Machine Log File and Calibration Errors-based Patient-specific Quality Assurance (QA) for Volumetric Modulated Arc Therapy (VMAT)

被引:1
作者
Ma, Yangguang [1 ,2 ]
Mou, Xuanqin [2 ]
Beeraka, Narasimha M. [3 ,4 ]
Guo, Yuexin [1 ]
Liu, Junqi [1 ]
Dai, Jianrong [5 ]
Fan, Ruitai [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiat Oncol, Zhengzhou 450052, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Informat & Commun Engn, Xian 710049, Peoples R China
[3] IM Sechenov First Moscow State Med Univ, Sechenov Univ, Dept Human Anat, Minist Hlth Russian Federat, 8-2 Trubetskaya Str, Moscow 119991, Russia
[4] Raghavendra Inst Pharmaceut Educ & Res RIPER, Chiyyedu 515721, Andhra Pradesh, India
[5] Chinese Acad Med Sci & Peking Union Med Coll, Natl Canc Ctr, Natl Clin Res Ctr Canc, Dept Radiat Oncol,Canc Hosp, Beijing 100021, Peoples R China
关键词
VMAT QA; log file; calibration error; dose reconstruction; cancers; treatment planning system; radiation oncology; LEAF POSITION ACCURACY; MULTILEAF COLLIMATOR; RADIATION-THERAPY; MLC CALIBRATION; VERIFICATION; IMRT; VALIDATION; DETECTOR; DEVICE;
D O I
10.2174/0113816128226519231017050459
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dose reconstructed based on linear accelerator (linac) log-files is one of the widely used solutions to perform patient-specific quality assurance (QA). However, it has a drawback that the accuracy of log-file is highly dependent on the linac calibration. The objective of the current study is to represent a new practical approach for a patient-specific QA during Volumetric modulated arc therapy (VMAT) using both log-file and calibration errors of linac. Methods: A total of six cases, including two head and neck neoplasms, two lung cancers, and two rectal carcinomas, were selected. The VMAT-based delivery was optimized by the TPS of Pinnacle<^>3 subsequently, using Elekta Synergy VMAT linac (Elekta Oncology Systems, Crawley, UK), which was equipped with 80 Multi-leaf collimators (MLCs) and the energy of the ray selected at 6 MV. Clinical mode log-file of this linac was used in this study. A series of test fields validate the accuracy of log-file. Then, six plans of test cases were delivered and log-file of each was obtained. The log-file errors were added to the corresponding plans through the house script and the first reconstructed plan was obtained. Later, a series of tests were performed to evaluate the major calibration errors of the linac (dose-rate, gantry angle, MLC leaf position) and the errors were added to the first reconstruction plan to generate the second reconstruction plan. At last, all plans were imported to Pinnacle and recalculated dose distribution on patient CT and ArcCheck phantom (SUN Nuclear). For the former, both target and OAR dose differences between them were compared. For the latter, gamma was evaluated by ArcCheck, and subsequently, the surface dose differences between them were performed. Results: Accuracy of log-file was validated. If error recordings in the log file were only considered, there were four arcs whose proportion of control points with gantry angle errors more than +/- 1 degrees larger than 35%. Errors of leaves within +/- 0.5 mm were 95% for all arcs. The distinctness of a single control point MU was bigger, but the distinctness of cumulative MU was smaller. The maximum, minimum, and mean doses for all targets were distributed between -6.79E-02-0.42%, -0.38-0.4%, 2.69E-02-8.54E-02% respectively, whereas for all OAR, the maximum and mean dose were distributed between -1.16-2.51%, -1.21-3.12% respectively. For the second reconstructed dose: the maximum, minimum, and mean dose for all targets was distributed between 0.0995 similar to 5.7145%, 0.6892 similar to 4.4727%, 0.5829 similar to 1.8931% separately. Due to OAR, maximum and mean dose distribution was observed between -3.1462 similar to 6.8920%, -6.9899 similar to 1.9316%, respectively. Conclusion: Patient-specific QA based on the log-file could reflect the accuracy of the linac execution plan, which usually has a small influence on dose delivery. When the linac calibration errors were considered, the reconstructed dose was closer to the actual delivery and the developed method was accurate and practical.
引用
收藏
页码:2738 / 2751
页数:14
相关论文
共 31 条
[1]   Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration [J].
Baker, SJK ;
Budgell, GJ ;
MacKay, RI .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1377-1392
[2]   Comprehensive Patient-Specific Intensity-Modulated Radiation Therapy Quality Assurance Comparing Mobius3D/FX to Conventional Methods of Evaluation [J].
Basavatia, Amar K. ;
Fiedler, Derek A. ;
Ritter, Johannes ;
Brodin, Patrik ;
Goddard, Lee C. ;
Jeong, Kyoungkeun ;
Hsu, Shu-Hui ;
Mynampati, Dinesh K. ;
Yaparpalvi, Ravindra ;
Tome, Wolfgang A. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (05)
[3]   Analysis of the measurement precision of an amorphous silicon EPID used for MLC leaf position quality control and the long-term calibration stability of an optically controlled MLC [J].
Budgell, G. J. ;
Clarke, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15) :N297-N306
[4]   Requirements for leaf position accuracy for dynamic multileaf collimation [J].
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brown, KJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1211-1227
[5]   Use of EPID for leaf position accuracy QA of dynamic multi-leaf collimator (DMLC) treatment [J].
Chang, J ;
Obcemea, CH ;
Sillanpaa, J ;
Mechalakos, J ;
Burman, C .
MEDICAL PHYSICS, 2004, 31 (07) :2091-2096
[6]  
Chang L, 2001, J Appl Clin Med Phys, V2, P54, DOI 10.1120/1.1335696
[7]   An improved method to accurately calibrate the gantry angle indicators of the radiotherapy linear accelerators [J].
Chang, Liyun ;
Ho, Sheng-Yow ;
Du, Yi-Chun ;
Lin, Chih-Ming ;
Chen, Tainsong .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (2-3) :441-445
[8]   Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle [J].
Clarke, M. F. ;
Budgell, G. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (02) :473-485
[9]   Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients? [J].
Didona, Annamaria ;
Lancellotta, Valentina ;
Zucchetti, Claudio ;
Panizza, Bianca Moira ;
Frattegiani, Alessandro ;
Iacco, Martina ;
Di Pilato, Anna Concetta ;
Saldi, Simonetta ;
Aristei, Cynthia .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (03) :175-182
[10]   Evaluation of a new VMAT QA device, or the "X" and "O" array geometries [J].
Feygelman, Vladimir ;
Zhang, Geoffrey ;
Stevens, Craig ;
Nelms, Benjamin E. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02) :146-168