Fast 19F spectroscopic imaging with pseudo-spiral k-space sampling

被引:2
作者
Yildirim, Muhammed [1 ,2 ,3 ]
Kovalyk, Xenia [2 ,3 ,4 ]
Scholtz, Patrick [2 ,3 ,4 ]
Schuetz, Markus [2 ,3 ,4 ]
Lindemeyer, Johannes [2 ,3 ,4 ]
Lamerichs, Rolf [5 ]
Gruell, Holger [2 ,3 ,4 ]
Isik, Esin Ozturk [1 ]
机构
[1] Bogazici Univ, Inst Biomed Engn, TR-34684 Istanbul, Turkiye
[2] Univ Cologne, Inst Diagnost & Intervent Radiol, Fac Med, Cologne, Germany
[3] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
[4] Univ Cologne, Fac Math & Nat Sci, Dept Chem, Cologne, Germany
[5] Philips Res, Eindhoven, Netherlands
关键词
F-19; MRI; fast MRSI; fluorine; pseudo-spiral k-space trajectory; spectroscopic imaging; CHEMICAL-SHIFT ARTIFACTS; CELL TRACKING; PERFLUOROCARBON; MRI; INFLAMMATION; PFOB; RECONSTRUCTION;
D O I
10.1002/nbm.5086
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorine MRI is finding wider acceptance in theranostics applications where imaging of (19) F hotspots of fluorinated contrast material is central. The essence of such applications is to capture ghosting-artifact-free images of the inherently low MR response under clinically viable conditions. To serve this purpose, this work introduces the balanced spiral spectroscopic imaging (BaSSI) sequence, which is implemented on a 3.0 T clinical scanner and is capable of generating (19) F hotspot images in an efficient manner. The sequence utilizes an all-phase-encoded pseudo-spiral k-space trajectory, enabling the acquisition of broadband (80 ppm) fluorine spectra free from chemical shift ghosting. BaSSI can acquire a 64 x 64 image with 1 mm x 1 mm voxels in just 14 s, significantly outperforming typical MRSI sequences used in (1) H or (31) P imaging. The study employed in silico characterization to verify essential design choices such as the excitation pulse, as well as to identify the boundaries of the parameter space explored for optimization. BaSSI's performance was further benchmarked against the 3D ultrashort-echo-time balanced steady-state free precession (3D UTE BSSFP) sequence, a well established method used in (19) F MRI, in vitro. Both sequences underwent extensive optimization through exploration of a wide parameter space on a small phantom containing 10 mu L of non-diluted bulk perfluorooctylbromide (PFOB) prior to comparative experiments. Subsequent to optimization, BaSSI and 3D UTE BSSFP were employed to capture images of small non-diluted bulk PFOB samples (0.10 and 0.05 mu L), with variations in the number of signal averages, and thus the total scan time, in order to assess the detection sensitivities of the sequences. In these experiments, the detection sensitivity was evaluated using the Rose criterion (R-c ), which provides a quantitative metric for assessing object visibility. The study further demonstrated BaSSI's utility as a (pre)clinical tool through postmortem imaging of polymer microspheres filled with PFOB in a BALB/c mouse. Anatomic localization of (19) F hotspots was achieved by denoising raw data obtained with BaSSI using a filter based on the Rose criterion. These data were then successfully registered to (1) H anatomical images. BaSSI demonstrated superior detection sensitivity in the benchmarking analysis, achieving R-c values approximately twice as high as those obtained with the 3D UTE BSSFP method. The technique successfully facilitated imaging and precise localization of (19) F hotspots in postmortem experiments. However, it is important to highlight that imaging 10 mM PFOB in small mice postmortem, utilizing a 48 x 48 x 48 3D scan, demanded a substantial scan time of 1 h and 45 min. Further studies will explore accelerated imaging techniques, such as compressed sensing, to enhance BaSSI's clinical utility.
引用
收藏
页数:14
相关论文
共 50 条
[1]   Clinical Cell Therapy Imaging Using a Perfluorocarbon Tracer and Fluorine-19 MRI [J].
Ahrens, Eric T. ;
Helfer, Brooke M. ;
O'Hanlon, Charles F. ;
Schirda, Claudiu .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) :1696-+
[2]   In vivo imaging platform for tracking immunotherapeutic cells [J].
Ahrens, ET ;
Flores, R ;
Xu, HY ;
Morel, PA .
NATURE BIOTECHNOLOGY, 2005, 23 (08) :983-987
[3]  
[Anonymous], 2013, Proc Int Soc Magn Reson Med
[4]   Long-term sequestration of fluorinated compounds in tissues after fluvoxamine or fluoxetine treatment:: a fluorine magnetic resonance spectroscopy study in vivo [J].
Bolo, NR ;
Hodé, Y ;
Macher, JP .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) :268-276
[5]  
Bolo NR., 1997, P INT SOC MAGN RESON, V5, P1431
[6]   FAST PERFLUOROCARBON IMAGING USING F-19 U-FLARE [J].
BORNERT, P ;
NORRIS, DG ;
KOCH, H ;
DREHER, W ;
REICHELT, H ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) :226-234
[7]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[8]   DECONVOLUTION TECHNIQUES FOR REMOVING THE EFFECTS OF CHEMICAL-SHIFT IN F-19 NUCLEAR-MAGNETIC-RESONANCE IMAGING OF PERFLUOROCARBON COMPOUNDS [J].
BUSSE, LJ ;
THOMAS, SR ;
PRATT, RG ;
CLARK, LC ;
ACKERMAN, JL ;
SAMARATUNGA, RC ;
HOFFMANN, RE .
MEDICAL PHYSICS, 1986, 13 (04) :518-524
[9]   Perfluorocarbon-loaded micro and nanosystems for medical imaging: A state of the art [J].
Cosco, Donato ;
Fattal, Elias ;
Fresta, Massimo ;
Tsapis, Nicolas .
JOURNAL OF FLUORINE CHEMISTRY, 2015, 171 :18-26
[10]   Compressed sensing with signal averaging for improved sensitivity and motion artifact reduction in fluorine-19 MRI [J].
Darcot, Emeline ;
Yerly, Jerome ;
Hilbert, Tom ;
Colotti, Roberto ;
Najdenovska, Elena ;
Kober, Tobias ;
Stuber, Matthias ;
van Heeswijk, Ruud B. .
NMR IN BIOMEDICINE, 2021, 34 (01)