A novel artificial neural network approach for residual life estimation of paper insulation in oil-immersed power transformers

被引:1
|
作者
Nezami, Md. Manzar [1 ]
Equbal, Md. Danish [2 ]
Ansari, Md. Fahim [3 ]
Alotaibi, Majed A. [4 ]
Malik, Hasmat [3 ,5 ]
Marquez, Fausto Pedro Garcia [6 ]
Hossaini, Mohammad Asef [7 ]
机构
[1] GLA Univ, Dept Elect & Commun Engn, Mathura, India
[2] Galgotias Coll Engn & Technol, Dept Elect Engn, Greater Noida, India
[3] Graph Era Deemed Univ, Dept Elect Engn, Dehra Dun, India
[4] King Saud Univ, Coll Engn, Dept Elect Engn, Riyadh, Saudi Arabia
[5] Univ Teknol Malaysia, Fac Elect Engn, Dept Elect Power Engn, Johor Baharu, Malaysia
[6] Univ Castilla La Mancha, Ingenium Res Grp, Ciudad Real, Spain
[7] Badghis Univ, Dept Phys, Badghis, Afghanistan
关键词
condition monitoring; fault diagnosis; neural nets; power transformer insulation; power transformers; remaining life assessment; IMPREGNATED PAPER; DISSOLVED-GASES; DEGRADATION; MOISTURE; IDENTIFICATION; SYSTEM;
D O I
10.1049/elp2.12407
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Avoiding financial losses requires preventing catastrophic oil-filled power transformer breakdowns. Continuous online transformer monitoring is needed. The authors use paper insulation to evaluate transformer health for continuous online transformer monitoring. The study suggests a new artificial intelligence method for estimating paper insulation residual life in oil-immersed power transformers. The four artificial intelligence models use backpropagation-based neural networks to predict paper insulation lifespan. Four primary transformer insulating paper failure indices-degree of polymerisation, 2-furfuraldehyde, carbon monoxide, and carbon dioxide-form the basis of these models. Each model, including the backpropagation-based neural networks, estimates paper insulation life using one failure index, along with moisture and temperature data. Optimisation techniques enhance hidden layer neurons and epoch count for improved performance. Results are validated against literature-based life models, establishing a precise input-output correlation. This method accurately predicts the remaining useable life of power transformer paper insulation, enabling utilities to take proactive measures for safe and efficient transformer operation. The novelties of the study are: (1) The development of AI model for residual life estimation of paper insulation in oil-immersed power transformer, (2) the proposed model is developed based on data-driven methodology, (3) the results demonstration is based on experimental dataset, which is highly acceptable.image
引用
收藏
页码:477 / 488
页数:12
相关论文
共 15 条
  • [1] Experimental Studies on the Estimated Life of Oil-Immersed Insulation Paper in Traction Transformers
    Zhou, Lijun
    Liao, Wei
    Wang, Dongyang
    Cui, Yi
    Wang, Lujia
    Zhang, Liqing
    Guo, Lei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 2646 - 2657
  • [2] Application of back propagation neural network in complex diagnostics and forecasting loss of life of cellulose paper insulation in oil-immersed transformers
    Ngwenyama, M. K.
    Gitau, M. N.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] A novel fuzzy approach for winding paper insulation health monitoring of oil-immersed power transformer using non-destructive failure parameters
    Nezami, Md. Manzar
    Hashem, Hythem
    Equbal, Md. Danish
    Khan, Shakeb A.
    Malik, Hasmat
    Marquez, Fausto Pedro Garcia
    Afthanorhan, Asyraf
    Hossaini, Mohammad Asef
    IET ELECTRIC POWER APPLICATIONS, 2025, 19 (01)
  • [4] Kolmogorov-Arnold Network in the Fault Diagnosis of Oil-Immersed Power Transformers
    Cabral, Thales W.
    Gomes, Felippe V.
    de Lima, Eduardo R.
    Filho, Jose C. S. S.
    Meloni, Luis G. P.
    SENSORS, 2024, 24 (23)
  • [5] A Dynamic Adam Based Deep Neural Network for Fault Diagnosis of Oil-Immersed Power Transformers
    Ou, Minghui
    Wei, Hua
    Zhang, Yiyi
    Tan, Jiancheng
    ENERGIES, 2019, 12 (06)
  • [6] Raman Spectral Characteristics of Oil-Paper Insulation and Its Application to Ageing Stage Assessment of Oil-Immersed Transformers
    Zou, Jingxin
    Chen, Weigen
    Wan, Fu
    Fan, Zhou
    Du, Lingling
    ENERGIES, 2016, 9 (11)
  • [7] Fault diagnosis of oil-immersed power transformers using common vector approach
    Kirkbas, Ali
    Demircali, Akif
    Koroglu, Selim
    Kizilkaya, Aydin
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184
  • [8] Influence of the antioxidant on the long-term ageing characteristics of oil-paper insulation and the deposition and migration of copper sulphide in oil-immersed transformers
    Yang, Lijun
    Gao, Sihang
    Li, Jinzhong
    Sun, Weidong
    IET ELECTRIC POWER APPLICATIONS, 2016, 10 (07) : 675 - 680
  • [9] Application of neuro-fuzzy scheme to investigate the winding insulation paper deterioration in oil-immersed power transformer
    Malik, Hasmat
    Yadav, Amit Kumar
    Mishra, Sukumar
    Mehto, Tarkeshwar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 256 - 271
  • [10] Oil-immersed power transformer internal fault diagnosis research based on probabilistic neural network
    Yu, Shenghao
    Zhao, Dongming
    Chen, Wei
    Hou, Hui
    7TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT 2016) / THE 6TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2016) / AFFILIATED WORKSHOPS, 2016, 83 : 1327 - 1331