Towards in-field assessment of humeral and scapular kinematics: a comparison between laboratory and field settings using inertial sensors

被引:0
|
作者
Lordall, Jackson [1 ]
Akinluyi, Opeyemi Vincent [1 ]
Lang, Angelica E. [1 ]
机构
[1] Univ Saskatchewan, Coll Med, Canadian Ctr Rural & Agr Hlth, Saskatoon, SK, Canada
来源
关键词
wearable sensors; shoulder; home; work; sport; humeral elevation; humeral axial rotation; scapular upward rotation; SHOULDER; ORIENTATION; MOTION; TRUNK; ELBOW; ARM; INDIVIDUALS; VARIABILITY; RELIABILITY; DYSKINESIS;
D O I
10.3389/fspor.2024.1349570
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Introduction Inertial measurement units allow for quantitative assessment of body motion in many environments. Determining the ability to measure upper limb motion with inertial measurement units, leveraging procedures traditionally used in the lab such as scapular calibration procedures and humeral axial rotation calculation, would expand the opportunities to assess upper limb function in externally valid environments. This study examined if humeral and scapular motion measured in different field settings is consistent with motion measured in a lab setting in similar tasks.Methods Twenty-eight adults participated in the study (14 field setting, 14 lab setting). Three different types of field settings were included: home (n = 5), work (n = 4), and sports (n = 5). Field participants were matched to lab participants based on sex and body height. All participants were equipped with five inertial and magnetic measurement units (Xsens Awinda, Xsens Technlogies, NL, Fs = 100 Hz) on the torso, humeri, and scapulae. Humeral and scapular angles were measured during a functional task protocol consisting of seven tasks. Data from all three field settings were combined. Statistical parametric mapping (alpha = .05) was used to assess differences in waveforms between the lab and field data.Results and discussion Five out of seven tasks displayed no differences for humeral elevation and humeral axial rotation, while scapular upward rotation and tilt were not statistically different for any tasks. Scapular internal rotation variability was very high for the field setting, but not for the lab setting. Task-based differences in humeral elevation and humeral axial rotation may be related to equipment modifications for the field protocol and between subjects' variability in task performance. Data indicate that humeral elevation, humeral axial rotation, and scapular upward rotation can be measured in externally valid field settings, which is promising for the evaluation of upper limb movement in natural environments.
引用
收藏
页数:10
相关论文
共 16 条
  • [1] Towards In-Field and Online Calibration of Inertial Navigation Systems using Moving Horizon Estimation
    Girrbach, Fabian
    Zandbergen, Raymond
    Kok, Manon
    Hageman, Tijmen
    Bellusci, Giovanni
    Diehl, Moritz
    2019 18TH EUROPEAN CONTROL CONFERENCE (ECC), 2019, : 4338 - 4343
  • [2] A Comparison Between an in-Field and an in-Laboratory 50 km Ultralong Erbium Fiber Laser
    Saito, Lucia A. M.
    de Souza, Eunezio A.
    Romero, Murilo A.
    2009 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1AND 2, 2009, : 785 - +
  • [3] An Investigation of Running Kinematics with Recovered Anterior Cruciate Ligament Reconstruction on a Treadmill and In-Field Using Inertial Measurement Units: A Preliminary Study
    Hill, Matteo
    Kiesewetter, Pierre
    Milani, Thomas L.
    Mitschke, Christian
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [4] Sleep disturbances from road traffic noise:: A comparison between laboratory and field settings
    Skånberg, A
    Öhrström, E
    JOURNAL OF SOUND AND VIBRATION, 2006, 290 (1-2) : 3 - 16
  • [5] Improved vigilance after sodium oxybate treatment in narcolepsy: a comparison between in-field and in-laboratory measurements
    van Schie, Mojca K. M.
    Werth, Esther
    Lammers, Gert Jan
    Overeem, Sebastiaan
    Baumann, Christian R.
    Fronczek, Rolf
    JOURNAL OF SLEEP RESEARCH, 2016, 25 (04) : 486 - 496
  • [6] Direct Kinematic Observation Validation And Comparison Between Field And Laboratory Settings Using Omni Rate Of Perceived Exertion Scale
    Balasekaran, Govindasamy
    Yeow, Rachel Leah
    Cheo, Ng Yew
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 472 - 472
  • [7] Road traffic noise-induced sleep disturbances:: a comparison between laboratory and field settings
    Skånberg, A
    JOURNAL OF SOUND AND VIBRATION, 2004, 277 (03) : 465 - 467
  • [8] A comparison between in-field and in-laboratory 50 km ultralong Erbium-doped fiber lasers actively mode-locked
    Saito, Lucia A. M.
    Thoroh de Souza, E. A.
    OPTICS EXPRESS, 2012, 20 (15): : 17001 - 17009
  • [9] A novel approach to spinal 3-D kinematic assessment using inertial sensors: Towards effective quantitative evaluation of low back pain in clinical settings
    Ashouri, Sajad
    Abedi, Mohsen
    Abdollahi, Masoud
    Manshadi, Farideh Dehghan
    Parnianpour, Mohamad
    Khalaf, Kinda
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 89 : 144 - 149
  • [10] Assessment of seasonality of influenza in swine using field submissions to a diagnostic laboratory in Ontario between 2007 and 2012
    Poljak, Zvonimir
    Carman, Susy
    McEwen, Beverly
    INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2014, 8 (04) : 482 - 492