Mechanical failure of total hip arthroplasties and associated risk factors

被引:3
作者
Baecker, Henrik C. [1 ]
Wu, Chia H. [2 ]
Kienzle, Arne [1 ]
Perka, Carsten [1 ]
Gwinner, Clemens [1 ]
机构
[1] Charite, Univ Hosp Berlin, Dept Orthopaed Surg & Traumatol, Charitepl 1, D-10117 Berlin, Germany
[2] Baylor Coll Med, Dept Orthoped & Sports Med, Med Ctr, Houston, TX 77030 USA
关键词
Arthroplasty; Hip; THA; Failure; Complication; Outcome; TITANIUM IMPLANTS; FATIGUE;
D O I
10.1007/s00402-022-04353-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Mechanical failure of total hip arthroplasties is a rare but devastating complication. With increasing numbers in primary arthroplasty implantation, revision surgeries are indicated more often. Therefore, understanding the mechanism and the location of failure is essential in determining proper treatment. Aim of this study was to identify mechanical failures of all total hip arthroplasties performed in a major academic center as well as the associated risk factors such as BMI and sports. Methods A retrospective trial was conducted using our prospective arthroplasty database. Database was searched for all patients presenting with mechanical failures of total hip arthroplasty (THA) to the emergency department between 2011 and 2019. All medical charts and radiographs as well as surgical reports were analyzed to identify demographics, implant choice in addition to location of failure and subsequent treatment. Results In total, 13 patients suffering from mechanical total hip implant failure were found. The femoral neck (conus) was broken in four patients, the stem in five cases, one broken inlay, two cup failures and one conus dislocation. The mean BMI was 31.42 +/- 5.29 kg/m(2) including five patients who have obesity class II. In all cases, revision surgeries were indicated. No structural causes or underlying risk factors such as repeated physical load (i.e. in sports) were identified. Conclusion Implant failure does not seem to correlate with participation in sports or BMI. Catastrophic failure of implants is a technical challenge requiring special extraction instruments that can be difficult even for experienced surgeons. It should be noted that functional outcome is often worse for this group of patients after surgery than comparing against those revised for loosening.
引用
收藏
页码:1061 / 1069
页数:9
相关论文
共 24 条
  • [1] The effect of sandblasting treatment on endurance properties of titanium alloy hip prostheses
    Baleani, M
    Viceconti, M
    Toni, A
    [J]. ARTIFICIAL ORGANS, 2000, 24 (04) : 296 - 299
  • [2] Hip joint contact forces during stumbling
    Bergmann, G
    Graichen, F
    Rohlmann, A
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) : 53 - 59
  • [3] Total hip replacement in morbidly obese patients with osteoarthritis RESULTS OF A PROSPECTIVELY MATCHED STUDY
    Chee, Y. H.
    Teoh, K. H.
    Sabnis, B. M.
    Ballantyne, J. A.
    Brenkel, I. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08): : 1066 - 1071
  • [4] Mid term results with the curved modular tapered, fluted titanium Revitan stem in revision hip replacement
    Fink, B.
    Urbansky, K.
    Schuster, P.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (07) : 889 - 895
  • [5] Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    Grupp, Thomas M.
    Weik, Thomas
    Bloemer, Wilhelm
    Knaebel, Hanns-Peter
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [6] Haynes J, 2017, BONE JOINT J, V99B, P31, DOI [10.1302/0301-620X.99B1.BJJ-2016-0346.R1, 10.1302/0301-620x.99b1.bjj-2016-0346.r1]
  • [7] Huber G, 2009, ORTHOPADE, V38, P622, DOI 10.1007/s00132-009-1442-6
  • [8] IL: American Academy of Orthopaedic Surgeons (AAOS), 2020, 2020 ANN REP
  • [9] Jansson, 2020, JAHRESBERICHT 2020 M
  • [10] Athletic activity after lower limb arthroplasty A SYSTEMATIC REVIEW OF CURRENT EVIDENCE
    Jassim, S. S.
    Douglas, S. L.
    Haddad, F. S.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (07) : 923 - 927