Hepatic fat quantification in dual-layer computed tomography using a three-material decomposition algorithm

被引:6
|
作者
Demondion, Emilie [1 ]
Ernst, Olivier [1 ]
Louvet, Alexandre [2 ]
Robert, Benjamin [3 ]
Kafri, Galit [4 ]
Langzam, Eran [4 ]
Vermersch, Mathilde [1 ,5 ]
机构
[1] Lille Univ Hosp, Med Imaging Dept, 2 Ave Oscar Lambret, Lille, France
[2] Lille Univ Hosp, Dept Gastroenterol & Hepatol, 2 Ave Oscar Lambret, Lille, France
[3] Philips Healthcare, CT Clin Sci, Paris, France
[4] Philips Healthcare, CT Clin Sci, Haifa, Israel
[5] Valenciennes Hosp Ctr, Med Imaging Dept, 114 Ave Desandrouin, Valenciennes, France
关键词
Fatty liver; Non-alcoholic fatty liver disease; Radiography (dual-energy scanned projection); Tomography (X-ray computed); MULTIMATERIAL DECOMPOSITION; CT; ASSOCIATION; STEATOSIS; FRACTION; MRI;
D O I
10.1007/s00330-023-10382-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe purpose of this study was to evaluate a three-material decomposition algorithm for hepatic fat quantification using a dual-layer computed tomography (DL-CT) and MRI as reference standard on a large patient cohort.MethodA total of 104 patients were retrospectively included in our study, i.e., each patient had an MRI exam and a DL-CT exam in our institution within a maximum of 31 days. Four regions of interest (ROIs) were positioned blindly and similarly in the liver, by two independent readers on DL-CT and MRI images. For DL-CT exams, all imaging phases were included. Fat fraction agreement between CT and MRI was performed using intraclass correlation coefficients (ICC), determination coefficients R2, and Bland-Altman plots. Diagnostic performance was determined using sensitivity, specificity, and positive and negative predictive values. The cutoff for steatosis was 5%.ResultsCorrelation between MRI and CT data was excellent for all perfusion phases with ICC calculated at 0.99 for each phase. Determination coefficients R2 were also good for all perfusion phases (about 0.95 for all phases). Performance of DL-CT in the diagnosis of hepatic steatosis was good with sensitivity between 89 and 91% and specificity ranging from 75 to 80%, depending on the perfusion phase. The positive predictive value was ranging from 78 to 93% and the negative predictive value from 82 to 86%.ConclusionMulti-material decomposition in DL-CT allows quantification of hepatic fat fraction with a good correlation to MRI data.Clinical relevance statementThe use of DL-CT allows for detection of hepatic steatosis. This is especially interesting as an opportunistic finding CT performed for other reasons, as early detection can help prevent or slowdown the development of liver metabolic disease.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.
引用
收藏
页码:3708 / 3718
页数:11
相关论文
共 50 条
  • [21] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Lee, Haenghwa
    Kim, Hee-Joung
    Lee, Donghoon
    Kim, Dohyeon
    Choi, Seungyeon
    Lee, Minjae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (06) : 515 - 523
  • [22] Differentiation of Intracerebral Tumor Entities with Quantitative Contrast Attenuation and Iodine Mapping in Dual-Layer Computed Tomography
    Borggrefe, Jan
    Gebest, Max Philipp
    Hauger, Myriam
    Ruess, Daniel
    Mpotsaris, Anastasios
    Kabbasch, Christoph
    Pennig, Lenhard
    Laukamp, Kai Roman
    Goertz, Lukas
    Kroeger, Jan Robert
    Doerner, Jonas
    DIAGNOSTICS, 2022, 12 (10)
  • [23] Accuracy of Dual-Energy Computed Tomography Techniques for Fat Quantification in Comparison With Magnetic Resonance Proton Density Fat Fraction and Single-Energy Computed Tomography in an Anthropomorphic Phantom Environment
    Wu, Zi Jun
    Hippe, Daniel S.
    Zamora, David A.
    Briller, Noah
    Amin, Kathan A.
    Kolokythas, Orpheus
    Mileto, Achille
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) : 877 - 887
  • [24] Feasibility study of three-material decomposition in dual-energy cone-beam CT imaging with deep learning
    Zhu, Jiongtao
    Su, Ting
    Zhang, Xin
    Yang, Jiecheng
    Mi, Donghua
    Zhang, Yunxin
    Gao, Xiang
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14)
  • [25] Plantar Plate Tear Diagnosis Using Dual-Energy Computed Tomography Collagen Material Decomposition Application
    Stevens, Christopher J.
    Murphy, Darra T.
    Korzan, Jeffrey R.
    Nicolaou, Savvas
    Munk, Peter L.
    Ouellette, Hugue
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 478 - 480
  • [26] Obesity, Hepatic Steatosis, and Their Impact on Fat Infiltration of the Trunk Musculature Using Unenhanced Computed Tomography
    Sebro, Ronnie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (02) : 298 - 301
  • [27] A Fast Algorithm for Estimating Dual Energy Computed Tomography Material Decomposed Sinograms
    Hou Xiaowen
    Teng Yueyang
    Lu Zipeng
    Liu Yujia
    Yang Chaoran
    Kang Yan
    2016 2ND IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATIONS (ICCC), 2016, : 603 - 607
  • [28] Skeletal muscle fat quantification by dual-energy computed tomography in comparison with 3T MR imaging
    Molwitz, I.
    Leiderer, M.
    McDonough, R.
    Fischer, R.
    Ozga, A-K.
    Ozden, C.
    Tahir, E.
    Koehler, D.
    Adam, G.
    Yamamura, J.
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7529 - 7539
  • [29] Dual-layer detector spectral computed tomography quantitative parameters for predicting pathological complete remission after neoadjuvant treatment of breast cancer
    Guo, Shaolan
    Wang, Dandan
    Zhao, Qian
    Bi, Zhao
    Li, Wanhu
    Zhu, Jian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2025, 15 (01) : 149 - 163
  • [30] Spectral imaging with dual-layer spectral detector computed tomography for the detection of perfusion defects in acute coronary syndrome
    Mochizuki, Junji
    Nakaura, Takeshi
    Yoshida, Naofumi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Uetani, Hiroyuki
    Funama, Yoshinori
    Hata, Yoshiki
    Azuma, Minako
    Hirai, Toshinori
    HEART AND VESSELS, 2022, 37 (07) : 1115 - 1124