The Voltammetric Detection of Cadaverine Using a Diamine Oxidase and Multi-Walled Carbon Nanotube Functionalised Electrochemical Biosensor

被引:5
|
作者
Amin, Mohsin [1 ]
Abdullah, Badr M. M. [1 ]
Wylie, Stephen R. R. [1 ]
Rowley-Neale, Samuel J. J. [2 ]
Banks, Craig E. E. [2 ]
Whitehead, Kathryn A. A. [3 ]
机构
[1] Liverpool John Moores Univ, Fac Engn & Technol, Liverpool L3 3AF, England
[2] Manchester Metropolitan Univ, Fac Sci & Engn, Manchester M1 5GD, England
[3] Manchester Metropolitan Univ, Microbiol Interfaces Grp, Manchester M15 6BH, England
关键词
biosensor; cadaverine; electrochemistry; multi-walled carbon nanotubes; periodontitis; BIOGENIC-AMINES; ELECTRODES; PUTRESCINE; INFLAMMATION; STRATEGIES; HISTAMINE;
D O I
10.3390/nano13010036
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cadaverine is a biomolecule of major healthcare importance in periodontal disease; however, current detection methods remain inefficient. The development of an enzyme biosensor for the detection of cadaverine may provide a cheap, rapid, point-of-care alternative to traditional measurement techniques. This work developed a screen-printed biosensor (SPE) with a diamine oxidase (DAO) and multi-walled carbon nanotube (MWCNT) functionalised electrode which enabled the detection of cadaverine via cyclic voltammetry and differential pulse voltammetry. The MWCNTs were functionalised with DAO using carbodiimide crosslinking with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N-Hydroxysuccinimide (NHS), followed by direct covalent conjugation of the enzyme to amide bonds. Cyclic voltammetry results demonstrated a pair of distinct redox peaks for cadaverine with the C-MWCNT/DAO/EDC-NHS/GA SPE and no redox peaks using unmodified SPEs. Differential pulse voltammetry (DPV) was used to isolate the cadaverine oxidation peak and a linear concentration dependence was identified in the range of 3-150 mu g/mL. The limit of detection of cadaverine using the C-MWCNT/DAO/EDC-NHS/GA SPE was 0.8 mu g/mL, and the biosensor was also found to be effective when tested in artificial saliva which was used as a proof-of-concept model to increase the Technology Readiness Level (TRL) of this device. Thus, the development of a MWCNT based enzymatic biosensor for the voltammetric detection of cadaverine which was also active in the presence of artificial saliva was presented in this study.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Preparation of voltammetric biosensor for tryptophan using multi-walled carbon nanotubes
    Majid Kia
    Akbar Islamnezhad
    Shahab Shariati
    Pouria Biparva
    Korean Journal of Chemical Engineering, 2011, 28 : 2064 - 2068
  • [2] Preparation of voltammetric biosensor for tryptophan using multi-walled carbon nanotubes
    Kia, Majid
    Islamnezhad, Akbar
    Shariati, Shahab
    Biparva, Pouria
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (10) : 2064 - 2068
  • [3] A novel multi-walled carbon nanotube-based biosensor for glucose detection
    Wang, SG
    Zhang, Q
    Wang, RL
    Yoon, SF
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 311 (03) : 572 - 576
  • [4] Amperometric biosensor for total histamine, putrescine and cadaverine using diamine oxidase
    Male, KB
    Bouvrette, P
    Luong, JHT
    Gibbs, BF
    JOURNAL OF FOOD SCIENCE, 1996, 61 (05) : 1012 - 1016
  • [5] Label-free electrochemical biosensor for ultra-low level detection of Ag(I) using ssDNA functionalized multi-walled carbon nanotube
    Pal, Chittatosh
    Majumder, Subrata
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2022, 645
  • [6] Application of Multi-walled Carbon Nanotube Modified Carbon Ionic Liquid Electrode for the Voltammetric: Detection of Dopamine
    Qu, Li-Ning
    Wu, Jie
    Sun, Xiao-Ying
    Xi, Meng-Ying
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (4A) : 701 - 707
  • [7] Bilirubin oxidase bound to multi-walled carbon nanotube-modified gold
    Schubert, Kirsten
    Goebel, Gero
    Lisdat, Fred
    ELECTROCHIMICA ACTA, 2009, 54 (11) : 3033 - 3038
  • [8] Ultralong aligned multi-walled carbon nanotube for electrochemical sensing
    Punbusayakul, Niramol
    Ci, Lijie
    Talapatra, Saikat
    Surareungchai, Werasak
    Ajayan, Pulickel M.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (04) : 2085 - 2090
  • [9] DNA-wrapped multi-walled carbon nanotube modified electrochemical biosensor for the detection of Escherichia coli from real samples
    Ozkan-Ariksoysal, Dilsat
    Kayran, Yasin Ugur
    Yilmaz, Fethiye Ferda
    Ciucu, Anton Alexandru
    David, Iulia Gabriela
    David, Vasile
    Hosgor-Limoncu, Mine
    Ozsoz, Mehmet
    TALANTA, 2017, 166 : 27 - 35
  • [10] Voltammetric determination of nifedipine using a β-cyclodextrin modified multi-walled carbon nanotube paste electrode
    Gaichore, Reena R.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1328 - 1337