The Role and Limitations of the Reference Interval Within Clinical Chemistry and Its Reliability for Disease Detection

被引:4
|
作者
Timbrell, Nathan E. [1 ]
机构
[1] Guys & St Thomas Hosp NHS Trust, Nutristasis Unit, Synnovis, London, England
关键词
clinical chemistry; reference intervals; reference ranges; normal range; clinical decision curve; ANALYTIC COMPONENTS; SERUM CONSTITUENTS; GENDER DYSPHORIA; LONG-TERM; ASSOCIATION; AGE; RECOMMENDATIONS; PREGNANCY; DIAGNOSIS; HEALTH;
D O I
10.3389/bjbs.2024.12339
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Reference intervals (RIs) are a range of values that are supplied alongside laboratory measurements for comparison to allow interpretation of this data. Historically, RIs were referred to as the normal range. However, the perception of what is normal can lead to confusion in clinicians and unnecessary emotional distress in patients. RIs can be acquired using several methods. Laboratories may quote published studies or derive their own using established direct or indirect methods. Alternatively, laboratories may verify RIs provided by assay manufacturers using in-house studies. RIs have several limitations that clinicians should be aware of. The statistical methodology associated with establishment of RIs means that approximately 5% of "disease free" individuals will fall outside the RI. Additionally, the higher the number of tests requested, the higher the probability that one will be abnormal, and repeat results in an individual may show regression to the mean. Completion of studies for establishment of RIs can be expensive, difficult, and time consuming. Method bias and differences in populations can greatly influence RIs and prevent them from being transferable between some laboratories. Differences in individual characteristics such as age, ethnicity, and sex can result in large variation in some analytes. Some patients, such as those whose gender differs from that which was presumed for them at birth, may require their own RIs. Alternatively, a decision will need to be made about which to use. Overall, the issue common to these factors lies within interpretation. As such, RIs can be improved with better training in their use, combined with a better understanding of influences that affect them, and more transparent communication from laboratories in how RIs were derived.
引用
收藏
页数:12
相关论文
共 19 条
  • [1] A Review of the Role of Ultrasound Radiomics and Its Application and Limitations in the Investigation of Thyroid Disease
    Lu, Wen-Wu
    Zhang, Di
    Ni, Xue-Jun
    MEDICAL SCIENCE MONITOR, 2022, 28
  • [2] Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study
    Lee, Jiwon
    Hong, Sangkyoon
    Kim, Nan Young
    Cho, Yonggeun
    Kim, Han-Sung
    Kang, Hee Jung
    Lee, Young Kyoung
    Kim, Miyoung
    CLINICAL LABORATORY, 2023, 69 (03) : 592 - 603
  • [3] Clinical utility of personalized reference intervals for CEA in the early detection of oncologic disease
    Martinez-Espartosa, Debora
    Alegre, Estibaliz
    Casero-Ramirez, Hugo
    Diaz-Garzon, Jorge
    Fernandez-Calle, Pilar
    Fuentes-Bullejos, Patricia
    Varo, Nerea
    Gonzalez, Alvaro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025, 63 (02) : 376 - 386
  • [4] Reference intervals for eight enzymes in blood of adult females and males measured in accordance with the International Federation of Clinical Chemistry reference system at 37°C:: part of the Nordic Reference Interval Project
    Stromme, JH
    Rustad, P
    Steensland, H
    Theodorsen, L
    Urdal, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2004, 64 (04): : 371 - 383
  • [5] Canadian Laboratory Initiative on Pediatric Reference Interval Database (CALIPER): Pediatric reference intervals for an integrated clinical chemistry and immunoassay analyzer, Abbott ARCHITECT ci8200
    Chan, Man Khun
    Seiden-Long, Isolde
    Aytekin, Mujdat
    Quinn, Frank
    Ravalico, Tricia
    Ambruster, David
    Adeli, Khosrow
    CLINICAL BIOCHEMISTRY, 2009, 42 (09) : 885 - 891
  • [6] Detection of ADTRP in circulation and its role as a novel biomarker for coronary artery disease
    Ooi, Delicia Shu Qin
    Ong, Sze Min
    Eng, Ming Hui
    Chan, Yiong Huak
    Lee, Yung Seng
    Low, Adrian Fatt Hoe
    Chan, Mark Yan-Yee
    Heng, Chew-Kiat
    PLOS ONE, 2020, 15 (08):
  • [7] The natural history of QTc interval and its clinical impact in coronavirus disease 2019 survivors after 1 year
    Mojon-Alvarez, Diana
    Izquierdo, Andrea
    Cubero-Gallego, Hector
    Calvo-Fernandez, Alicia
    Marrugat, Jaume
    Perez-Fernandez, Silvia
    Cabero, Paula
    Sola-Richarte, Claudia
    Soler, Cristina
    Farre, Nuria
    Vaquerizo, Beatriz
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [8] The role of the Clinical Chemistry laboratory in facilitating earlier diagnosis of dyslipidaemia-associated inherited metabolic disease
    Reeve, Janice L., V
    Twomey, Patrick J.
    Borovickova, Ingrid
    JOURNAL OF CLINICAL PATHOLOGY, 2020, 73 (07) : 363 - 365
  • [9] Exploring the role of anticipatory postural adjustment duration within APA2 subphase as a potential mediator between clinical disease severity and fall risk in Parkinson's disease
    Hu, Cheng-Hao
    Lai, Yun-Ru
    Huang, Chih-Cheng
    Lien, Chia-Yi
    Chen, Yueh-Sheng
    Yu, Chiun-Chieh
    Lee, Sieh-Yang
    Lin, Wei-Che
    Cheng, Ben-Chung
    Chiu, Wen-Chan
    Chiang, Yi-Fang
    Kung, Chien-Feng
    Lu, Cheng-Hsien
    FRONTIERS IN AGING NEUROSCIENCE, 2024, 16
  • [10] Role of Multimodality Imaging in Gastroesophageal Reflux Disease and Its Complications, with Clinical and Pathologic Correlation
    Manning, Maria A.
    Shafa, Shervin
    Mehrotra, Anupamjit K.
    Grenier, Rachel E.
    Levy, Angela D.
    RADIOGRAPHICS, 2020, 40 (01) : 44 - 71