (VE) at various work rates under steady-state conditions in multiple subjects over a 1-y period to provide a practical approach to assess and perform biologic control testing. METHODS: We performed a single-center, prospec-tive study with 4 healthy subjects, 2 men and 2 women. Subjects performed constant work rate exer-cise tests for 6 min each at 25-100 W intervals on a computer-controlled cycle ergometer. Data were averaged over the last 120 s at each work rate to reflect stepwise steady-state conditions. Descriptive statistics, including the mean, median, range, SD, and coefficient of variation (CoV) are reported for each individual across the 4 work rates and all repetitions. As these data were normative, z-scores were utilized, and a value greater than +/- 1.96 z-scores was used to define significant test variability. RESULTS: Subjects performed 16-39 biocontrol studies over 1-y. The mean CoV for all subjects in VO2 was 6.59%, VCO2 was 6.41%, and VE was 6.32%. The +/- 1.96 z-scores corresponded to a 9.4- 18.1% change in VO2 , a 9.6-18.1% change in VCO2 , and a 9-21.5% change in VE across the 4 workloads. CONCLUSIONS: We report long-term variability for steady-state measurement of VO2 , VCO2 , and VE obtained during biocontrol testing. Utilizing +/- 1.96 z-scores allows one to determine if a result exceeds expected variability, which may warrant investigation of the instrument.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Variability in cardiopulmonary exercise testing protocols in NSW and ACT
    Drury, K.
    Cavaleri, R.
    Cochrane, B.
    Anderson, C.
    Seeto, J.
    Green, S.
    RESPIROLOGY, 2024, 29 : 5 - 5
  • [2] ARTP statement on cardiopulmonary exercise testing 2021
    Pritchard, Andrew
    Burns, Paul
    Correia, Joao
    Jamieson, Patrick
    Moxon, Peter
    Purvis, Joanna
    Thomas, Maximillian
    Tighe, Hannah
    Sylvester, Karl Peter
    BMJ OPEN RESPIRATORY RESEARCH, 2021, 8 (01)
  • [3] Cardiopulmonary exercise testing
    Ulubay, Gaye
    Oner Eyuboglu, Fusun
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2006, 54 (01): : 90 - 98
  • [4] Exercise Physiology and Cardiopulmonary Exercise Testing
    Sietsema, Kathy E.
    Rossiter, Harry B.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 44 (05) : 661 - 680
  • [5] Cardiopulmonary exercise testing in the management of systemic sclerosis
    Martis, N.
    Leroy, S.
    REVUE DE MEDECINE INTERNE, 2022, 43 (08): : 498 - 505
  • [6] Cardiopulmonary Exercise Testing in the Assessment of Dysfunctional Breathing
    Ionescu, Maria F.
    Mani-Babu, Sethu
    Degani-Costa, Luiza H.
    Johnson, Martin
    Paramasivan, Chelliah
    Sylvester, Karl
    Fuld, Jonathan
    FRONTIERS IN PHYSIOLOGY, 2021, 11
  • [7] Cardiopulmonary Exercise Testing and Surgery
    Older, Paul O.
    Levett, Denny Z. H.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2017, 14 : S74 - S83
  • [8] CARDIOPULMONARY EXERCISE TESTING IN HYPERTHYROIDISM
    HELLERMANN, J
    TREESE, N
    MOHRKAHALY, S
    BEYER, J
    KAHALY, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 (01): : 38 - 43
  • [9] SUBOPTIMAL CARDIOPULMONARY EXERCISE TESTING QUALITY CONTROL PRACTICES ACROSS RESPIRATORY LABORATORIES
    Williams, T.
    Warner, J.
    RESPIROLOGY, 2019, 24 : 21 - 21
  • [10] CARDIOPULMONARY EXERCISE TESTING IN PULMONARY SARCOIDOSIS
    SCHWAIBLMAIR, M
    HETTICH, R
    FRUHMANN, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 : 163 - 168