Hepatic fat quantification in dual-layer computed tomography using a three-material decomposition algorithm

被引:6
|
作者
Demondion, Emilie [1 ]
Ernst, Olivier [1 ]
Louvet, Alexandre [2 ]
Robert, Benjamin [3 ]
Kafri, Galit [4 ]
Langzam, Eran [4 ]
Vermersch, Mathilde [1 ,5 ]
机构
[1] Lille Univ Hosp, Med Imaging Dept, 2 Ave Oscar Lambret, Lille, France
[2] Lille Univ Hosp, Dept Gastroenterol & Hepatol, 2 Ave Oscar Lambret, Lille, France
[3] Philips Healthcare, CT Clin Sci, Paris, France
[4] Philips Healthcare, CT Clin Sci, Haifa, Israel
[5] Valenciennes Hosp Ctr, Med Imaging Dept, 114 Ave Desandrouin, Valenciennes, France
关键词
Fatty liver; Non-alcoholic fatty liver disease; Radiography (dual-energy scanned projection); Tomography (X-ray computed); MULTIMATERIAL DECOMPOSITION; CT; ASSOCIATION; STEATOSIS; FRACTION; MRI;
D O I
10.1007/s00330-023-10382-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe purpose of this study was to evaluate a three-material decomposition algorithm for hepatic fat quantification using a dual-layer computed tomography (DL-CT) and MRI as reference standard on a large patient cohort.MethodA total of 104 patients were retrospectively included in our study, i.e., each patient had an MRI exam and a DL-CT exam in our institution within a maximum of 31 days. Four regions of interest (ROIs) were positioned blindly and similarly in the liver, by two independent readers on DL-CT and MRI images. For DL-CT exams, all imaging phases were included. Fat fraction agreement between CT and MRI was performed using intraclass correlation coefficients (ICC), determination coefficients R2, and Bland-Altman plots. Diagnostic performance was determined using sensitivity, specificity, and positive and negative predictive values. The cutoff for steatosis was 5%.ResultsCorrelation between MRI and CT data was excellent for all perfusion phases with ICC calculated at 0.99 for each phase. Determination coefficients R2 were also good for all perfusion phases (about 0.95 for all phases). Performance of DL-CT in the diagnosis of hepatic steatosis was good with sensitivity between 89 and 91% and specificity ranging from 75 to 80%, depending on the perfusion phase. The positive predictive value was ranging from 78 to 93% and the negative predictive value from 82 to 86%.ConclusionMulti-material decomposition in DL-CT allows quantification of hepatic fat fraction with a good correlation to MRI data.Clinical relevance statementThe use of DL-CT allows for detection of hepatic steatosis. This is especially interesting as an opportunistic finding CT performed for other reasons, as early detection can help prevent or slowdown the development of liver metabolic disease.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.
引用
收藏
页码:3708 / 3718
页数:11
相关论文
共 50 条
  • [41] Dual Energy Computed Tomography Collagen Material Decomposition for Detection of Lumbar Spine Disc Extrusion and Sequestration: A Comparative Study With Greyscale Computed Tomography
    Abdellatif, Waleed
    Nugent, James P. P.
    Alballa, Faisal
    Murray, Nicolas
    Jalal, Sabeena
    Ali, Ismail T. T.
    Nicolaou, Savvas
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2023, 74 (01): : 110 - 118
  • [42] Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images
    Sauter, Andreas P.
    Muenzel, Daniela
    Dangelmaier, Julia
    Braren, Rickmer
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    Fingerle, Alexander A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 108 - 114
  • [43] Image Decomposition Algorithm for Dual-Energy Computed Tomography via Fully Convolutional Network
    Xu, Yifu
    Yan, Bin
    Zhang, Jingfang
    Chen, Jian
    Zeng, Lei
    Wang, Linyuang
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2018, 2018
  • [44] Quantitative evaluation of myelosuppression after chemotherapy for patients with ovarian cancer using material decomposition in dual-energy computed tomography
    Bai, Wanjing
    Li, Lin
    Ning, Gang
    Li, Xuesheng
    Chen, Xijian
    Jiang, Lingjun
    Yang, Xueru
    Zhou, Hanhong
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2023, 44 (01) : 79 - 86
  • [45] Iodine Quantification Using Dual-Energy Computed Tomography for Differentiating Thymic Tumors
    Yan, Wei-Qiang
    Xin, Yong-Kang
    Jing, Yong
    Li, Gang-Feng
    Wang, Shu-Mei
    Rong, Wei-Cheng
    Xiao, Gang
    Lei, Xue-Bin
    Li, Bo
    Hu, Yu-Chuan
    Cui, Guang-Bin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 873 - 880
  • [46] Reproducibility of myocardial extracellular volume quantification using dual-energy computed tomography in patients with cardiac amyloidosis
    Kadoya, Yoshito
    Omaygenc, Mehmet Onur
    Chow, Benjamin
    Small, Gary R.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2025, 19 (01) : 74 - 80
  • [47] Assessing the Sensitivity of Dual-Energy Computed Tomography 3-Material Decomposition for the Detection of Gout
    Tse, Justin J.
    Kondro, Douglas A.
    Kuczynski, Michael T.
    Pauchard, Yves
    Veljkovic, Andrea
    Holdsworth, David W.
    Frasson, Viviane
    Manske, Sarah L.
    MacMullan, Paul
    Salat, Peter
    INVESTIGATIVE RADIOLOGY, 2022, 57 (09) : 613 - 619
  • [48] Material decomposition for simulated dual-energy breast computed tomography via hybrid optimization method
    Komolafe, Temitope E.
    Du, Qiang
    Zhang, Yin
    Wu, Zhongyi
    Zhang, Cheng
    Li, Ming
    Zheng, Jian
    Yang, Xiaodong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1037 - 1054
  • [49] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Haenghwa Lee
    Hee-Joung Kim
    Donghoon Lee
    Dohyeon Kim
    Seungyeon Choi
    Minjae Lee
    Journal of the Korean Physical Society, 2020, 77 : 515 - 523
  • [50] Application of Dual-Layer Spectral-Detector Computed Tomography Angiography in Identifying Symptomatic Carotid Atherosclerosis: A Prospective Observational Study
    Zhang, Jia
    Li, Sijia
    Wu, Lei
    Wang, Haoyuan
    Wang, Chuanying
    Zhou, Yinan
    Sui, Binbin
    Zhao, Xingquan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (06):