Frequency of technical success of ultrasound-guided arthrogram injections in children

被引:2
作者
O'Sullivan, Joseph [1 ]
Kim, Helen H. R. [1 ]
Otjen, Jeffrey P. [1 ]
Ngo, Anh-Vu [1 ]
Maloney, Ezekiel [1 ]
Menashe, Sarah J. [1 ]
Iyer, Ramesh S. [1 ]
Thapa, Mahesh [1 ]
机构
[1] Univ Washington, Seattle Childrens Hosp, Dept Radiol, Sch Med, 4800 Sand Point Way NE, Seattle, WA 98105 USA
关键词
Pediatric; Magnetic resonance arthrography; Ultrasound guidance; Shoulder; Elbow; Hip; MAGNETIC-RESONANCE ARTHROGRAPHY; MR ARTHROGRAPHY; 3-T MRI; DIAGNOSTIC PERFORMANCE; FLUOROSCOPIC GUIDANCE; JOINT INJECTIONS; SHOULDER; HIP;
D O I
10.1007/s00247-023-05777-5
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundMR arthrography is an essential diagnostic tool to assess and guide management of labral, ligamentous, fibrocartilaginous, and capsular abnormalities in children. While fluoroscopy is traditionally used for intra-articular contrast administration, ultrasound offers advantages of portability and lack of ionizing radiation exposure for both the patient and proceduralist.ObjectiveThe purpose of this retrospective study is to quantify technical success and frequency of complications of ultrasound-guided arthrogram injections at our institution.Materials and methodsThis retrospective analysis investigates the results of 217 ultrasound-guided arthrograms of the shoulder, elbow, and hip in patients aged 5-18 years. Successful injection of contrast into the target joint, clinical indication for MR arthrography, and complications were reviewed.ResultsAccurate ultrasound-guided intra-articular administration of contrast into the target joint was successful for 100% of shoulder cases (90/90), 97% of elbow cases (77/79), and 98% of hip cases (47/48). Leak of contrast outside the target joint occurred in 1.4% (3/217) of cases. No major side effects including excessive bleeding, paresthesia, allergic reactions, or infection occurred during or after the procedure. Additionally, no major vessel, nerve, or tendon complications were observed on MR images.ConclusionUltrasound guidance is a reliable, effective, and safe approach to arthrography in children.
引用
收藏
页码:2380 / 2385
页数:6
相关论文
共 24 条
  • [1] ShoulderMRArthrography: Comparative Evaluation of Three Different Contrast Injection Techniques Using an Anterior Approach
    Ali, Abeer H.
    Said, Hatem G.
    Elhamd, Eman Abo
    Mahmoud, Mohammad K.
    Qenawy, Omran K.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (02) : 481 - 490
  • [2] Ultrasound-Guided Hip Injections: A Comparative Study With Fluoroscopy-Guided Injections
    Byrd, J. W. Thomas
    Potts, Elizabeth A.
    Allison, Rachel K.
    Jones, Kay S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01) : 42 - 46
  • [3] Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip
    Chopra, A.
    Grainger, A. J.
    Dube, B.
    Evans, R.
    Hodgson, R.
    Conroy, J.
    Macdonald, D.
    Robinson, Philip
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (03) : 963 - 971
  • [4] Ultrasound-Guided Gadolinium Joint Injections for Magnetic Resonance Arthrography
    Choudur, Hema Nalini
    Ellins, Mary Lou
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2011, 39 (01) : 6 - 11
  • [5] The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement
    Crespo-Rodriguez, Ana
    De Lucas-Villarrubia, Jose
    Pastrana-Ledesma, Miguel
    Hualde-Juvera, Ana
    Mendez-Alonso, Santiago
    Padron, Mario
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 109 - 116
  • [6] Arthrography of the shoulder:: A simple fluoroscopically guidedapproach for targeting the rotator cuff interval
    Dépelteau, H
    Bureau, NJ
    Cardinal, E
    Aubin, B
    Brassard, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) : 329 - 332
  • [7] Retrospective Analysis of the Accuracy of Ultrasound-Guided Magnetic Resonance Arthrogram Injections of the Hip in the Office Setting
    Jernick, Michael
    Gallego, Edward Walker
    Nuzzo, Michael
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2017, 5 (12):
  • [8] Accuracy of shoulder joint injections with ultrasound guidance: Confirmed by magnetic resonance arthrography
    Kuratani, Kosuke
    Tanaka, Makoto
    Hanai, Hiroto
    Hayashida, Kenji
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (03): : 259 - 266
  • [9] Accuracy of 3-T MR Arthrography Versus Conventional 3-T MRI of Elbow Tendons and Ligaments Compared With Surgery
    Magee, Thomas
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : W70 - W75
  • [10] 3-T MRI of the Shoulder: Is MR Arthrography Necessary?
    Magee, Thomas
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (01) : 86 - 92