Model averaging in calibration of near-infrared instruments with correlated high-dimensional data

被引:1
作者
Salaki, Deiby Tineke [1 ]
Kurnia, Anang [2 ]
Sartono, Bagus [2 ]
Mangku, I. Wayan [3 ]
Gusnanto, Arief [4 ]
机构
[1] Sam Ratulangi Univ, Dept Math, Manado, Indonesia
[2] Bogor Agr Univ, Dept Stat, Bogor, Indonesia
[3] Bogor Agr Univ, Dept Math, Bogor, Indonesia
[4] Univ Leeds, Dept Stat, Leeds LS2 9JT, W Yorkshire, England
关键词
Model averaging; high-dimensional data; multicollinearity; calibration; near-infrared spectroscopy; VARIABLE SELECTION; RIDGE-REGRESSION; LASSO;
D O I
10.1080/02664763.2022.2122947
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Model averaging (MA) is a modelling strategy where the uncertainty in the configuration of selected variables is taken into account by weight-combining each estimate of the so-called 'candidate model'. Some studies have shown that MA enables better prediction, even in high-dimensional cases. However, little is known about the model prediction performance at different types of multicollinearity in high-dimensional data. Motivated by calibration of near-infrared (NIR) instruments,we focus on MA prediction performance in such data. The weighting schemes that we consider are based on the Akaike's information criterion (AIC), Mallows' C-p, and cross-validation. For estimating the model parameters, we consider the standard least squares and the ridge regression methods. The results indicate that MA outperforms model selection methods such as LASSO and SCAD in high-correlation data. The use of Mallows' C-p and cross-validation for the weights tends to yield similar results in all structures of correlation, although the former is generally preferred. We also find that the ridge model averaging outperforms the least-squares model averaging. This research suggests ridge model averaging to build a relatively better prediction of the NIR calibration model.
引用
收藏
页码:279 / 297
页数:19
相关论文
共 50 条
[31]   Study of quantitative calibration model suitability in near-infrared spectroscopy analysis [J].
Xu, GT ;
Yuan, HF ;
Lu, WZ .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (04) :459-463
[32]   Effect of Wavelength Drift on PLSR Calibration Model of Near-Infrared Spectroscopy [J].
Lu Qi-peng ;
Wang Dong-min ;
Song Yuan ;
Ding Hai-quan ;
Gao Hong-zhi .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (02) :405-409
[33]   Construction of the Calibration Model for Near-infrared Spectral Analysis of Complex Samples [J].
Hao Yong ;
Cai Wen-Sheng ;
Shao Xue-Guang .
CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2009, 30 (01) :28-31
[34]   Model-based clustering of high-dimensional data: A review [J].
Bouveyron, Charles ;
Brunet-Saumard, Camille .
COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2014, 71 :52-78
[35]   Model selection in high-dimensional noisy data: a simulation study [J].
Romeo, Giovanni ;
Thoresen, Magne .
JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2019, 89 (11) :2031-2050
[36]   Repeated Sieving for Prediction Model Building with High-Dimensional Data [J].
Liu, Lu ;
Jung, Sin-Ho .
JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (07)
[37]   CALIBRATION OF THE SPECTRAL SENSITIVITY OF INSTRUMENTS FOR THE NEAR INFRARED REGION [J].
Parfenov, P. S. ;
Litvin, A. P. ;
Baranov, A. V. ;
Veniaminov, A. V. ;
Ushakova, E. V. .
JOURNAL OF APPLIED SPECTROSCOPY, 2011, 78 (03) :433-439
[38]   Calibration of the spectral sensitivity of instruments for the near infrared region [J].
P. S. Parfenov ;
A. P. Litvin ;
A. V. Baranov ;
A. V. Veniaminov ;
E. V. Ushakova .
Journal of Applied Spectroscopy, 2011, 78 :433-439
[39]   Applying multivariate techniques to high-dimensional temporally correlated fMRI data [J].
Adolf, Daniela ;
Baecke, Sebastian ;
Kahle, Waltraud ;
Bernarding, Johannes ;
Kropf, Siegfried .
JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2011, 141 (12) :3760-3770
[40]   Non-negative Constrained Penalty for High-Dimensional Correlated Data [J].
Ming, Hao ;
Chen, Yinjun ;
Yang, Hu .
COMMUNICATIONS IN MATHEMATICS AND STATISTICS, 2025,